User manual CISSELL PANTOPBEXCMAN309X
DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual CISSELL PANTOPBEXCMAN309X. We hope that this CISSELL PANTOPBEXCMAN309X user guide will be useful to you.
Manual abstract: user guide CISSELL PANTOPBEXCMAN309X
Detailed instructions for use are in the User's Guide.
[. . . ] - WHAT TO DO IF YOU SMELL GAS · · · · · Do not try to light any appliance. Do not touch any electrical switch; do not use any phone in your building. If you cannot reach your gas supplier, call the fire department.
Installation and service must be performed by a qualified installer, service agency or the gas supplier.
WARNING: In the event the user smells gas odor, instructions on what to do must be posted in a prominent location. WARNING: Purchaser must post the following notice in a prominent location: FOR YOUR SAFETY Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance. [. . . ] CAUTION: Low gas pressure and intermittent gas will cause gas ignition problems. The dryer and its individual shut-off valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of 1/2 psig (. 04 bar). The dryer must be isolated from the gas supply piping system by closing its individual manual shut-off valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 psig (. 04 bar).
LP GAS ONLY
Page 16
Gas Service Installation Information GENERAL INSTALLATION FOR ALL DRYERS The size of the gas service pipe is dependant upon many variables, such as tees, lengths, etc. Refer to the Gas Pipe Size Chart in this manual for general gas pipe size information. CAUTION: Gas loop piping must be installed as illustrated to maintain equal gas pressure for all dryers connected to a single gas service. Other gas-using appliances should be connected upstream from the loop.
WARNING: LIQUIFIED PETROLEUM GASES ONLY A Gas Pressure Regulator for Liquified Petroleum Gases is not furnished on the gas heated clothes dryers. In accordance with American Gas Association (AGA) standards, a Gas Pressure Regulator, when installed indoors, must be equipped with a vent limiter or a vent line must be installed from the Gas Pressure Regulator vent to the outdoors.
Page 17
Exhaust Installation--Multiple Manifold Duct For Exhaust Duct less than 14 feet (5 m) and 2 elbows equivalent and less than 0. 3 inches (8 mm) static pressure.
v
A
A
A
Air Flow to Outside Building
v
)30°- 45°
A A A
DRYER EXHAUSTS Area of section "A-A" must be equal to the sum of dryer exhaust pipes entering multiple exhaust pipe. of Dryers Duct Diameter (in inches)
1 2 3 4 5 6 7 8 9 10 11 12 12 17 21 24 27 30 32 34 36 38 40 42
UTOMA OMATIC CONTROL EXHAUST FAN AUTOMATIC ELECTRICAL CONTROL FOR EXHAUST FAN For one or more dryers to start fan. Exhaust Booster Fan Power Supply to Fan ____ ____ ____ ____ ____ ____
Relay Coils
(relays furnished by customers)
Start and Stop Switches on Dryers
Page 18
Exhaust Installation--Multiple Manifold Duct EXHAUST INSTALLATION-- MULTIPLE MANIFOLD DUCT For Exhaust Duct more than 14 feet (5 m) and 2 elbows equivalent and more than 0. 3 inches ( 8 mm) static pressure. Make-up air from outside building may enter enclosure from top or side walls. Use constant diameter duct with area equal to the sum of dryer duct areas. Use clean-outs in the exhaust duct and clean periodically when needed. Never exceed 0. 3 inches water column static pressure (8. 8 mbar) in the exhaust duct. MAKE-UP AIR Provide opening to the out-of-doors in accordance with the following: Each 75 lb. Use barometric shutters in the inlet air opening to control air when dryers are not running. Other Recommendations To assure compliance, consult local building code requirements. Troubleshooting Hot dryer surfaces, scorched clothes, slow drying, lint accumulations, or air switch malfunction are indicators of exhaust duct and/or make-up air problems.
Page 23
Rules for Safe Operation of Dryer
RULES FOR SAFE OPERATION OF DRYER 1. Be sure your dryer is installed properly in accordance with the recommended instructions. CAUTION Be safe--shut main electrical power supply and gas supply off externally before attempting service. CAUTION Never use drycleaning solvents: gasoline, kerosene, or other flammable liquids in the dryer. Never use heat to dry items that contain plastic, foam or sponge rubber, or rags coated with oils, waxes or paints. Serious injury will occur if a child should crawl inside and the dryer is turned on. [. . . ] 6) #8 Speed Clip (2 each)
Page 42
Thermostat Assembly - ESA-00961-0
Ref. CA-13172 EA-00411-0 SB-00828 SB-00952 TU11991 TU3266 TU3400
Description MTG. Bracket Switch - 220 Degree #8-32 x 1/2 Screw #6-32 x 3/8 Screw Thermistor #8-32 Hex Nut #6-32 Hex Nut
Page 43
Illustration (Front Panel and Door Assembly)- OPL
TUT272 - COMPLETE ASSEMBLY 1. TUT149D TU2194 TU2105 M262 FB187 TU3266 TU5288 PIF172 TU2874 TU5859 TU7169 TU7862 TU3215 TU3163 Front Panel Weld Assembly Door Switch Actuator Actuator Spring #8-32 TR. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE CISSELL PANTOPBEXCMAN309X
Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual CISSELL PANTOPBEXCMAN309X will begin.