User manual CONTAX SW 2548 REV A
DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual CONTAX SW 2548. We hope that this CONTAX SW 2548 user guide will be useful to you.
Manual abstract: user guide CONTAX SW 2548REV A
Detailed instructions for use are in the User's Guide.
[. . . ] Smart choice for power
SW 2524 SW 2548
Owner's Manual
Sine Wave Plus Inverter/Charger
www. xantrex. com
Sine Wave Plus Inverter/Charger
Owner's Manual
About Xantrex
Xantrex Technology Inc. is a world-leading supplier of advanced power electronics and controls with products from 50 watt mobile units to one MW utility-scale systems for wind, solar, batteries, fuel cells, micro turbines, and backup power applications in both grid-connected and stand-alone systems. Xantrex products include inverters, battery chargers, programmable power supplies, and variable speed drives that convert, supply, control, clean, and distribute electrical power.
Trademarks
Sine Wave Plus Inverter/Charger is a trademark of Xantrex International. Other trademarks, registered trademarks, and product names are the property of their respective owners and are used herein for identification purposes only.
Notice of Copyright
Sine Wave Plus Inverter/Charger Owner's Manual © June 2003 Xantrex International. [. . . ] When the AC voltage reaches this level, the inverter stops battery charging and operates in parallel (in the inverter mode) with the AC source, to aid the utility power to meet the demands of the load. If the voltage drops below this level, the inverter disconnects the AC source and powers the load directly from the batteries as long as the inverter's selection in 01A Inverter is ON or SRCH. Guidelines for setting this menu item: · Ensure this value is within the lower limits of any AC operated equipment connected to the inverter.
CAUTION: Damage to Loads
Adjusting upper and lower AC voltage parameters allows the higher and lower voltages than the inverter output to pass through to connected AC loads. Ensure that all connected AC loads will not be damaged by the higher and lower settings.
624
976-0043-01-01
Menu Item Descriptions
14 Save/Restore Settings Menu
14 Save/Restore Settings Menu
This menu provides the means to: · · · save user programmed settings, restore previously saved programmed settings, or to restore factory default settings.
If DC power is removed from the inverter, all user defined setpoints will be intact if they were saved before the power was removed. If new settings are not saved, the inverter will restart with the last saved setpoints or with the factory defaults (if none were ever saved).
Note: The settings in this menu are identical to Menu 27. Saving or
restoring settings at either menu will apply to all menu settings (Basic and Advanced).
14A Push INV now to Save Settings
14A Push INV now to save settings
This menu item provides the means to save settings currently programmed into the inverter. Press the red INV button to save the settings.
14B Push GEN to Restore Settings
14B Push GEN to restore settings
This menu item provides the means to restore settings previously set and saved on the inverter. Press the green GEN button to restore previously programmed settings.
976-0043-01-01
625
Basic Setup Programming
14C Push GEN for factory defaults
14C Push GEN for factory defaults
This menu item provides the means to restore the factory default settings. Press the green GEN button to restore the factory default settings.
End Basic Setup Menu
END BASIC SETUP MENU
You have reached the end of the Basic Setup Menu. Press the Menu Heading button until END BASIC SETUP MENU is displayed. This will move you forward to the ADVANCED USER SETUP MENU.
626
976-0043-01-01
7
Advanced Setup
Chapter 7, "Advanced Setup" explains how to program the Sine Wave Plus Inverter/Charger to operate under special, advanced conditions, such as automatic generator starting, energy management and auxiliary load applications.
Advanced Setup
Advanced Setup Summary
The following table provides the default settings for the Sine Wave Plus Advanced Setup Menu and cross-reference pages for locating information on each menu item. If your system requires changes to these default settings, record the changes in Table B-3, "Advanced Setup Default and User Settings" on page B7 before your start programming. For information on each of the Menu Items see the corresponding cross-reference page listed in Table 71. For directions on how to get to the Advanced Setup Menu, see "Accessing the Advanced Setup Menu" on page 76. Table 7-1 Advanced Setup Menu Headings and Default Settings
Sine Wave Plus 2524 Advanced Setup Menus 20 Silent Setup Menu 20A Refloat High Volts DC 20B Refloat Low Volts DC 20C Float Done Amps AC 20D Must Float Time Min End Menu 20 21 Grid AC1 Usage Menu 21A Grid Usage 21B Grid Usage Begin h:m 21C Grid Usage End h:m End Menu 21 22 Battery Xfer (BX) Menu 22A High Xfer (HBX) Vdc 22B Low Xfer (LBX) Vdc End Menu 22 23 ALM Relays Menu 23A RY9 VDC Energized 23B RY9 VDC DeEnergized See "23 ALM Relays Menu" on page 714 for details. 22. 1 - 35. 5 20. 0 - 35. 5 26. 0 22. 0 44. 2 - 71. 0 40. 0 - 71. 0 52. 0 44. 0 page 715 page 715 See "22 Battery Xfer (BX) Menu" on page 713 for details. 16. 1 - 33. 9 16. 1 - 33. 8 27. 0 23. 0 32. 2 - 67. 8 32. 2 - 67. 8 54. 0 46. 0 page 714 page 714 See "21 Grid (AC1) Usage Menu" on page 711 for details. SB BX SB SB BX SB page 712 page 712 page 713 Range/ Display Default Settings Sine Wave Plus 2548 Range/ Display Default Settings See Page
See "20 Silent Setup Menu" on page 78 for details. 16. 1 - 33. 9 16. 1 - 33. 8 00 - 40 00 - 255 28. 4 25. 0 10 04 32. 2 - 67. 8 32. 2 - 67. 8 00 - 40 00 - 255 28. 4 25. 0 10 05 page 710 page 710 page 710 page 710
00:00 - 23:50 21:00 00:00 - 23:50 21:00
00:00 - 23:50 21:00 00:00 - 23:50 21:00
72
976-0043-01-01
Advanced Setup Summary
Table 7-1 Advanced Setup Menu Headings and Default Settings
Sine Wave Plus 2524 Advanced Setup Menus 23C RY9 Delay at DeEngz. Min 23D RY10 VDC Energized 23E RY10 VDC DeEnergized 23F RY10 Delay at DeEngz. Min 23G RY11 Mode End Menu 23 24 Generator Timers Menu 24A Gen Run Time Start h:m 24B Gen Run Time Stop h:m 24C Quiet Time Begin h:m 24D Quiet Time End h:m 24E Gen Exercise Period Days 24F Gen Exercise Timer Min 24G Gen Cooldown Timer Min 24H RN2/Max Gen Run h:m End Menu 24 25 Gen Starting Details Menu 25A RY7 Mode 25B Gen Warm-up Second/Minute 25C Pre Crank Seconds 25D Max Cranking Seconds 25E Post Crank Seconds End Menu 25 26 Gen Auto Run Setup Menu 26A Load Start Amps AC 26B Load Start Delay Min See "26 Gen Auto Run Setup Menu" on page 733 for details. 00 - 63 s 00. 0 - 25. 5 20 05. 0 00 - 36 00. 0 - 25. 5 20 05. 0 page 733 page 733 See "25 Gen Starting Details Menu" on page 724 for details. [. . . ] WITHOUT LIMITING THE GENERALITY OF THE FOREGOING, XANTREX MAKES NO REPRESENTATIONS OR WARRANTIES REGARDING THE USE OF THE XANTREX SINE WAVE PLUS INVERTER/CHARGER IN CONNECTION WITH LIFE SUPPORT SYSTEMS OR OTHER MEDICAL EQUIPMENT OR DEVICES.
Please note that the Sine Wave Plus Inverter/Charger is not intended for use as an uninterruptible power supply and Xantrex makes no warranty or representation in connection with any use of the product for such purposes.
Return Material Authorization Policy
Before returning a product directly to Xantrex you must obtain a Return Material Authorization (RMA) number and the correct factory "Ship To" address. Product shipments will be refused and returned at your expense if they are unauthorized, returned without an RMA number clearly marked on the outside of the shipping box, if they are shipped collect, or if they are shipped to the wrong location. When you contact Xantrex to obtain service, please have your instruction manual ready for reference and be prepared to supply: · The serial number of your product · Information about the installation and use of the unit · Information about the failure and/or reason for the return · A copy of your dated proof of purchase Record these details in on page I5.
976-0043-01-01 I3
Return Procedure
1. Package the unit safely, preferably using the original box and packing materials. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE CONTAX SW 2548
Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual CONTAX SW 2548 will begin.