User manual BROTHER HL-2400CE
DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual BROTHER HL-2400CE. We hope that this BROTHER HL-2400CE user guide will be useful to you.
You may also download the following manuals related to this product:
BROTHER HL-2400CE Quick Setup (376 ko)
Manual abstract: user guide BROTHER HL-2400CE
Detailed instructions for use are in the User's Guide.
[. . . ] Brother Color Laser Printer
HL-2400Ce series
USER'S GUIDE
Please read this manual thoroughly before using the printer. Keep this manual in a convenient place for quick reference at all times.
I
Trademarks
Brother is a registered trademark of Brother Industries, Ltd. Apple and LaserWriter are registered trademarks, and TrueType is a trademark of Apple Computer, Inc. EPSON is a registered trademark, and FX-850 and FX-80 are trademarks of Seiko Epson Corporation. [. . . ] (Factory setting)
ERROR PRINT=ON ERROR PRINT=OFF
444
CHAPTER 4 CONTROL PANEL
CONTINUE MODE If any recoverable error occurs, including "Toner Empty, " it can be cleared with the Continue button. You need not press the Continue button.
CONTINUE=MANUAL CONTINUE=AUTO
SCALABLE FONT Note The setting in this mode menu is effective only in the HP PCL5C mode. Since this printer has many scalable fonts, some application programs may not be able to handle them correctly. When the HP PCL5C emulation mode has been selected, the printer may print a different font rather than the font you have selected with your program or a font selection command. To cope with this font problem, you can restrict the font selection by using this setting as follows: Display Message Scalable Font All scalable fonts for this printer can be selected with the font selection command. (Factory setting) Scalable fonts for this printer other than the following can be selected with the font selection command: Atlanta, Bermuda Script, PC Brussels, Copenhagen, Germany, Portugal, Calgary, San Diego, and US Roman.
FONT=ALL FONT=LJ
Even if you restrict the font selection as above, you can select among all the scalable fonts with the Font button. The setting in this mode menu merely restricts the font selection command from an application to avoid incorrect font selections.
445
USER'S GUIDE
INPUT BUFFER You can increase or decrease the capacity of the input buffer with the v or w button in this mode menu. A larger capacity allows the printer to receive data from the computer faster. Note If the printer reports a memory full error, reduce the capacity of the input buffer. Display Message ttttttttttttttt tttttttttttttt : : tt t Input Buffer The more squares, the larger the capacity of the input buffer. The squares indicate the capacity but not the size in Mbytes since this depends on the total memory installed in the printer. (Factory setting =ttttt)
After you change the input buffer capacity (make sure you press the Set button), be sure to turn off the printer and then turn it on again. Notes · The set capacity is not changed even if the emulation mode is changed. · The actual capacity of the input buffer varies according to the installed RAM. If the RAM capacity is small, the input buffer capacity may not be increased. Installed memory 1 square 5 squares 15 squares 16M 30KB 0. 9MB 3. 0MB 32M 30KB 4. 3MB 15. 0MB 112M 30KB 21. 4MB 75. 0MB
The Input buffer size increases proportionally .
Fig. 4-7 Input buffer size
446
CHAPTER 4 CONTROL PANEL
SAVE SETTINGS Suppose you share this printer with others who want different control panel settings. Since more than one set of user settings can be stored in the printer's memory, you can easily reset the printer to your preferred settings after they are changed. For resetting the printer, see "RESET Button" in this chapter. Use the control panel to set the configuration of the printer to meet your needs and then enter this mode menu to save your settings. Two sets of user settings can be saved in the printer as follows: Display Message User Setting Save the current settings as No. 2 in the printer's memory.
SAVE SETTING 1 SAVE SETTING 2
If you want to check the user settings, you can print a list of the settings with the Test button. [. . . ] 32 FAULT OUT This signal becomes low when the printer is in the paper empty, off-line, or error states. 36 SLCT IN IN This signal is used only for the bi-directional interface.
12 13 14
PE SLCT AUTO FEED
OUT OUT IN
Appendix9
USER'S GUIDE
Parallel Cable Connection for IBM-PC/AT or Compatible Computers and IBM-PS/2 Computers Signal DATA STROBE DATA 0 DATA 1 DATA 2 DATA 3 DATA 4 DATA 5 DATA 6 DATA 7 ACKNLG BUSY PE SLCT AUTO FEED GND FAULT SLCT IN Printer Pin No. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 18 - 25 15 17
Appendix10
APPENDICES
RS-232C Serial Interface
Standard Specifications 1) Baud rate: 2) 3) 4) 5) 6) 7) 150, 300, 600, 1200, 2400, 4800, 9600, 19200, 38400, 57600 or 115200 baud Synchronization: Start-stop Communications control: No protocol Data length: Serial 7 bits or 8 bits Parity: Odd, even, or none Stop bit: 1 or 2 stop bits Protocol: Xon/Xoff or DTR
Interface Connectors A shielded cable should be used.
13 10 7 4 1
25
21
18
14
Fig. 1 2 3 4 5 6 7 8 9 10 11 12 13 Signal FG SD RD RS NC DR SG NC NC NC NC NC NC IN/OUT Printer Controller Pin No. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE BROTHER HL-2400CE
Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual BROTHER HL-2400CE will begin.