User manual EARLEX SPRAY STATION PRO HV 5000

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual EARLEX SPRAY STATION PRO HV 5000. We hope that this EARLEX SPRAY STATION PRO HV 5000 user guide will be useful to you.


EARLEX SPRAY STATION PRO HV 5000 : Download the complete user guide (268 Ko)

Manual abstract: user guide EARLEX SPRAY STATION PRO HV 5000

Detailed instructions for use are in the User's Guide.

[. . . ] Only use the unit as detailed in these instructions. TECHNICAL SPECIFICATION Supply Voltage Rated Input Airflow (motor) Cable Length Hose Length 230V (50Hz) 800 Watts 1550 ltr/min 1. 7m 4m Output control Spray Gun Weight (empty) Container Capacity Appliance Class 690g/min (water) 1100gms 1 Litre Class 2, double insulated 2 L0199 09-04. qxd 14/2/05 10:13 am Page 3 SPARE PARTS DRAWING The following parts are available from Earlex. 14. Air Cap Ring Air Cap Air Distributor Plate Assy Fluid Tip, 2. 0mm Fluid Tip Seal Pivot Screw Washer Main Body Assy Fluid Needle 2. 0mm Adaptor Spring Adjusting Screw Pivot Air Feed Tube L0151 L0152 L0162 L0157 L0159 L0179 L0195 L0180 L0166 L0174 L0175 L0176 L0178 L0182 SPARE PARTS LIST Part No. 28. Gland Nut Gland Washer (2 pcs) Paint Container Centre Bolt Nut Gasket Lid Assy Shim Clamp Lever Yoke Centre Bolt & Pick Up Tube Assy Operating Lever Viscosity Cup Spanner Motor Unit (not available) L0173 L0168 L0190 L0189 L0188 L0187 L0186 L0185 L0184 L0183 L0177 SG243 L0191 L0228 Part No. OPTIONAL EXTRAS Needles & Fluid Tips of different sizes can be obtained as sets under the following accessory numbers. 1. 0mm dia Fluid Tip, needle & seal L0224 2. 0mm dia Fluid Tip, needle & seal L0226 1. 5mm dia Fluid Tip, needle & seal L0225 2. 5mm dia Fluid Tip, needle & seal L0227 3 L0199 09-04. qxd 14/2/05 10:13 am Page 4 INTRODUCTION HVLP stands for High Volume, Low Pressure. [. . . ] Unwind the hose from the main housing and connect to the back of the gun. ALWAYS KEEP THE MOTOR UNIT AS FAR AWAY FROM THE SPRAYING AREA AS POSSIBLE TO PREVENT PAINT CONTAMINATING THE MOTOR. No paint will be sprayed from the gun until the trigger on the spray gun is pulled. Before starting any work on spraying actual objects we suggest you spend a small amount of time practicing on cardboard or newspaper until you have got used to how the gun works. OPERATION SPRAY PATTERNS The gun has 3 different spray patterns ­ Horizontal, Vertical and Round (Fig. 2). The round spray is used for small objects or for areas - such as corners ­ that are difficult to reach. Fig. 2 To change the spray pattern simply rotate the Air Cap (2) until it clicks into the positions as shown in (Fig 2). The overall size of the selected spray pattern can be varied by turning the Air Cap Ring (1). When viewed from the front, rotate Horizontal Jet Round Jet it clockwise to increase the pattern size, or anti-clockwise to Vertical Jet reduce the pattern size. The volume of paint sprayed is easily adjustable (Fig. 3). Completely close adjustment screw (12) by turning this clockwise as far as it will go. Whilst pulling the trigger, begin turning the adjustment screw anti-clockwise until the volume of paint you require is obtained. If the paint spray contains too much paint turn the adjustment screw clockwise to reduce it. Once you have set the spray pattern & the paint volume, you are ready to begin spraying. Fig. 3 PAINT VOLUME 1. To obtain the best results always keep your spray gun level and spray equally from side to side or up or down from the surface. Avoid spraying at an angle as this will lead to runs on the surface (Fig. 4). Let your arm control the left to right movement rather than your wrist as this will aid even paint distribution over the whole area (Fig. 5). Do not tip the spray gun to more than 45°angle (Fig. 6). SPRAYING TECHNIQUE Fig. 4 Fig. 5 Fig. 6 NEEDLE & FLUID TIP SELECTION Paints, varnishes, wood treatments etc, are manufactured using a variety of materials & have widely different viscosities. You may find that the 2. 0mm dia Fluid Tip & Needle supplied with this spray gun does not enable you to spray your particular choice of finish exactly as you would like. In such cases a change of Fluid Tip & Needle size will probably solve this problem. In general, thicker, more viscose materials are best sprayed through a larger Fluid Tip to give best coverage. Thinner, less viscose materials are best sprayed through a smaller Fluid Tip. To allow for these variations Fluid Tip & needle sets are available, as optional extras, in 1. 0mm dia, 1. 5mm dia & 2. 5mm dia (See page 3). 5 L0199 09-04. qxd 14/2/05 10:13 am Page 6 HELPFUL HINTS 1. [. . . ] If you are using an extension lead it must be rated at a minimum of 6 amps and fully unwound. Do not operate with a lead rated at less than 6 amps as this will cause premature failure of the motor which is not covered by the guarantee. As the colours of the wires in the mains lead of the application may not correspond with the coloured markings identifying the terminals in your plug, proceed as follows: The wire which is coloured blue must be connected to the terminal which is marked with the letter N or coloured black. The wire which is coloured brown must be connected to the terminal which is marked with the letter L or coloured red. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE EARLEX SPRAY STATION PRO HV 5000




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual EARLEX SPRAY STATION PRO HV 5000 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.