[. . . ] WARRANTY
The Cissell Manufacturing Company (Cissell) warrants all new equipment (and the original parts thereof) to be free from defects in material or workmanship for a period of one (1) year from the date of sale thereof to an original purchaser for use, except as hereinafter provided. With respect to non-durable parts normally requiring replacement in less than one (1) year due to normal wear and tear, including, but not limited to, cloth goods, valve discs, hoses, and iron cords, and with respect to all new repair or replacement parts for Cissell equipment for which the one (1) year warranty period has expired, or for all new repair or replacement parts for equipment other than Cissell equipment, the warranty period is limited to ninety (90) days from date of sale. The warranty period on each new replacement part furnished by Cissell in fulfillment of the warranty on new equipment or parts shall be for the unexpired portion of the original warranty period on the part replaced. With respect to electric motors, coin meters and other accessories furnished with the new equipment, but not manufactured by Cissell, the warranty is limited to that provided by the respective manufacturer. [. . . ] Press Actuator arm onto door switch so that switch is completely depressed. Tighten set screws onto door lever.
ADJUSTMENT OF CONVERTER INTERLOCK
1. Interlock switch should be positioned so that when a flag indicator activates the conveyor interlock switch, a load of garments are completely inside the tunnel. If the adjustment is off, loosen the screws on the conveyor interlock switch bracket and slide bracket until properly positioned.
Page 9
INSTALLATION INSTRUCTIONS
For Connecting Floor Model Link Sections on Conveyor
1. Insert the connecting pin (as illustrated) and replace the E ring in the Groove of the pin. NOTE: Inspect E ring to be certain that it has snapped securely into the groove of the pin.
Page 10
DOOR INTERLOCK SWITCH ADJUSTMENT
1. With doors in closed position the switch should be set as shown in Figure A. Figure B shows correct cam and roller alignment with doors in open position. To check cam and roller alignment press start button and when the doors stop in the open position, turn off main power switch. If the cam has not rotated a full 180º to allow roller to drop into notch, adjust the switch clockwise (up) approximately 1/16. If the cam has rotated more than 180º, adjust the switch counter clockwise (down) approximately 1/16. Repeat until roller drops into notch.
Page 11
INSTALLATION INSTRUCTIONS FOR AF177 MICRO SWITCH PT527 Foot Pedal Complete w/3-Wire Cord 1. Turn switch to inverted position and remove screws (A) as illustrated. Turn power switch on and set timer dials and cycle switches as shown on separate Control Panel Operation page. The group of three links with vertical dividers is a loading station and there are four loading stations. Depress the foot switch or one of the pushbuttons on the top of control console. The doors will open, the load will enter the tunnel, the door close, and the finishing cycle begins. When the first load is finished, machine will stop, then press foot switch or pushbutton again. Doors will open, conveyor will advance, the first load exits onto drop-off, and the second load enters, doors close and cycle begins over. Experimentation with timer dials and switches may be necessary to achieve desired results for different types of fabrics. CAUTION: For proper operation, time must be non-zero on the three timer dials.
Page 15
TROUBLE SHOOTING CHART
Machine will not operate.
PROBLEM
Machine advances to OFF position when started.
Electric power off. Check dip switch settings, 3 & 4 should be on, the rest off.
REMEDY
Machine re-cycles continuously. [. . . ] Elbow Steam Valve 5/16 - 18 x 3/4 Cap Screw 5/16 Flat Washer 5/16 - 18 Hex Nut 1/2 - 20 x 3/4 Cap Screw 1/4 Split Lock 1/4 - 20 Hex Nut 1/4 - 20 x 1/2 Cap Screw #8 x 3/8 Screw 1/4 Compression Tee 3/8 Compression Tee
Page 33
Page 34
STEAM PIPING - 60 HZ
Ref. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 Part No. SC257 SC186 OP297 F646 SC215 SC110 SC158 SC262 SC111 SC60 SC108 SC216 SC168 SC169 SC180 SC253 PT326 SC211 SC219 SC196 OP296 SC220 SF46 SC181 SC214 TU4593 SC183 AT308 OP290 SC164 SC170 SC217 OP449 SC218 SC9 FG160 TU2722 SC182 OP292 OP290 SC16 SC404 OP308 SC185 SC260 C249 VSB130 TU5439 M263 Description Steam Coil Assembly Long Condenser Tube 1/8 Pipe x 1/4 Tube Straight Connection 5/16 Clamp 1/4 Bulkhead Union Rear Boil Off Tube Cross Over Tube Assembly Coil Holdown Bracket Front Boil Off Tube Return Tube Mixing Jet Assembly (See Separate Page) 1/4 M. P. T. Straight Connector Mixing Jet Tube (Water) Mixing Jet Tube (Steam) Steam Tube 3/8 M. P. T. [. . . ]