User manual CISSELL CF 47
DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual CISSELL CF 47. We hope that this CISSELL CF 47 user guide will be useful to you.
Manual abstract: user guide CISSELL CF 47
Detailed instructions for use are in the User's Guide.
[. . . ] If you cannot reach your gas supplier, call the fire department.
Installation and service must be performed by a qualified installer, service agency or the gas supplier. WARNING: In the event the user smells gas odor, instructions on what to do must be posted in a prominent location. WARNING: Purchaser must post the following notice in a prominent location:
FOR YOUR SAFETY Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance. WARNING: A clothes dryer produces combustible lint and should be exhausted outside the building. [. . . ] Whenever possible, horizontal runs of steam lines must drain, by gravity, to respective steam header. Water pockets, or an imporperly drained steam header will provide wet steam, causing improper operation of dryer. If pockets or improper drainage cannot be eliminated, install a by-pass trap to drain condensate from the low point in the steam supply header to the return. In both steam supply and steam return line, it is recommended that each have a 3/4" union and 3/4" globe valve. This will enable you to disconnect the steam connections and service the dryer while your plant is in operation. Before connecting trap and check valve to dryer, open globe valve in steam supply line and allow steam to flow through dryer to flush out any dirt and scale from dryer. After flushing system, install bucket trap (with built-in strainer) and check valve. For successful operation of dryer, install trap 18" below coil and as near to the dryer as possible. Inspect trap carefully for inlet and outlet markings and install according to trap manufacturer's instructions. If steam is gravity returned to boiler, omit trap but install check valve in return line near dryer. Install union and globe valve in return line and make final pipe connections to return header.
Page 18
Steam Piping Installation (Illustration)
Page 19
Dryer Installation With Multiple Exhaust For Exhaust Duct less than 14 feet (5 m) and 2 elbows equivalent and less than 0. 3 inches (8 mm) static pressure.
DRYER EXHAUSTS
Area of section A-A must be equal to the sum of dryer exhaust pipes entering multiple exhaust pipe. In summary, there must be the proper size out-of-doors inlet air opening (4-6 times the combined areas of the air outlet) and an exhaust duct, size and length of which allows flow through the dryer with no more than 0. 3 inches water column (. 8 mbar) static pressure in the exhaust duct. In some instances, special fans are required to supply make-up air, and/or boost exhaust fans are required for both regular and energy saving models. Exhaust duct maximum length 14 feet (5 m) of straight duct and maximum of two 90 bends. Use 2 feet (0. 6 m) of straight duct on dryer before installing an elbow on Energy-Saver models only. Use clean-outs in the exhaust duct and clean periodically when needed. Never exceed 0. 3 inches water column (. 8 mbar) static pressure in the exhaust duct. Provide opening to the out-of-doors in accordance with the following: For each dryer 6 inches (2 m) diameter exhaust requires a 1 square feet (0. 1 m) opening for make-up air. 8 inches (3 m) diameter exhaust requires a 2 square feet (0. 2 m)opening for make-up air. 12 inches (4 m) diameter exhaust requires a 4 square feet (0. 4 m)opening for make-up air. Use barometric shutters in the inlet air opening to control air when dryers are not running. OTHER RECOMMENDATIONS TROUBLESHOOTING Other Recommendations To assure compliance, consult local building code requirements. [. . . ] TU15173 TU15157 TU15153 TU15304 TU15612 TU10644 TU15588 TU14414
Description 18 Dia. Sheave (Reversing) 1 1/4 Tappered Bushing 1/4 Key 1 1/4 Cast Iron Bearing Set screw Rotation Bracket Rotation sensor
Ref No. 7 8 9 10 11 12 13 14
Part No.
Description
TU1851 1/2 Flat washer RC347 1/2-13 x 1 1/4 H. H. Screw TU2831 1/2 Lock washer RC349 1/4 Internal tooth washer TU15698 1/4-20 Low head socket bolt TU4787 3/8-16 hex nut TU3243 3/8 Internal tooth washer TU15686 #10-32 x 3/4 lg Set screw (One required for rotation sensor ONLY)
Page 50
MOTOR & FAN ASSEMBLY- NON-REVERSING
Ref. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE CISSELL CF 47
Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual CISSELL CF 47 will begin.