User manual CONTAX KD135SX-UPU DATASHEET

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual CONTAX KD135SX-UPU. We hope that this CONTAX KD135SX-UPU user guide will be useful to you.


CONTAX KD135SX-UPU DATASHEET: Download the complete user guide (948 Ko)

You may also download the following manuals related to this product:

   CONTAX KD135SX-UPU INSTALLATION (180 ko)
   CONTAX KD135SX-UPU MOUNTING GUIDE (133 ko)

Manual abstract: user guide CONTAX KD135SX-UPUDATASHEET

Detailed instructions for use are in the User's Guide.

[. . . ] [. . . ] Kyocera's Kaizen Philosophy, commitment to continuous improvement, is shown by repeatedly achieving world record cell efficiencies. Kyocera Quality Built In: - New frame technology allows for end mounting under 2400 Pa (50 psf) and traditional mounting under 5400 Pa (113 psf) to support increased snow load - UV stabilized, aesthetically pleasing black anodized frame - Supported by all major mounting structure manufacturers - Easily accessible grounding points on all four corners for fast installation - Proven junction box technology Kyocera manufactures and assembles solar cells and modules at its own worldwide production sites using a true vertical integration process. This superior approach gives Kyocera complete control over every step of the manufacturing process, producing modules with the industry's tightest power tolerance, promising high quality and efficiency. Built-In Quality for Off-Grid Applications Proven Superior Field Performance Tight Power Tolerance 20 Year Warranty 5 Year Workmanship Warranty KD135SX-UPU NEC 2008 Compliant UL1703, Class C CLASS I, DIV II KD135SX-UPU Current-Voltage characteristics of Photovoltaic Module KD135SX-UPU at various cell temperatures Current-Voltage characteristics of Photovoltaic Module KD135SX-UPU at various irradiance levels 9 9 Specifications Electrical Perfomance under Standard Test Conditions (*STC) Maximum Power (Pmax) Maximum Power Voltage (Vmpp) Maximum Power Current (lmpp) Open Circuit Voltage (Voc) Short Circuit Current (Isc) Max System Voltage Temperature Coefficient of Voc Temperature Coefficient of Isc *STC : Irradiance 1000W/m2, AM1. 5 spectrum, cell temperature 25° 135W (+5%/­5%) 17. 7V 7. 63A 22. 1V 8. 37A 600V ­8. 0x10-2 V/°C 5. 02x10 A/°C -3 Cells Number per Module Module Characteristics Length X Width X Depth Weight Junction Box Characteristics Length X Width X Depth IP Code 36 1500mm(59. 1in)x668mm(26. 3in)x46mm(1. 8in) 12. 5kg(27. 5lbs. ) 150mm(5. 9in)x140mm(5. 5in)x37. 2mm(1. 5in) IP65 Electrical Performance at 800W/m2, *NOCT, AM1. 5 Maximum Power (Pmax) Maximum Power Voltage (Vmpp) Maximum Power Current (lmpp) Open Circuit Voltage (Voc) Short Circuit Current (Isc) *NOCT (Nominal Operating Cell Temperature) :47. 9°C 95W 15. 7V 6. 10A 20. 0V 6. 79A Others *Operating Temperature Maximum Fuse *This temperature is based on cell temperature. ­40°~90°C 15A ISO 9001 and ISO 14001 Certified and Registered www. kyocerasolar. com 800-223-9580 toll free 800-523-2329 fax 06/29/10 [. . . ] [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE CONTAX KD135SX-UPU




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual CONTAX KD135SX-UPU will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.