User manual CISSELL MAN65

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual CISSELL MAN65. We hope that this CISSELL MAN65 user guide will be useful to you.


CISSELL MAN65 : Download the complete user guide (199 Ko)

Manual abstract: user guide CISSELL MAN65

Detailed instructions for use are in the User's Guide.

[. . . ] No defective equipment or part may be returned to Cissell for repair or replacement without prior written authorization from Cissell. Charges for unauthorized repairs will not be accepted or paid by Cissell. CISSELL MAKES NO OTHER EXPRESS OR IMPLIED WARRANTY, STATUTORY OR OTHERWISE, CONCERNING THE EQUIPMENT OR PARTS INCLUDING, WITHOUT LIMITATION, A WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE, OR A WARRANTY OF MERCHANTABILITY. [. . . ] Whenever possible, horizontal runs or steam lines must drain, by gravity, to respective steam header. Water pockets, or an improperly drained steam header will provide wet steam causing improper operation of Cabinet. If pockets or improper drainage cannot be eliminated, install a by-pass trap to drain condensate from the low point in the steam supply header to the return. In both the steam supply and steam return line, it is recommended that each have a 1/2" union and 1/2" globe valve. This will enable you to disconnect the steam connections and service the Cabinet while your plant is in operation. Before connecting trap and check valve to Cabinet, open globe valve in steam supply line and allow steam to flow through Cabinet to flush out any dirt and scale from Cabinet. If steam is dirty, it will be adviseable to install a filter or blow down line ahead of cabinet. Inspect trap and strainer carefully for inlet and outlet markings and install according to manufacturers instructions. If steam is gravity returned to boiler, omit trap but install check valve in return line near Cabinet. When cabinet is on end of a line of equipment extend headers at least 4 ft. Insulate steam supply and return lines for safety of operator while servicing Cabinet. The interior of the tunnel will turn white as the protective zinc oxide coating forms. Do remove lint, dust, and boiler compound or red dust which is entrained by the steam. Page 4 Page 5 OPERATING INSTRUCTIONS FOR CISSELL MOIST-RITE CABINETS AND TUNNELS Forward - The Moist-Rite Finishing Cabinets and Finishing Tunnels are designed to restore the finish on most garments. [. . . ] Remember - a good finish job starts with enough moisture, if in doubt, increase the steaming time and/or the needle valve setting. Page 6 PROBLEM Machine will not operate CAUSE Electric power off Loose or broken wires to start button Defective start switch Defective timer cam or drive Advance button is defective or depressed Defective wiring Start button stuck or defective Defective wiring Defective timer Defective wiring or short circuit Potentiometer knob incorrectly set Loose or broken wires Defective timer Water metering valve turned off Water solenoid valve defective Water solenoid valve not electrically energized Defective timer Water line clogged Steam line clogged Steam solenoid valve defective Steam solenoid valve not electrically energized Defective timer Moisture metering valve open too wide Steam trap not functioning properly Condensate line strainer clogged Motor defective Timer defective Relay defective Wiring defective Blower wheel loose Defective blower wheel Foreign object in blower wheel Exhaust damper closed Blower not operating Exhaust duct clogged Steam cycle too long REMEDY Turn power on. Connector Mixing Jet Tube (Water) Mixing Jet Tube (Steam) 1/4 Pipe x 3/8 Tube St. Connector Rear Boil Off Tube Return Tube Steam Coil Assembly w/deflectors Front Boil Off Tube 3/8" Angle Connector 3/8" Greenfield Cable 3/8" Straight Connector Junction Box Cover Junction Box Bushing 3/4 Lock Nut 3/4" Conduit 3/8 x 3/8 Elbow Solenoid Steam Valve 120V Strainer Nipple Assembly Mounting Bracket 1/2" All Thread Nipple 1/2 x 5 Pipe Nipple 1/2 x 1/4 Reducer 1/8 Pipe x 1/4 Tube Elbow 3/8 Connector w/Set Screw 1/2x3/8x1/2Tee Junction Box Cover Steam Tube Steam Supply Tube 1/4 Bulkhead Union 3/8 Bulkhead Union Short Return Tube Water Tube 1/8 Pipe x 1/4 Tube Elbow 1/8" Metering Valv Solenoid Valve (Condensate) Strainer Assembly Pipe Plug Air Deflector for Steam Coil Air Deflector for Steam Coil 3/8 Compression Bead 3/8 Compression Nut Elbow, 3/8 Pipe x 1/2 Flare Tube Condenser Water Tube Condenser Assembly Condenser Mounting Bracket Page 11 CONTROL PANEL ASSEMBLY SC876 - Control Panel - 120 V. , 60 Hz. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE CISSELL MAN65




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual CISSELL MAN65 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.