User manual CONTAX GSM REV A

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual CONTAX GSM. We hope that this CONTAX GSM user guide will be useful to you.


CONTAX GSM REV A: Download the complete user guide (401 Ko)

Manual abstract: user guide CONTAX GSMREV A

Detailed instructions for use are in the User's Guide.

[. . . ] Generator Start Module GSM Installation and Operation Guide ã2001 Xantrex Technology Inc. P/N 975-0008-01-02 Rev. A 01/01 GSMGenerator Start Module Table of Contents 1. 0 INTRODUCTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Unpacking and Inspection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Controls and Indicators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ] This is a safety feature which allows the generator to be serviced without it unexpectedly starting due to an inverter GEN-START command. GENERATOR START Switch The GENERATOR START switch enables the relays by providing the operating voltage to the relay coils RY7 and RY8. When the relays are enabled, they will respond to the control signals provided by the inverter. When the switch is in the RELAYS DISABLED position, the inverter control signals have no effect on relay operation (i. e. , the COM and N. C. This switch does not affect the operation of the LEDs which continue to light whenever the inverter sends a CLOSE CONTACT command to the relays. INVERTER ERROR Switch The INVERTER ERROR switch provides a simple way to test an externally connected alarm. Once the alarm is tested, this switch should be switched to the RELAY READY position. GENERATOR Switch (RY7 and RY8) INVERTER ERROR Switch (RY 11) Figure 3 Switches ©2001 Xantrex Technology Inc. 3 1. 0 INTRODUCTION Internal Components The Generator Start Module (GSM) is designed to control generators equipped with two- or three-wire, electronic, automatic start operation (not all generators are supported) and provides the following features. Relays There are three 12 VDC relays, rated at 10 amps/250 VAC; 8 amps/ 30 VDC (for resistive loads), with gold contacts increasing the low-end signal range. Relay RY11 can be connected to an external indicator device to display or sound an alarm whenever the inverter AC output is lost. The normally open (N. O. ) and normally closed (N. C. ) contacts are available to accommodate the various generator auto-start circuits. Relay Terminal Block Connections to the GSM are accomplished by the nine position, spring clamp, terminal block with quick connect levers. All relay contacts (N. O. , COM and N. C. ) are available at this connector, which accepts wire sizes from #28 AWG to #14 AWG. No tools are required to secure the wires as the spring clamp holds the wires securely in place. Ground Stud A ground screw is provided in the GSM to provide a safety ground path when hazardous voltages are connected to the relays. Connect this screw to a grounded conductor whenever high voltages (i. e. , above 90 volts) are connected to the relays. NOTE: No hazardous voltages are supplied from the inverter to power or control the relays; however, some generator control circuits may use a high voltage in their starting/control circuits or 120 V could be used for an external error indicator. Fuses Each relays common (COM) contact is protected with a 6. 3 amp (5 mm x 20 mm) 250 VAC fuse which will open if excess current is drawn through the relay contacts. NOTE: These fuses can be replaced with lower amperage fuses to also protect the connected circuitry, if desired. To connect the generator wires to the terminal block Lift the appropriate lever for the relay contact. Please refer to the generator section of the inverters operation manual for additional information. NOTE: Due to the various wiring schemes used by different manufacturers, detailed wiring instructions can not be given in this manual. Please refer to the generator manufacturers documentation for wiring details. [. . . ] (DO NOT EXCEED RELAY CONTACT RATING) LED1 RELAY RY7 SW1 RELAY RY8 SW1 RELAY RY11 SW2 NO C Terminal Block wire size: 14-28 AWG Wire strip length: . 25" (6mm) Interconnect cable (J1): Connect to Gen Port of Trace Inverter WARNING: DO NOT OPERATE WITH COVER REMOVED. HAZARDOUS VOLTAGES MAY BE PRESENT. NC NO C NC NO C NC Figure 14 Internal Component Identification Sticker Danger Label A danger label is included with the GSM to warn service personnel that the generator may suddenly start without warning (due to an inverter command). Place this label close to the generator where it can easily be seen. GENERATOR HAS AN AUTO START SYSTEM WHICH MAY CAUSE THE GENERATOR TO START WITHOUT WARNING DISABLE GENERATOR AUTO START BEFORE SERVICING 270-0025-01-01 PN 110-0035 - J1 SW 1 LED2 F1 F2 F3 R4D1 R3 R2 R1 LED3 SW 2 TB1 1 9 PN: 270-0023-01-02 GENERATOR AUTO START SYSTEM Figure 15 Danger Label 16 ©2001 Xantrex Technology Inc. 4. 0 TROUBLESHOOTING Troubleshooting The GSM contains no serviceable parts other than the three fuses in the common contact circuit of the relays. If the module requires servicing, return it to Xantrex Technology Inc. , or contact a Xantrex representative for assistance. Symptom Blue LED does not light. Possible Cause Inverter not turned ON. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE CONTAX GSM




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual CONTAX GSM will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.