User manual CISSELL MANHD50.1
DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual CISSELL MANHD50.1. We hope that this CISSELL MANHD50.1 user guide will be useful to you.
Manual abstract: user guide CISSELL MANHD50.1
Detailed instructions for use are in the User's Guide.
[. . . ] HD LAUNDRY DRYER Gas: Natural and LP Steam Electric
Technical specifications Installation instructions Operating instructions Maintenance
HD50. 1
MANHD50. 1
Cissell Manufacturing Co.
831 S. - 40232-2270 Tel: (502) 587-1292 - Fax: (502) 585-2333 Sales Fax: (502) 585-3625 - Service/Parts Fax: (502) 681-1275
THIS MANUAL MUST BE GIVEN TO THE EQUIPMENT OWNER 7/02
IMPORTANT NOTICESPLEASE READ
For optimum efficiency and safety, we recommend that you read the manual before operating the equipment. WARNING: Purchaser must post the following notice in a prominent location:
WARNING: For your safety, the information in this manual must be followed to minimize the risk of fire or explosion or to prevent property damage, personal injury or death.
- Do not store or use gasoline or other flammable vapors or liquids in the vicinity of this or any other appliance. Do not touch any electrical switch; do not use any phone in your building. [. . . ] of Dryers Duct Diameter (in inches) (in CM)
HD50 123
4
5
6
7
8
9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
8 12 14 16 18 20 22 23 24 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 20 30 25 41 46 51 56 58 61 66 68 71 73 76 78 81 84 86 89 91 94 97 99 100
Exhaust Booster Fan Power Supply to Fan ____ ____ ____ ____ ____ ____
Relay Coils Start and Stop Switches on Dryers
Page 20
Dryer Installation with Multiple Exhaust
DRYER INSTALLATION WITH MULTIPLE EXHAUST
For Exhaust Duct more than 14 feet (5 m) and 2 elbows equivalent and more than 0. 3 inches (8 mm) static pressure. Make-up air from outside building may enter enclosure from top or side walls. (See Dryer Make-Up Air Chart) Use constant diameter duct with area equal to the sum of dryer duct areas. EXAMPLE: Six 8 inch (204 mm)) diameter duct = one 19. 6 inch (498 mm) diameter duct in area. Use 20 inch (508 mm) diameter duct or diameter to match tube-axial fan. If dryers use room air instead of outside air, the heat loss can be another 25 Btu/h (6. 3 kcal/h) for each cubic foot per minute (cfm) used. Zero inches clearance to combustible material allowed on sides and at points within 4 inches (102 mm) of front on top. Heat loss into laundry room from dryer fronts only is about 60 Btu/h per square foot (15 kcal/h per 0. 1m²). See suggested Automatic Electrical Control Wiring Diagram on previous page. Fan air flow (cfm) (m³/min. ) is equal to sum of dryer air flows, but static pressure (SP) is dependent on length of pipe and number of elbows. Barometric bypass damperadjust to closed flutter position with all dryers and exhaust fan running. 6.
7.
CAUTION: Never install hot water heaters or other gas appliances in the same room as dryers. CAUTION: Never exhaust dryers with other types of equipment.
Page 21
Suggested Minimum Dryer Make-up Air Requirements Dryer Model C 30 ST C 75 ST C 110 C 110 E/S C 125 C 150 HD175 HD190 HD20. 1 HD30SL HD30. 1 HD50. 1 HD75. 1 HD80. 1 Dryer Pocket Capacity lb kg 30 13. 6 75 34 110 50 110 50 125 56. 7 150 68 175 79. 4 190 86. 2 20 9. 1 30 13. 6 30 13. 6 50 22. 7 75 34 80 36. 3 Maximum Air Flow Duct Size For Required Make-up Rate per Pocket Service Connection Air Area per Pocket cfm m3/h inch mm sq. inch cm2 450 765 6 153 87 561 1000 1700 12 305 192 1240 2200 3740 12 305 422 2723 850 1445 8 203 163 1052 2000 3400 12 305 384 2477 2250 3825 12 305 432 2787 2780 4726 12 305 534 3445 3000 5100 12 305 576 3716 450 765 6 153 87 561 600 1020 8 203 116 748 625 1063 8 203 120 774 850 1445 8 203 164 1058 1000 1700 8 203 192 1240 1000 1700 10 254 192 1240
Notes: 1) The Model C 30 ST has 2 pockets per dryer, each pocket has the above listed characteristics; each pocket is exhausted separately with a 6" (153mm) duct. 2) The Model C 75 ST has 2 pockets per dryer, each pocket has the above listed characteristics; both pockets have one 8" (203mm) exhaust manifolded into one 12" (305mm) exhaust duct for exhaust connection. 3) For the C 30 ST and the C 75 ST Models, the Required Make-up Air Area shown in the table should be doubled since it is shown per pocket, only.
Page 22
Dryer Installation With Separate Exhaust (Preferred)
DRYER INSTALLATION WITH SEPARATE EXHAUST (PREFERRED)
For ductwork less than 14 feet (5 m) and 2 elbows equivalent and less than 0. 3 inches (8 mm) static pressure: NEVER exhaust the dryer into a chimney. Make-up air opening from outside the building may enter the enclosure from the top or side walls. If dryers use room air instead of outside air, additional heat loss can be another 25 Btu/h (6. 3 kcal/h) for each cubic foot per minute (cfm) (. 03m³/min. ) used. The installation clearance from all combustible material is 0" ceiling clearance for the first 4" (102 mm) from the front of the dryer. After the first 4" (102 mm), the ceiling clearance required is 6" (153 mm). The rear clearance required is 0", and the side clearance is 1" (26 mm). Heat loss into laundry room from dryer front panels is about 60 Btu/h per square foot (15 kcal/h per 0. 1m²).
3.
4.
Page 23
Exhaust and Venting
DRYER AIR FLOW INSTALLATION Nothing is more important than air flow for the proper operation of a clothes dryer. [. . . ] Sheave cast IR 2. 0X1/2 60hz 13 Fan 50hz 12 Fan 60hz Nut, 1/2-20 left hand rev. (2 each) Motor mount Gasket, curved (2 each) Gasket, cork 8 (2 each) Washer, lock 5/16 (4 each) Screw, cap HH 5/16-18 (4 each) Washer, cut 5/16 (4 each)
Page 51
PARTSSMALL GEAR REDUCERTM100
Quantity 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 TM103 TM104 TM105 TM107 TM108 TM101 TM110 TM112 TM115 TM117 TM102 TM120 TU2623 TU2839 TU3243 RC349 TM118 TU4787 TU3211 TM119 Housing Small Seal Small Open End Cap Small Bearing Cup Small Bearing Cone Worm 1-1/2 x 7-1/8 Large Bearing Cup Large End Cap 1/4 Pipe Plug Large Bearing Cone Worm Gear Oil Seal Cap Screw 3/8 - 16 x 1-1/2 Cap Screw 1/4 - 20 x 7/8 3/8 Internal Tooth Lockwasher 1/4 Internal Tooth Lockwasher Small Closed End Cap 3/8 - 16 Hex Nut 3/8 - 16 x 2-1/2 Screw Vent Plug 1/4 NPT 1 1 1 2 2 1 2 1 1 2 1 2 4 8 6 8 1 2 2 1
Page 52
MOTOR & GEAR REDUCER ASSEMBLY
Ref. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
Part No. TU2317 510101041 TU6722 TU5241 TM100 TU1851 TU2831 RC347 TU15517 MTR303 TU33 IB140 TU4787 TU14414 VSB134 TU3246 TU4934 TU2846 TU2847 RC344 TU4684 TU8608 TU15516 510101040 TU7334 TU2833
Description BELT, V 4L-380 SHEAVE, AK39 (50 Cycle) SHEAVE, AK-51H (60 Cycle) KEY, 3/16 SQ. [. . . ]