[. . . ] LYNCOM MODEL PV12T PV SYSTEM LIGHTING CONTROLLER
Lyncom's microprocessor based charge controllers incorporate state-of-the-art design and advanced pulse-width-modulation (PWM) battery charging operation, offering the highest quality and more features than comparably priced PV controllers. [. . . ] Model PV12T features an automatic load timer, which senses dusk by the solar array and initiates the lighting time period, which is field adjustable. When the timer circuit is `0' (defeated), PV12T can also be used as a continuous load controller with LVD. The Model PV12T lighting timer operation can be pre-set from 0 to 10 hours continuously adjustable or from dusk to dawn. A low battery voltage load disconnect circuit (LVD) prevents battery over-discharge during extended overcast periods. The PV12T has three system status LED's: system charging, battery full and battery low. The reverse polarity protection circuit features a reverse polarity red LED for PV or battery, ensuring proper hook up.
Standard Features
· Advanced solid state design · On-board microprocessor to control voltage settings and parameters accurately · Pulse-width-modulation charge algorithm to extend battery life compared to · · · · · · · · ·
conventional "on-off" type controllers Temperature compensation circuit to automatically adjust the optimum battery regulation voltage and LVD voltage for a range of -30°C to +80°C Lightning transient protection PV and battery reverse polarity protection Over-voltage protection Over-temperature protection Selection of battery type between flooded and sealed Automatic battery equalization for flooded battery Parallel capability 5 year limited warranty
Ratings
· · · ·
Battery Voltage: Maximum PV current: Maximum Load current: Self-Consumption: 12 Volts 12. 0 Amps 12. 0 Amps 13. 0 mA
LYNCOM MODEL PV12T PV SYSTEM LIGHTING CONTROLLER
Temperature Setpoints
· High Temperature Shutdown:
Disconnect PV: Disconnect Load: Reconnect PV: Reconnect Load: Operating Temperature Range: Temperature Compensation Coefficient: Cold Temperature Load Cutoff: Reconnect of Cold Temperature Load Cutoff: 70°C 80°C 60°C 50°C -40°C to +80°C -4mV/Cell/C° -30°C -20°C
· · · ·
Control Setpoints
Sealed Flooded Battery Battery
· High Battery Voltage System · · · · · · ·
Shutdown (8 seconds): Reset For High Voltage Shutdown (Instantly): Battery Equalization: Regulation Voltage: Battery LVD Voltage (32 seconds): Load Reconnect After Low Voltage Disconnect (LVD) (Instantly): Automatic equalization: Equalization can be triggered (32 seconds): 15. 5 V 14. 5 V 14. 1 V 11. 3 V 12. 8 V 15. 5 V 14. 5 V 15. 3 V 14. 4 V 11. 4 V 13. 0 V 14 days V<11. 4V
Microprocessor Sampling Period
· · · ·
PV Voltage Sampling: Battery Voltage Sampling: Temperature Sampling: Load Current Sampling After Over-Current Sampling: 8 seconds Constantly 3 seconds 3 - 6 seconds
Other Specifications (All ratings at 25°C)
· Weight: · Dimensions: · Voltage Drop PV/Battery:
6 oz. [. . . ] (14. 48 x 6. 6 x 5. 33 cm) 0. 17 Volts
7812 EAST ACOMA DRIVE SCOTTSDALE, AZ 85260 USA 480/951-6330 · 800/544-6466 FAX: 480/951-6329 www. kyocerasolar. com e-mail: info@kyocerasolar. com
Specifications subject to change without notice. [. . . ]