User manual CONTAX PCB-180

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual CONTAX PCB-180. We hope that this CONTAX PCB-180 user guide will be useful to you.


CONTAX PCB-180 : Download the complete user guide (147 Ko)

You may also download the following manuals related to this product:

   CONTAX PCB-180 DATASHEET (40 ko)

Manual abstract: user guide CONTAX PCB-180

Detailed instructions for use are in the User's Guide.

[. . . ] If you need to change the voltage set point, the "panel voltage adjusting pot" will allow you to do so. CAUTION: If you change the voltage setting using the adjusting pot, it will change the set points on all 4 selector switches. SELECTOR SWITCH SETTINGS Switch 1 Used For Electrode Logic Off for High Water Cut-off On for Low Water Cut-off Off-Make Contact for Turn-off On-Break Contact for Turn-off No. Series Modules 9 10 11 12 Set Point 123 Volts 136 Volts 150 Volts 164 Volts 2 Remote Switch Logic Switch 3 4 5 6 Used For 135 Volt Panel Direct 150 Volt Panel Direct 165 Volt Panel Direct 180 Volt Panel Direct 12/07/99 2 LARGE WIRE TERMINAL BLOCK 1 2 3 4 PVLDLD+ PV+ NEGATIVE WIRE from the PV array. [. . . ] Switch #2 in the OFF position allows the pump to run when terminals 7 and 8 are disconnected. This is generally used in conjunction with a float switch which breaks contact to make the pump run. A QUALIFIED SOLAR ELECTRIC TECHNICIAN SHOULD ONLY PERFORM THIS PROCEDURE. THIS PROCEDURE IS NOT NECESSARY IF STANDARD 16. 5 TO 17 VOLT SOLAR MODULES ARE BEING USED. This procedure will not work on a centrifugal type pump such as an SCS submersible. The purpose of this procedure is to adjust the voltage of the PV array to its peak power point and thus obtain the maximum water delivery from the pump. This procedure should be performed with the panels at their normal operating temperature at mid-day. With the system installed and pumping water, turn the panels away from the sun until the pump flow rate is reduced by approximately 50%. If this is not-possible, then shade the panels slightly until you obtain the same results. This puts the controller in a current boosting mode so this adjustment can be made. (LD+ and LD-) Turn the small brass adjusting screw on the "Panel Voltage Adjusting Pot", located on the front of the controller, until the highest possible voltage is obtained. (If this controller is used on a Jack Pump system using a flywheel there will be a slight delay from the time you make an adjustment to when a change in voltage will be noticed. ) 4 2. The pump will then operate at its maximum output. (Option 2) For estimated panel voltage adjustment. With the system installed and pumping water, turn the panels away from the sun until the pump flow rate is reduced by approximately 50%. If this is not possible, then shade the panels slightly until you obtain the same results. This puts the controller in a current boosting mode so this adjustment can be made. (PV+ and PV-) Estimate the proper voltage by multiplying the voltage rating of the panel's times the number of panels connected in series and deduct 20%. = 205 Volts ­ 20% = 164 Volts Turn the small brass adjusting screw on the "Panel Voltage Adjusting Pot", located on the front of the controller, until the estimated voltage is obtained. 3. 4. 5. 12/07/99 5 TROUBLESHOOTING PUMP DOES NOT RUN If the pump does not run, first make sure the on/off switch is in the up position. The red light (indicating power in) and the green light (indicating power out) are the only ones that should be on. All other lights indicate that the controller has been turned off for a specific reason. If the solar panel wires are connected in reverse polarity the controller will short to ground. [. . . ] SOLARJACK shall have no responsibility for damage to property, persons, animals, or other loss or injury resulting from the use of this product. UNDER NO CIRCUMDSTANCES WILL SOLARJACK BE LIABLE FOR ANY INCIDENTAL OR CONSEQUENTIAL DAMAGE, UNLESS OTHERWISE EXPRRESSLY STATED HEREIN. SOLARJACK'S maximum liability under any warranty, expressed, or implied, or statutory, is limited to the purchase price of the product. This warranty is in lieu of all other warranties expressed or implied. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE CONTAX PCB-180




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual CONTAX PCB-180 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.