© 2008 Business Objects. patents, which may cover products that are offered and licensed by Business Objects: 5, 555, 403; 5, 857, 205; 6, 289, 352; 6, 247, 008; 6, 490, 593; 6, 578, 027; 6, 831, 668; 6, 768, 986; 6, 772, 409; 6, 882, 998; 7, 139, 766; 7, 299, 419; 7, 194, 465; 7, 222, 130; 7, 181, 440 and 7, 181, 435. Business Objects and the Business Objects logo, BusinessObjects, Business Objects Crystal Vision, Business Process On Demand, BusinessQuery, Crystal Analysis, Crystal Applications, Crystal Decisions, Crystal Enterprise, Crystal Insider, Crystal Reports, Desktop Intelligence, Inxight, the Inxight Logo, LinguistX, Star Tree, Table Lens, ThingFinder, Timewall, Let there be light, Metify, NSite, Rapid Marts, RapidMarts, the Spectrum Design, Web Intelligence, Workmail and Xcelsius are trademarks or registered trademarks in the United States and/or other countries of Business Objects and/or affiliated companies. All other names mentioned herein may be trademarks of their respective owners. [. . . ] ADAPT00881112 Data Integrator was not able to import ATLs that contained object names that were exactly 64 characters in length. The Data Integrator Designer occasionally exited abnormally if an object name (such as table index name) was 64 characters long. ADAPT00882479 When the file reader options adaptable schema and include file name were set and the data file had extra columns defined, Data Integrator did not read all of the rows. ADAPT00883226 Metadata Integrator can now properly work with two tables with the same name but different owners in Data Integrator.
Data Services Release Notes
27
4
Resolved issues
Issue ID
Description
ADAPT00883284 When running a job via the Web Administrator, Data Integrator now handles the global variables correctly. ADAPT00885583 For all CDC table readers, the cache option should always be no. Prior to this release, Data Integrator Designer allowed the user to set the reader option to yes, but did not honor the yes value. This issue has been addressed by not allowing the user to set the reader option to yes. ADAPT00885589 Data Integrator job produced incorrect result when two tables were joined with a user-defined script function in the WHERE clause, and the result data set was part of an outer-join. ADAPT00890818 Data Integrator job execution occasionally ended with the following error: SYS-170111: Cannot stop Memory monitor thread : <RWThreadImp::terminate - No thread is active within the runnable>. ADAPT00892929 Data Integrator job failed with the following error when reading decimal data with scale of 9 or larger while the operating system locale of the Job Server was using the comma character as the decimal separator: cannot convert data<123456. 123456789> into type decimal . ADAPT00896013 The Salesforce. com adapter for Data Integrator now supports the Salesforce. com data type anyType. ADAPT00896020 The Salesforce. com adapter for Data Integrator now correctly queries the field LastModifiedDate on each CDC table, ensuring the data is properly copied. ADAPT00904659 Calling the function <HTTP_ReqReply_Function> no longer returns an error.
28
Data Services Release Notes
Resolved issues
4
Issue ID
Description
ADAPT00905796 Between Data Integrator 11. 7. 1 and 11. 7. 3. 0, when reading CHAR data that contained all spaces from database tables, one space was preserved while all the rest were stripped. This behavior conflicted with the ANSI SQL-92 varchar standard which Data Integrator has complied with since 11. 5. 0 release. This behavior has been corrected in this release to not preserve any spaces. With this release, when ANSI varchar behavior is set and Data Integrator encounters character data of all spaces, the spaces will be trimmed resulting in an empty string. If you want to reserve the space, you can turn off ANSI varchar behavior by setting the ANSI_VARCHAR_BEHAVIOR to FALSE (for more information, refer to varchar behavior section in the MigrationBehaviorChanges document). ADAPT00906629 Comparing a local object with its version stored in the central repository will no longer produce differences. ADAPT00912163 The Configuration tool will now appear after running the cmsCon fig. cmd command. ADAPT00913707 Pushdown SQL functions included in jobs created in Data Integrator version 11. 5 will now work properly when imported in Data Integrator version 11. 7 or later. ADAPT00915902 Data flows were not properly executing when the property cache type was set to pageable. ADAPT00918876 The value field of the al_statistics table now contains no decimal separator, allowing queries on that field to complete successfully. [. . . ] You can correct the problem by cleanly reinstalling the Global Parsing Option. ADAPT00980373 Unable to run EMEA job using al_engine from command line except from the \bin directory. ADAPT00981444 On Windows 64-bit machine, Data Services Install generates an Unknown Error while creating Repository when using a port that is already listening. User is responsible to select unique port for different application (for example, Tomcat, MySQL, and so on. ) when running Data Services on Windows 64-bit environment.
Data Services Release Notes
35
5
Known issues
Issue ID
Description
ADAPT00982063 USA Regulatory Address Cleanse Reports - The percentage values for the LACSLink and DPV counts on the US Addressing Report and Address Validation Summary utilize the total number of records instead of the number of the total records submitted for processing, causing the percentages to be slightly off when Z4 change is enabled or Unicode characters are encountered. [. . . ]