User manual CISSELL CF 446
DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual CISSELL CF 446. We hope that this CISSELL CF 446 user guide will be useful to you.
Manual abstract: user guide CISSELL CF 446
Detailed instructions for use are in the User's Guide.
[. . . ] CISSELL NEITHER ASSUMES, NOR AUTHORIZES ANY PERSON TO ASSUME FOR IT, ANY OTHER WARRANTY OR LIABILITY IN CONNECTION WITH THE MANUFACTURE, USE OR SALE OF ITS EQUIPMENT OR PARTS. For warranty service, contact the Distributor from whom the Cissell equipment or part was purchased. If the Distributor cannot be reached, contact Cissell.
Page 2
TABLE OF CONTENTS
Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ] 3 Steam Piping Recommendations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-5 Operating Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Trouble Shooting Chart . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Parts Sheets . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-13
MR3FC FINISHING CABINET SPECIFICATIONS
Electrical . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 amps, 220V/50 Hz/1 Ph. ; or 8 amps, 115V/60 Hz/1 Ph. Exhaust Duct . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4" diameter with Adjustable damper for variable stack lengths Steam Supply Line . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1/2" NPT Steam Return Line . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1/2" NPT Boiler Horsepower . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60-100 P. S. I. G. Floor Space . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34" deep x 41 1/2" wide x 83" high (86 cm x 105 cm x 211 cm) Net Weight (approximate) . . . . . . . . . . . . . . . . . . . . . . . . . . 560 lbs. (279 kg. ) Export Shipping Dimensions (approximate) 45" x 38" x 86" (114 cm x 97 cm x 218 cm) Export Shipping Weight (approximate) . . . . . . . 615 lbs. (397 kg. ) (wood box) Cubic Feet Export Crating . . . . . . . . . . . . . . . . . . . . . . . . . . 85 cu. ft.
Page 3
STEAM PIPING RECOMMENDATIONS
IMPORTANT: INSTALL STEAM PIPING IN ACCORDANCE WITH ALL LOCAL REGULATIONS AND REQUIREMENTS.
1. First, it introduces moisture to the garment during the steaming cycle (analogous to sprinkling clothes for ironing); second, it allows the moisture to penetrate into the garment during the conditioning cycle (analogous to letting the sprinkled clothes stand overnight); and third, it drys the garment with pressure and heat during the drying cycle by inflating the garment with hot air (analogous to ironing a garment). Because of the variables in the type and weight of garments and steam pressure used, it will be necessary to establish your own cycle time for steaming, conditioning and drying. The shorter the cycle times, the greater will be the number of garments finished in a given time. For convenience, it may be desirable to set the machine for longer cycle times to include all different garments. No more than a week should be required to select your own optimum settings. Steaming Time - For the shortest and surest moisture penetration, the moist steam setting should be selected which allows hot water to be injected along with the dry steam. The amount of water injected is dependent on the setting of the needle valve which is located near the condensate solenoid valve (see manual), usually this will be set at 1/8 to 1/4 turn open. For best results open to the maximum setting that gives a finished garment with no beads of water on the lower hem of garments at the end of the drying cycle. A setting of 15 to 60 seconds for steaming should be suitable for most garments. Conditioning Time - This is a setting which should be increased for heavier garments to allow more time for the moisture to penetrate the fabric of the garment. [. . . ] A setting of 15 to 60 seconds for steaming should be suitable for most garments. Conditioning Time - This is a setting which should be increased for heavier garments to allow more time for the moisture to penetrate the fabric of the garment. On the tunnel models, the moisture penetration can be improved by the steam and air selector which drives the moisture inside the garment and is especially effective on garment linings. Drying Time - This setting will depend on the weight of the garment fabric, type of fabric, length of steaming cycle and length of conditioning cycle. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE CISSELL CF 446
Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual CISSELL CF 446 will begin.