User manual CISSELL DMP

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual CISSELL DMP. We hope that this CISSELL DMP user guide will be useful to you.


CISSELL DMP : Download the complete user guide (308 Ko)

Manual abstract: user guide CISSELL DMP

Detailed instructions for use are in the User's Guide.

[. . . ] If it is necessary to reset the drying and cooling times for the current cycle, press STOP once to stop the dryer. If it is necessary to change programs during a current cycle, press STOP once to stop the dryer and press STOP again to cancel the current cycle Page 2 Diagnostic Microprocessor Control (DMP) 3. 0 DIP Switch Settings The DMP has an 8-position DIP switch bank that is accessible from the back of the control board. By switching these DIP switches, it is possible for the operator to customize the display and some of the operating features of the dryer. Switch # 1 2 3 4 5 6 7 Function Dryer Type Temperature Units Local / Remote Reversing Sail Switch Lint Door Switch Buzzer Timer Safety Tumble (OPL) or Coin Count/Pay (Coin) OPL OFF OFF ON OFF OFF ON ON Coin ON OFF ON OFF OFF ON OFF (OPL=Off; Coin=On) (°F=Off; °C=On) (Local=On; Remote=Off) (Enable=Off; Disable=On) (Enable=Off; Disable=On) (5 Sec=Off; Continuous=On) #1 OFF OFF ON ON 8 Programming OFF OFF #7 ON OFF ON OFF DIPSWITCH SAFETY TUMBLE NO SAFETY TUMBLE COIN COUNT PAY (Disable=Off; Enable=On) Dip Switch Functions Explained #1 Dryer Type: This DIP switch selects the type of dryer, i. e. [. . . ] 5. 4 Toggle between reversing REV (illuminated) or non-reversing REV (not illuminated). 5. 5 To cancel this temporary programming mode push the STOP button once to stop the current cycle and once more to cancel the modified program settings. 6. 0 Reversing Operation 6. 1 When the LOCAL reversing operation is selected, the reversing times are stored in the EEPROM which is located on the controller board. If the values stored are determined to be invalid the clockwise and counterclockwise times will default to 60 seconds, and the dwell time will default to 4 seconds. 6. 2 The reversing time program has the following sequence: (1) clockwise time, (2) dwell time, and (3) counterclockwise time. 6. 4 Press and hold the reverse button (REV) for 3 seconds to display the clockwise time. 6. 5 Use the UP/DOWN arrows to set the clockwise time within the range of 30-120 seconds. 6. 7 Use the UP/DOWN arrows to change the dwell time within the range of 3-10 seconds. 6. 9 Use the UP/DOWN arrows to change the counter-clockwise time within the range of 30-120 seconds. 6. 10 Press the REV button to save these settings and leave DIP Switch #3 in the ON position and flip DIP Switch #8 to the OFF position. When the DMP controller is retrofitted to an existing dryer with the reversing feature, off board reversing will be required and DIP Switch #3 on the DMP must be in the OFF position and the DMP must be connected to the Reversing Timer Board, Cissell part # TU12874 for proper operation. The DMP settings for clockwise, dwell, and counter-clockwise times are no longer valid when used with the Reversing Board. 4. 1 4. 2 4. 3 4. 4 4. 5 4. 6 Page 4 DIAGNOSTIC MICROPROCESSOR CONTROL - FEATURES 7. 0 Rotation Sensor The rotation sensor must read the key on the basket shaft. Look for the light on the sensor to come on as the key passes the sensor; this is a correctly operating sensor. If no light appears either the sensor is out of range of the key or the sensor is bad. In addition, if the light stays on continuously then the se nsor is too close to the shaft or the sensor is bad. 7. 1 Safety Tumble/Anti-Wrinkle At the end of the cooldown cycle, the dryer will stop and display END. The DMP control will automatically rotate the basket for 5 seconds every 2 minutes for a total of 20 minutes, until some function of the dryer is activated/deactivated by the user. 8. 0 Operational Check for the Board Diagnostics 8. 1 dor indicates that the loading door is open. 8. 4 P-F indicates that the thermistor is short circuited or open circuited. 8. 5 Hold the sail switch shut for a few seconds during start up -- Display reads FSS. To clear the display, release the sail switch to normal operation, press STOP then press START. 8. 6 Hold the sail switch open during operation for more than 3 seconds -- Display reads FSS. [. . . ] The drying time is the difference between the run time and the cooling time. Setting DIP switch # 7 to the ON position will display the coin count since it was last reset. Setting DIP switch # 7 to the OFF position will return the display to PAy. 17. 0 Description of Coin Control Panel (See illustration on page 10) 1. Used for programming in the coin mode - increases or decreases the value in the display. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE CISSELL DMP




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual CISSELL DMP will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.