[. . . ] [. . . ] All modules have added crossbars on the back side of the module for greater support and stability in harsh conditions, including high wind and snow load regions.
Quality Built In
· · · · · UV stabilized, aesthetically pleasing black anodized frame Supported by major mounting structure manufacturers Easily accessible grounding points on all four corners for fast installation Proven junction box technology with PV wire to work with transformerless inverters Quality locking plug-in connectors to provide safe & quick connections
·
Reliable
· · · Superior built-in quality Proven superior field performance Tight power tolerance
Warranty
UL Listing QIGU. E173074
NEC 2008 Compliant UL 1703, ISO 9001 and ISO 14001 Certified and Registered Class C Also available: QUALIFIED FOR "BUY AMERICAN"
Manufactured in San Diego, California
· · · ·
Kyocera standard 20 year power output warranty and 5 year workmanship warranty applies in USA Extended warranties available per project requirements Kyocera standard 20 year power output warranty and 2 year workmanship warranty applies outside of USA Refer to Kyocera warranty policy for details
KD 200-60 F Series
electrIcal SPECIFICATIONS
Standard Test Conditions
KD230GX-LFB
Pmp2 Vmp Imp Voc Isc Ptolerance
MecHaNIcal SPECIFICATIONS
4. 25in 108mm
KD235GX-LFB
KD240GX-LFB
11. 06in 281mm
230 29. 8 7. 72 36. 9 8. 36 +5/-3
235 29. 8 7. 89 36. 9 8. 55 +5/-3
240 29. 8 8. 06 36. 9 8. 59 +5/-3
W V A V
4. 13in 105mm
JUNCtION BOx
40. 55in/1030mm 32. 68in/830mm
CABLE w/ CONNECtOR
LABEL
stABILIzER BAR
%
21. 65in 550mm
Nominal Operating Cell Temperature Conditions (NOCT)
tNOct Pmax Vmp Imp Voc Isc
65. 43in 1662mm
A
21. 65in 550mm
stABILIzER BAR
45. 0 165 26. 8 6. 18 33. 7 6. 77
45. 0 169 26. 8 6. 31 33. 7 6. 92
45. 0 172 26. 7 6. 45 33. 7 6. 95
O
C
11. 06in 281mm
W V
37. 99(±0. 1)in 965±2. 5mm
A V A
. 49in 12. 5mm
Weight: 46. 3lbs (21. 0kg) 1. 8in 46mm
Temperature Coefficients
Pmax Voc Isc
Operating temp
-1. 04 -0. 133 0. 00502 -40~90
-1. 07 -0. 133 0. 00513 -40~90
-1. 10 -0. 133 0. 00515 -40~90
W/ C V/ C A/ C
O o o
o
C
System Design
Series Fuse Rating Maximum DC System Voltage (UL)
15 A 600 V
NEC 2008 Compliant UL 1703 Listed
Kyocera reserves the right to modify these specifications without notice. cell temperature, 1. 5 AM and 1000W/m2.
legend
MOUNtINg HOLEs DRAINAgE HOLEs gROUNDINg HOLEs
AUTHORIzED DISTRIbUTOR
KYOcera SOlar, INc.
111810
800-223-9580 toll-free
800-523-2329 fax
www. kyocerasolar. com [. . . ] [. . . ]