[. . . ] System Status: Float Charging
RC7 RC7GS
Installation and Operator's Manual
Xantrex RV Series Remote Controls
RC7 & RC7GS Remote Controls
Notice of Copyright Xantrex RC7 and RC7GS Remote Controls Installation and Operator's Manual © October 2002 Xantrex International. Disclaimer UNLESS SPECIFICALLY AGREED TO IN WRITING, XANTREX TECHNOLOGY INC. ("XANTREX") (a) MAKES NO WARRANTY AS TO THE ACCURACY, SUFFICIENCY OR SUITABILITY OF ANY TECHNICAL OR OTHER INFORMATION PROVIDED IN ITS MANUALS OR OTHER DOCUMENTATION. (b) ASSUMES NO RESPONSIBILITY OR LIABILITY FOR LOSS OR DAMAGE, WHETHER DIRECT, INDIRECT, CONSEQUENTIAL OR INCIDENTAL, WHICH MIGHT ARISE OUT OF THE USE OF SUCH INFORMATION. [. . . ] NOTE: The generator will start immediately if the auto-start parameters are still met.
On / Off
Gen Start / Stop: Press (ON / OFF)
822-4A-004
Figure 29 Generator Start/Stop (on User Menu)
16
RC7 & RC7GS Remote Controls 3. 0 OPERATION
5. Begin Gen Quiet and End Gen Quiet The period of time during which the generator is prevented from starting automatically can be defined using the RC7GS. To specify the begin quiet time, scroll to the Begin Gen Quiet: 00:00 by using the UP and DOWN arrow push-buttons. The selected digit for hours or minutes will be underlined and highlighted (refer to the Set Clock section for details on setting the time).
Begin Gen Quiet 00:00
Figure 30 Start Generator Quiet Time Press the DOWN arrow to access the End Gen Quiet: 00:00 menu and select the appropriate end time.
End Gen Quiet 00:00
Figure 31 End Generator Quiet Time
NOTE: Setting begin and end time to 00:00 defeats the quiet time mode. NOTE: If the generator is running at the begin quiet time, it will be shut down automatically. If the auto-start parameters are met during quiet time, the buzzer will sound and the LCD displays the message "Gen Quiet Fault. " The generator will start automatically at the end of the quiet time.
17
RC7 & RC7GS Remote Controls 3. 0 OPERATION Saving Setup Choices
Once the setup options are complete, press and hold both the UP and DOWN arrow push-buttons until the display clears (approximately 5 seconds). The setup choices will be saved in nonvolatile memory 20 seconds after exiting the Setup menu if no other actions are taken. NOTE: The GenStart settings will not be saved if the RC7GS is disconnected or dc power is lost.
Menu Item
Setup
Meter Mode
822-4A-005
Figure 32 Press and Hold to Save Settings
18
RC7 & RC7GS Remote Controls 3. 0 OPERATION RC7 and RC7GS System Status Displays
The RC7 and RC7GS remote controls display the operating mode and system status by lighting one or more LEDs located on the front panel and/or by displaying a message on the LCD display. The four LEDs reflect the same information as the single tricolored LED on the inverter/charger. There are four types of system messages: · AC source messages · Inverter messages · Charger messages · Error messages
AC Source Messages
AC source messages appear when alternating current (shorepower) is present. In addition, the RC7GS AC source messages describe the current activity, if any, of the generator. Waiting for AC Anytime the inverter is OFF and AC is not present, the LCD screen displays "Waiting for AC. " 1.
System Status: Waiting for AC
Figure 33 Waiting for AC
2.
Genset Status: Pending, Cranking and Genstart When the RC7GS is setup to start the generator for a specified condition (SOC or battery voltage) and that condition has been met, the LCD displays "Pending Genstart. "
Genset Status: Pending Genstart
Figure 34 Pending Genstart Messages When the initiating condition (SOC or battery voltage) has occurred, the Pending Genstart message is displayed for approximately two minutes awaiting a change in the condition or a manual override. If neither condition occurs, the RC7GS attempts to start the generator and displays "Cranking Genset. "
Genset Status: Cranking Genset
Figure 35 Cranking Genset Messages
19
RC7 & RC7GS Remote Controls 3. 0 OPERATION
Once the generator starts, there is a brief delay to allow the genset to reach operating speed and for the inverter/charger to synchronize to the generator, at which point the LCD display shows that AC is again available.
Genset Status: AC Available
Figure 35 Cranking Genset Messages Starter Cooldown and Gen Start In the event the genset does not start within 30 seconds, a two-minute starter cooldown message is displayed after which another attempt to start the generator occurs. This cycle repeats itself three more times over a 12-minute period.
Genset Status: Starter Cooldown
3.
Figure 36 Starter Cooldown Messages
Gen Set Error Messages
Gen Won't Start If the genset does not start after the four attempts, the RC7GS displays the message "Gen Won't Start" and the red Error LED on the front panel lights. Correct the starting problem and manually start the genset by setting the RC7GS to "Manual (Push On)" from the setup menu and then set it back to the previous auto-start menu, which resets the RC7GS.
Inverter Charge Batt. Full Error
822-4A-001
1.
Genset Status: Gen wont Start Buzzer Sounds Red Error LED lights and error message appears in the LCD display
Figure 37 Gen Won't Start Error Message NOTE: Press any arrow push-button to cancel the buzzer. Gen Quiet Fault Whenever the RC7GS is configured to Auto Start the generator under a specified condition and the condition occurs during the gen quiet period, the LCD will display the Gen Quiet Fault message and the red Error LED will light. The remote control also emits a series of beeping sounds for up to five minutes or until the error condition is corrected. The gen quiet period can be overridden by resetting the Gen Quiet Begin and End time to 00:00.
20
RC7 & RC7GS Remote Controls 3. 0 OPERATION
Inverter Charge Batt. Full Error
822-4A-001
Genset Status: Gen Quiet Fault
Buzzer Sounds
Red Error LED Lights and Error Message Appears in the LCD Display and buzzer sounds.
Figure 38 Gen Quiet Fault Error Message NOTE: Press any arrow push-button to cancel the buzzer. NOTE: If the genset is manually started from the RC7GS remote, a manual override is initiated and it will not shut down automatically. NOTE: The Gen Quiet Fault error is not actually a system error or fault but rather an alert that the system has reached the selected auto-start parameter during the quiet time selected.
Genset Status: Man Stop Only!!
Figure 39 Genset Manual Stop Only Display The Gen Quiet Fault error is automatically reset at the end of the quiet time period if no other action is taken.
Low AC Input V The Low AC Input V Fault error indicates the input AC voltage is below 45 V AC (B+ is presentPower Tech generators only). [. . . ] For some products, Xantrex maintains a network of regional Authorized Service Centers. Call Xantrex or check our website to see if your product can be repaired at one of these facilities. In any warranty claim, dated proof of purchase must accompany the product and the product must not have been disassembled or modified without prior written authorization by Xantrex. Proof of purchase may be in any one of the following forms: · The dated purchase receipt from the original purchase of the product at point of sale to the end user, or · The dated dealer invoice or purchase receipt showing original equipment manufacturer (OEM) status, or · The dated invoice or purchase receipt showing the product exchanged under warranty What does this warranty not cover? [. . . ]