If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual APPLIED ENERGY BRITEX. We hope that this APPLIED ENERGY BRITEX user guide will be useful to you.
Manual abstract: user guide APPLIED ENERGY BRITEXINSTALLATION
Detailed instructions for use are in the User's Guide.
[. . . ] INSTALLATION INSTRUCTIONS
FOR COMPLETE FAN LIGHT KIT
BriteX LoVolt & BriteX Turbo
GENERAL MOUNTING AND SAFETY NOTES
1. WHEN INSTALLING FANS SWITCH OFF MAINS SUPPLY BEFORE MAKING ELECTRICAL CONNECTIONS. [. . . ] Note: a means for disconnection in all poles must be incorporated in the fixed wiring in accordance with the wiring rules. SL = Switched Live.
To suit Timer Models: BX100WT, BX100CT, BX100+WT, BX100+CT Note: a means for disconnection in all poles must be incorporated in the fixed wiring in accordance with the wiring rules. We recommend a ceiling switch mounted in a suitable position.
To suit Standard Models: BX100W, BX100C, BX100+W, BX100+C
Britex Turbo Shown
Britex LoVolt Fan Unit
FAN & DUCT INSTALLATION INSTRUCTIONS
BriteX LoVolt 1. NOTE: Fan will perform best if ducting is kept as straight as possible (ie. Secure fan to joist, either on top (using a plank if necessary) or on the side but not under any roof insulation. Secure it with the fan blades towards the external grille using two screws through the fixing bracket the arrow on the body shows the direction of airflow. Preferably align the cable with one of the upper spokes in the fan to ensure minimum resistance to airflow. Pass ducting through walls, soffit and/or ceiling as required, fit ducting to grille using tie wraps, then fix grille in place. Pull the flexible ducting gently to the discharge end of the fan and cut and fit ducting to fan casing using tie wraps. Slit duct to clear cable taking care to ensure that duct reinforcing wire does not contact cable. Extend ducting fully and take care to install ducting with minimal changes in direction. For BriteX Turbo fan installation instructions, please refer to the handbook supplied with the fan.
FAN LIGHT UNIT INSTALLATION INSTRUCTIONS
1. [. . . ] Slit the end of the duct to clear the cable, taking care to ensure that the duct reinforcing wire does not damage the cable insulation.
CAUTION: In use, the lamp becomes extremely hot. Replacement dichroic lamps: Sealed 12Vac, 35W maximum, G5. 3 fitting, FMW.
Applied Energy Products Ltd
Morley Way, Peterborough, PE2 9JJ, ENGLAND Telephone: +44(0) 1733 456789 Fax: +44(0)1733 310606 Sales Hotline: +44(0) 8709 000420 http:\\www. xpelair. co. uk
22739AA Revision B [. . . ]