User manual APPLIED ENERGY XPELAIR PREMIER LVCF 20T DC DATASHEET
DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual APPLIED ENERGY XPELAIR PREMIER LVCF 20T DC. We hope that this APPLIED ENERGY XPELAIR PREMIER LVCF 20T DC user guide will be useful to you.
Manual abstract: user guide APPLIED ENERGY XPELAIR PREMIER LVCF 20T DCDATASHEET
Detailed instructions for use are in the User's Guide.
[. . . ] Xpelair Premier LVCF 20T DC
Centrifugal safety extra low voltage fan with UltraDC technology
Key features Type: Selv UltraDC Centrifugal Wall fan with CF. [. . . ] For complete peace of mind Premier LVCF20TDC is IPX5 Safety Extra Low Voltage rated for installation in splash zone 1 and zones 2 / 3 of a bath or shower. Premier features UltraDC offering an 80% reduction in energy use, a choice of installed performances and longer life, typically up to five times longer than a conventional AC motor. For this reason Xpelair offers a full 5 year guarantee.
Application:
Control options:
Legislation:
Hole size:
Select the right product for your application
Premier LVCF 20T DC Reference number Integral pullcord boost override Adjustable overrun timer Quick Visit delayed On Active response humidistat Selectable installed performances Sound pressure level (dB(A)@3m) Electrical power rating IP rating Weight Transformer Guarantee Yes Yes Yes Yes 92288AW 15l/s (30sec-20 minutes) 2 minutes 70-90% RH. Factory set at 70% RH 6l/s 8l/s 13l/s 29. 6 35. 9 34. 5 3. 5W 3. 9W 5. 0W IPX5 4. 25kg Located outside of spray area Zone 3 5 years
15l/s assumes installed with WL kit 34. 8 5. 1W max
Models
Premier LVCF20TDC Ref. 92288AW · UltraDC motor · Selectable installed speeds to satisfy document F1 requirements ( table 1. 1a) - Intermittent bathroom 15l/s - Intermittent sanitary accommodation 8l/s - Continuous extract kitchen 13l/s - Continuous extract bathroom 8 l/s - Continuous extract sanitary accommodation 6l/s · Active response condensation control humidistat factory set for UK ambient conditions. Installer adjustable from 70 - 90%RH · Built-in run-on period after the light has been switched Off, user adjustable from 30s -20min. [. . . ] Applied Energy Products reserve the right to alter product specification or appearance without prior notice. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE APPLIED ENERGY XPELAIR PREMIER LVCF 20T DC
Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual APPLIED ENERGY XPELAIR PREMIER LVCF 20T DC will begin.