User manual CISSELL MANHD75ST

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual CISSELL MANHD75ST. We hope that this CISSELL MANHD75ST user guide will be useful to you.


CISSELL MANHD75ST : Download the complete user guide (816 Ko)

Manual abstract: user guide CISSELL MANHD75ST

Detailed instructions for use are in the User's Guide.

[. . . ] HD STACK LAUNDRY DRYER Gas: Natural and LP Steam HD75ST Cissell Manufacturing Co. 831 S. - 40232-2270 Tel: (502) 587-1292 - Fax: (502) 585-2333 Sales Fax: (502) 585-3625 - Service/Parts Fax: (502) 681-1275 THIS MANUAL MUST BE GIVEN TO THE EQUIPMENT OWNER Page 1 MANHD75ST 05/02 IMPORTANT NOTICES--PLEASE READ For optimum efficiency and safety, we recommend that you read the manual before operating the equipment. WARNING: For your safety, the information in this manual must be followed to minimize the risk of fire or explosion or to prevent property damage, personal injury or loss of life. - Do not store or use gasoline or other flammable vapors or liquids in the vicinity of this or any other appliance. [. . . ] Use 21 inch (534 mm) diameter duct or diameter to match tube-axial fan. Zero inches clearance to combustible material allowed on sides and at points within 4 inches (102 mm) of front on top. Heat loss into laundry room from dryer fronts only is about 60 Btu/hr per square foot. See suggested Automatic Electrical Control Wiring Diagram on previous page. Fan air flow (cfm) is equal to sum of dryer air flows, but static pressure (SP) is dependent on length of pipe and number of elbows. Barometric Bypass Damper--Adjust to closed flutter position with all dryers and exhaust fan running. Must be located within enclosure. CAUTION: Never install hot water heaters or other gas appliances in the same room as dryers. Never install cooling exhaust fans in the same room as dryers. Page 19 Exhaust Installation--Multiple Manifold Duct (Illustration) Page 20 Suggested Minimum Dryer Make-up Air Requirements Dryer Model C 30 ST C 75 ST C 110 C 110 E/S C 125 C 150 HD175 HD190 HD20. 1 HD30SL HD30. 1 HD50. 1 HD75. 1 HD80. 1 Dryer Pocket Capacity lb kg 30 13. 6 75 34 110 50 110 50 125 56. 7 150 68 175 79. 4 190 86. 2 20 9. 1 30 13. 6 30 13. 6 50 22. 7 75 34 80 36. 3 Maximum Air Flow Duct Size For Required Make-up Rate per Pocket Service Connection Air Area per Pocket cfm m3/h inch mm sq. inch cm2 450 765 6 153 87 561 1000 1700 12 305 192 1240 2200 3740 12 305 422 2723 850 1445 8 203 163 1052 2000 3400 12 305 384 2477 2250 3825 12 305 432 2787 2780 4726 12 305 534 3445 3000 5100 12 305 576 3716 450 765 6 153 87 561 600 1020 8 203 116 748 625 1063 8 203 120 774 850 1445 8 203 164 1058 1000 1700 8 203 192 1240 1000 1700 10 254 192 1240 Notes: 1) The Model C 30 ST has 2 pockets per dryer, each pocket has the above listed characteristics; each pocket is exhausted separately with a 6" (153mm) duct. 2) The Model C 75 ST has 2 pockets per dryer, each pocket has the above listed characteristics; both pockets have one 8" (203mm) exhaust manifolded into one 12" (305mm) exhaust duct for exhaust connection. 3) For the C 30 ST and the C 75 ST Models, the Required Make-up Air Area shown in the table should be doubled since it is shown per pocket, only. Page 21 Exhaust Installation--Separate Ducts (preferred) EXHAUST INSTALLATION-- SEPARATE DUCTS (PREFERRED) For ductwork less than 14 feet (5 m) and 2 elbows equivalent and less than 0. 3 inches (8 mm) static pressure. Make-UpAiropeningfromoutsidethebuildingmayenterthe enclosure from the top or side walls. Zero inches clearance to combustible material allowed on sides and at points within 4 inches (102 mm) of front on top. Heat loss into laundry room from dryer front panels is about 60 Btu/hr per square foot. As shown below, separate 12" (305 mm) ducts are recommended for each 75 lb. (35 kg) Stack Dryer. Page 22 Exhaust and Venting DRYER AIR FLOW INSTALLATION Nothing is more important than air flow for the proper operation of a clothes dryer. A dryer is a pump which draws make-up air from the out-of-doors, through the heater, through the clothes and then forces the air through the exhaust duct back to the out-of-doors. Just as in a fluid water pump, there must be a fluid air flow to the inlet of the dryer, if there is to be the proper fluid air flow out of the exhaust duct. In summary, there must be the proper size out-of-doors inlet air opening (4-6 times the combined areas of the air outlet) and an exhaust duct, size and length of which allows flow through the dryer with no more than 0. 3 inches water column static pressure (8. 8 mbar) in the exhaust duct. In some instances, special fans are required to supply make-up air, and/or boost exhaust fans. Exhaust duct maximum length 14 feet (5 m) of straight duct and maximum of two 90° bends. Use clean-outs in the exhaust duct and clean periodically when needed. [. . . ] 6) #8-32 Hex Nut Basket Door Seal Delrin Bearing Basket Door Handle Basket Door Rubber Gasket Door Glass #10-32 x 3/8" Taptite Scr. Door Catch Assembly with Rivets #10 Lock Washer Front Panel Access Door #8 x 1/2" Self Drill Screw Page 44 Front Panel Assembly - Reed Switch - OPL TUT452 - COMPLETE ASSEMBLY W/ FRICTION CATCH TUT458 - COMPLETE ASSEMBLY W/ DOOR LATCH 1 2 3 4 5 6 7 8 9 10 11 12 13 EA-00652-0 EA-00827-0 PIF172 TUA2319H* TUT304C TUT451WHT TU14467* TU2236 TU2686* TU2687* TU2836 TU2874 TU2876 SWITCH, REED MTG PLATE, REED SWT. LATCH COVER PLATE FRONT PANEL - OPL BSKT DR, OPTIONAL HINGE, CAST POST #8-32 PAN HD SCR #8 PH HD SCR. SCREW, HEX HD 5/16-18 HANDLE LATCH, DELRIN FRICTION 14 15 16 17 18 19 20 21 22 23 24 25 TU3163 TU3213 TU3215 TU3209 TU5288 TU3785* TU4840 TU5503* TU5859 TU7169 TU7733 TU7862 PIN, CATCH RIVET 10-32 SCREW SCREW, SHT. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE CISSELL MANHD75ST




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual CISSELL MANHD75ST will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.