User manual CISSELL FMMAN58

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual CISSELL FMMAN58. We hope that this CISSELL FMMAN58 user guide will be useful to you.


CISSELL FMMAN58 : Download the complete user guide (763 Ko)

Manual abstract: user guide CISSELL FMMAN58

Detailed instructions for use are in the User's Guide.

[. . . ] FM Form Finisher Models FMCD FMGG FMFC / FMJC / FMLM FMMM MANUAL OWNER'S MANUAL CISSELL MANUFACTURING COMPANY HEADQUARTERS 831 SOUTH FIRST ST. BOX 32270 LOUISVILLE, KY 40232-2270 PHONE: (502) 587-1292 SALES FAX: (502) 585-3625 SERVICE/PARTS FAX: (502) 681-1275 MANUAL THIS MANUAL MUST BE GIVEN TO THE EQUIPMENT OWNER. MAN58 5/96 Page 1 WARRANTY The Cissell Manufacturing Company (Cissell) warrants all new equipment (and the original parts thereof) to be free from defects in material or workmanship for a period of one (1) year from the date of sale thereof to an original purchaser for use, except as hereinafter provided. With respect to non-durable parts normally requiring replacement in less than one (1) year due to normal wear and tear, including, but not limited to, cloth goods, valve discs, hoses, and iron cords, and with respect to all new repair or replacement parts for Cissell equipment for which the one (1) year warranty period has expired, or for all new repair or replacement parts for equipment other than Cissell equipment, the warranty period is limited to ninety (90) days from date of sale. [. . . ] Wipe dust and lint off of surfaces A, A1, B, B1, C and D. FIRST: SECOND: THIRD: FOURTH: Spread DOW CORNING "VALVE SEAL A" (Heat Stable Silicon Lubricant) with a piece of cardboard over surface A, and apply to bearing points C and D. With Finger, pack inside of dome above ball bearing B1 with Valve Seal A. METALLIC TO REPLACE METALLIC STEAM SPREADER FIRST: Remove old metallic spreader if it fails to diffuse steam properly. Fold new copper mesh "L" over, three times, into approximately a 1 1/2" width band, 18" long. Wrap copper mesh tightly around valve body. SECOND: THIRD: Place perforated brass draw band with ring "M" around copper mesh. Fold band back over ring with a pair of pliers to keep band tight. FOURTH: LUBRICATING INSTRUCTIONS FOR LUBRICATING BEARING POINTS ON OUTSIDE OF BASE Wipe bearing surfaces clean and oil with a lightweight oil, at least every 60 days. NOTE: Nylon bearings do not require lubrication. Page 16 CISSELL STEAM-AIR FINISHER INSTRUCTIONS FOR ADJUSTING HEIGHT REVOLVING OF REVOLVING FORM (Model FM** and Model FG-1) Should the revolving form "drag" on the base rather than turn freely, the form must be raised. Conversely, if the revolving form hides too high above the base, permitting steam to escape from the space between the form and base, the form must be lowered. WHEN AN ADJUSTMENT MUST BE MADE, REMOVE REVOLVING FORM BY SIMPLY LIFTING IT STRAIGHT UP OFF THE BASE. Turn F287 Bearing Adjustment Screw COUNTER-CLOCKWISE. CHECK ADJUSTMENT: Replace revolving form on base. If perfectly adjusted, form will rotate freely and snugly on felt seal around top of base. If form is still too low. . . or too high. . . repeat adjustment until it is correct. Turn F287 Bearing Adjustment Screw CLOCKWISE. CHECK ADJUSTMENT: Replace revolving form on base. If perfectly adjusted, form will rotate freely and snugly on felt seal around top of base. If form is still too high. . . or too low. . . repeat adjustment until it is correct. Page 17 AIR DAMPER LINKAGE ADJUSTMENT 1. Check to see that the pins in the air solenoid lever and air damper lever are located as shown below. Loosen the set screw in the air damper lever hub and, with the damper closed, rotate the lever until the air solenoid armature gap is 7/8". Check to see that there is slight end play of the levers on the air damper shaft so they may rotate freely. NOTE: If the damper does not open in a positive manner, reconnect the lower end of the damper opening spring to the alternative connection position shown below. AIR PRESSURE SETTING ADJUSTMENT 1. Move the air pressure control lever on top of the control enclosure to minimum setting. With the blower motor running and the air damper closed, move the air pressure lever until it touches the pin in the lower end of the air damper lever. Tighten the damper wire set screw onto the damper wire tightly. Page 18 ALVE STEAM VALVE LINKAGE ADJUSTMENT 1. [. . . ] Check to see if relay will operate on rated voltage and if contacts will carry current. See that timer motor will run and that timer switch operates properly. Replace if it is burned, armature does not move freely, or if it will not operate on rated voltage. Pins on these levers must be properly arranged with respect to adjoining levers. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE CISSELL FMMAN58




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual CISSELL FMMAN58 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.