User manual CONTAX TRACE DR REV A

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual CONTAX TRACE DR. We hope that this CONTAX TRACE DR user guide will be useful to you.


CONTAX TRACE DR REV A: Download the complete user guide (10115 Ko)

Manual abstract: user guide CONTAX TRACE DRREV A

Detailed instructions for use are in the User's Guide.

[. . . ] DR Series Inverter/Charger Installation & Operators Manual DR Series Inverter/Charger Table of Contents Section 1. 0 Description Page INTRODUCTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Unpacking and Inspection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Certification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ] Recheck all connections. Refer to the illustration on the next page. 32 2000 Xantrex Technology Inc. 2. 0 INSTALLATION Generators (continued) Utility Power 120 VAC Bonded Neutral/ Ground Bus G R O U N D NEUTRAL HOT Main Utility Circuit Breaker N E U T R A L NEUTRAL Bond Wire Inverter Circuit Breaker HOT Utility Service Panel House Ground GENERATOR HOT CONTACT UTILITY HOT CONTACT COMMOMN CONTACT (to inverter) Manual Transfer Switch U C G HOT NEUTRAL Isolated Neutral Bus Manual Start Generator Generator Power AC Input Inverter AC Output Isolated Neutral Bus Main Input Breaker Isolated Neutral Bus NEUTRAL HOT GROUND To AC Load Sub-panel 975-0012-008 Figure 27 Basic 120 VAC Utility/Generator Block Diagram 2000 Xantrex Technology Inc. 33 2. 0 INSTALLATION Series Stacking This COM port allows two DR Series inverter/chargers to be used in the same system in a SERIES configuration to operate 240 VAC loads. Series stacking can also be used to connect to 240 VAC only power systems providing both 120 and 240 VAC outputs. A series stacking interface cable (DRI) is required to connect the series stacking port of the inverters. In this mode, one of the inverters will function as the primary and the other inverter becomes the secondary. The first unit switched ON becomes the primary and ensures the secondarys output is 180 degrees out of phase for 240 VAC operation. Both units can charge the batteries or provide battery backup power during a utility outage. The following illustrations provide a general overview of AC and DC wiring configurations and output voltages supplied by stacked inverters. Detailed wiring and operating instructions are provided with the DRI interface kit available from Xantrex Technology Inc. NOTE: Only 120 VAC/60 Hz models can be stacked. MAIN PANEL L1 L2 L1 N E U T R A L BOND WIRE GROUND HOT L1 L2 HOT L2 NEUTRAL IN HOT OUT NEUTRAL OUT NEUTRAL IN HOT IN DRI COM PORT GROUND NEUTRAL OUT GROUND INVERTER 1 (L1) SERIES STACKING CABLE (DRI) HOT OUT NEUTRAL OUT NEUTRAL IN HOT IN DRI COM PORT GROUND NEUTRAL OUT INVERTER 2 (L2) L1 N E U T R A L L2 L1 240 VAC SUB-PANEL GROUND L2 120 VAC 120 VAC GROUND 975-0012-D-014 Figure 28 Series Stacking AC Wiring (120 VAC/60 Hz models only) 34 2000 Xantrex Technology Inc. 2. 0 INSTALLATION Series Stacking (continued) Inverter 1 (L1) Positive Tie Negative Tie Series Stacking Cable (DRI) DC Disconnect Inverter 2 (L2) + + 975-0012-009 + + Figure 29 Stacking Port and Battery Wiring with One Disconnect (120 VAC/60 Hz models only) Inverter 1 (L1) Negative Tie DC Disconnect Series Stacking Cable (DRI) Inverter 2 (L2) + DC Disconnect + 975-0012-010 + + Figure 30 Stacking Port and Battery Wiring with Two Disconnects (120 VAC/60 Hz models only) 2000 Xantrex Technology Inc. 35 3. 0 OPERATION Front Panel Controls and Indicators All operating controls, indicators and sense connectors are located on the front panel of the unit. The controls are easily accessible, and the LEDs provide inverter/charger status at a glance. POWER ON/OFF Switch The POWER ON/OFF control is a momentary contact switch that turns the inverter/charger ON or OFF by pressing it once. When the inverter is first connected to the batteries, it will run through a self test consisting of flashing the LEDs in sequence, operating the cooling fan momentarily and switching the transfer relay three times. Once the self test has successfully completed, the POWER ON/OFF switch is activated. Both ports are RJ11 type telephone style connectors and are used for controlling the inverter and regulating the charger voltage based on temperature. Its primary function is to provide serial communications to an optional Trace remote control unit (RC4 or RC8). The port also acts as a stacking interface control when two DR Series inverters are used in a series configuration. When two inverters are stacked, a remote control cannot be used with either unit. Remote Controls (RC4 or RC8) DR Series inverters are designed to operate with either an RC4 or RC8 remote control units. Both remotes incorporate a membrane switch with a single red LED display combination to start and stop the inverter, as well as provide overall system operating status. Solid With AC line power present, the unit is charging the batteries while directing AC to the load. With no AC line power present, the inverter is running on the batteries and supplying AC to the load. Blinking Slow (1 to 3 flashes @ 1 second intervals) The inverter is in search mode (no load connected). [. . . ] Some states or counties do not allow limitations on the term of an implied warranty, or the exclusion or limitation of incidental or consequential damage, which means the limitations and exclusions of this warranty may not apply to you. Even though this warranty gives you specific legal rights, you may also have other rights which vary from state to state. Xantrex Technology Inc. , 5916 195th Northeast, Arlington, WA 98223, U. S. A. t: 360/435. 8826, f: 360/435. 3945 www. xantrex. com 2000 Xantrex Technology Inc. 69 6. 0 WARRANTY Life Support Policy Xantrex does not recommend the use of any of its products in life support applications or direct patient care. This especially applies to situations where the products failure or malfunction can be reasonably expected to cause the failure or malfunction of the life support device, or to significantly affect its safety or effectiveness. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE CONTAX TRACE DR




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual CONTAX TRACE DR will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.