Detailed instructions for use are in the User's Guide.
[. . . ] Operation of this equipment in a residential area is likely to cause harmful interference, in which case the user will be required to correct the interference at his own expense.
CE Mark Warning
This is a Class B product. In a domestic environment, this product may cause radio interference, in which case the user may be required to take adequate measures.
VCCI Class B Compliance (Japan)
This is a product of VCCI Class B Compliance
AirLive OV-MCR116 User's Manual
Table of Contents
PREFACE 19" MEDIA CONVERTER CHASSIS SYSTEM PRODUCT FEATURES PRODUCT FEATURES UNPACKING AND INSTALLATION UNPACKING INSTALLATION DECIDING HOW TO INSTALL THE SYSTEM . Mounted to 19-inch standard rack Installing Media Converter Connecting to Power (Power Supply) Installing and Removing the Power Supply 1 1 2 2 3 3 3 3 3 4 5 6 7 7 7 8
UNDERSTANDING LED INDICATORS FRONT PANEL POWER AND FAN LED TECHNICAL SPECIFICATIONS
i AirLive OV-MCR116 User's Manual
Preface
This manual describes how to install and use the 19" Media Converter Chassis System. [. . . ] SPECIFICALLY, THE SITE YOU SELECT SHOULD MEET THE FOLLOWING REQUIREMENTS:
The ambient temperature should be between 32 and 104 degrees Fahrenheit (0 to 40 degrees Celsius). Surrounding electrical devices should not exceed the electromagnetic field (RFC) standards for IEC 801-3, Level 2 (3V/M) field strength. Make sure that the equipment receives adequate ventilation at the rear. Deciding How to Install the System We strongly suggest that you install the chassis first, as this is more convenient for you to install media converters into the chassis with ease. The accessories supplied in the product package includes: rackmount screws(8 pcs) and rackmount brackets(2 pcs). This well-built chassis can be installed in the following ways: . Mounted to 19-inch standard rack Use the rackmount brackets and screws to install the chassis into any EIA 19" standard rack.
3 AirLive OV-MCR116 User's Manual
Step 1:
Attach the brackets to each side of the chassis. Apply four screws to each side and secure them tightly.
Step 2:
Carefully position the chassis into the rack. Align the brackets to the side holes on the rack and use rack screws to secure the chassis with the rack.
Step 3: Proceed to the "Connecting to Power" section. . Installing Media Converter The chassis is equipped with sixteen media converter carriers, each of which is fitted into bays of the chassis. Step 1: To install a media converter module onto the chassis, you have to unscrew the bay cover from the desired bay first. Step 2: Unscrew the hand screw counter clockwise by using hand or screwdriver and pull out the media converter out the carrier as shown below.
Unscrew the hand screw counter clockwise by using hand or screwdriver and pull the media converter module out on the carrier
Step 3:
Carefully slide in the module and fasten the hand screw clockwise by using hand or screwdriver until it is fully and firmly fitted into the slot of the chassis.
4 AirLive OV-MCR116 User's Manual
Insert the media converter module into an available slot and fasten the hand screw clockwise by using hand or screwdriver.
. Connecting to Power (Power Supply) The chassis ships with only one power supply, and a second power supply option is at your discretion. When the chassis is equipped with two power supplies, you can have the following advanced performance. Hot Swappable The design of the power system is based on an idea of providing maximum flexibility and redundancy. In this way, you may remove any of the two power supplies without turning off the system. Redundancy During operation, both power supplies are switched on and share the current load. In case that one of them should fail, the other will instantaneously take 100% of the load without any loss. Similarly, if one power supply is removed from servicing, it can be switched off and removed while the chassis continues functioning. Protection System The power of each converter bay comes from the two shared power supplies. [. . . ] Front Panel There is an array of LED indicators, which provides you with instant feedback on the status of the power and the fan.
1
POWER ON
2
POWER FAIL
FAN FAIL
Power and Fan LED 1/2 Power LED Indicates which the power (fan) is working, depends on where the power supply was installed at the rear. On (Green) Off Power supply feed in No power supply feeding
Power On (Amber) Faulty power supply Fail LED Off Power supply works normally Fan Fail On (Amber) Faulty Fan LED Off Fan works normally
7 AirLive OV-MCR116 User's Manual
Technical Specifications
Chassis System Capacity Material Power Cooling LED Indicators Dimension s Net Weight Sixteen bays for housing up to sixteen media converters Steel One power supply provided, hot-swappable *A second power hot-swappable 2 LEDs for fan status 2 LEDs for power feeding in status 2 LEDs for power supply's power status W415 mm × D 390mm × H89 mm Standard 19" size, 2 U 7. 0kg approx. (*Only one power supply included) supply for load-sharing is optional, also
Two fans mounted together with the power supply or alone at the rear
8 AirLive OV-MCR116 User's Manual
Fan Rated Voltage Speed Air Delivery Noise Level Bearing System Dimensions 12Vdc 3200 RPM +/- 250 RPM 42. 5 CFM per min. [. . . ]