User manual CONTAX CC 2000 DATASHEET
DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual CONTAX CC 2000. We hope that this CONTAX CC 2000 user guide will be useful to you.
Manual abstract: user guide CONTAX CC 2000DATASHEET
Detailed instructions for use are in the User's Guide.
[. . . ] CC 2000 Controller
w w w w w w w
Kyocera Solar Water Pumping Systems and Components are Manufactured by Kyocera Solar, Inc.
Accommodates Arrays with two to twelve 36-cell Modules in Series; Will Operate from 24 to 144 volt Battery Banks Maximum Power Point Tracking Self Programming Operation Current Boosting Self Diagnostic Simplified Control and Troubleshooting LED Indicators Provide Convenient Information about Voltages, Switch and Sensor Status and Overload Conditions
The CC 2000 pump controller is designed to connect solar modules to Kyocera Solar's SC series submersible motors and centrifugal pumps. [. . . ] Any combination of modules can be used as long as the total Open Circuit Voltage (VOC) does not exceed 300 Volts. Strings of modules can be wired in parallel to maximize daily water production. In addition to solar modules, the controller will also operate from 24 to 144 Volt battery banks for use in a broad range of applications. The CC 2000 controller is only intended for use with Kyocera Solar's SC series of motors. The controller's unique design simplifies control and troubleshooting of pumping systems. Inputs are provided for remote switches and Kyocera Solar's unique water level sensor. [. . . ] We are proud to introduce the Kyocera Solar line of pump controllers and are confident you will be satisfied.
CC 2000 Controller Display
CC2000 Controller Specifications
Description Maximum Ambient Temperature Minimum Ambient Temperature Maximum Solar/Input Voltage (total VOC @ -20°C) Maximum Output Current - Current Boost Mode (input voltage greater than output voltage) Maximum Output Power - Current Boost Mode (input voltage greater than output voltage) Input Current Limiting High Temperature Protection (shutdown temperature at heatsink) Solar and Pump Wire Sizes Sensor and Remote Switch Wire Sizes 50° C -20° C 300 Volts 14 Amps 2000 Watts 15 Amps 85° C 0. 5 - 16 mm2 6 - 20 AWG 0. 2 - 2. 5 mm2 14 - 24 AWG
7812 East Acoma Drive Scottsdale, AZ 85260 USA 480. 951. 6330 FAX: 480. 951. 6329 800. 544. 6466 www. kyocerasolar. com [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE CONTAX CC 2000
Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual CONTAX CC 2000 will begin.