User manual EXHAUSTO EBC20

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual EXHAUSTO EBC20. We hope that this EXHAUSTO EBC20 user guide will be useful to you.


EXHAUSTO EBC20 : Download the complete user guide (4173 Ko)

Manual abstract: user guide EXHAUSTO EBC20

Detailed instructions for use are in the User's Guide.

[. . . ] 3002878-2011-01-14 GB EBC20 Instructions for fitting, installation and operation Job name: __________________________________ Fitter: ______________________________________ Installation date: ______________________________ EXHAUSTO CDT A/S www. exhausto-cdt. com 3002878-2011-01-14 1. Product information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 1. 1 1. 2 1. 3 1. 4 Delivery . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Fitting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 1. 3. 1 Cable length. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 1. 3. 2 Connection diagram. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Layout of the user interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 1. 4. 1 Panel. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 1. 4. 2 Light emitting diodes and terminal board . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 1. 4. 3 Display . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 Introduction to the user interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 Set-up . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 1. 6. 1 Setting the chimney draft . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ] The three operating functions are: 1 Pressure-controlled regulation of EXHAUSTO CDT chimney fans (default) 2-stage speed regulation of EXHAUSTO CDT chimney fans Pressure-controlled regulation of EXHAUSTO CDT supply air fan symbol is changed 2 3 5 ·Press 6 Tofinishandreturntotheoperationscreen, press . RESET ·Press ·Press to go to menu 1 OK to go to menu 10 to go to menu 11 OK OK toconfirmandsaveselection 14 / 40 3002878-2011-01-14 Pressure-controlled regulation of EXHAUSTO CDT chimney fan 2. Pressure-controlled regulation of EXHAUSTO CDT chimney fan 2. 1 Use Area of use ·The EBC20 is designed for use with boiler systems with 1- and 2-stage burners. ·The EBC20 can also be used for boiler systems with modulating burners. ·The control system is intended for: > solid fuel boilers > atmospheric gas boilers > forced draft boilers for oil and gas > condensing boilers ·The EBC20 can control a chimney fan directly or indirectly via a frequency converter. 2. 2 Method of operation General function ·The control system monitors chimney draft and disconnects the burner in the event of errors (the alarmdiode on the EBC20 will turn on). ·When the boiler thermostat demands heat, the chimney fan will start at max. ·WhentheEBC20registerssufficientchimneydraft, theburnerisreleased. ·The EBC20 maintains the set pressure by regulating the voltage. ·Intheeventofaninsufficientpressuretheburnerwillbedisconnectedafter15seconds. "Insufficientpressure"islessthan64%ofthesetvalue, correspondingless than80%flow. ·When the boiler switches off, the chimney fan is also stopped. However, it is possible to set a post-purge period for the chimney fan (see page 22). Alternatively, the control system can be set up to keep the chimney fan running continuously (see page 21). Light emitting diodes and output signals All inputs and outputs are linked to light emitting diodes for the monitoring and service of the system (1. 4. 2 Light emitting diodes and terminal board, page 8 ). The EBC20 has 0­10V output signals for controlling multiple chimney fans via frequency converters or motor power relays. 2. 3 Electrical connection Thisworkmustbeperformedbyaqualifiedelectricalengineer, inaccordancewith locally applicable rules and legislation. ! Isolation switch The installation of the supply cable must be carried out in accordance with applicable regulations and legislation. When connecting pressure transducer (XTP) and frequency converter, shielded cable must be used. EXHAUSTO CDT stresses that according to EU's Machinery Directive an isolation switch mustbesetupinthefixedinstallation. Available as an extra. 15 / 40 3002878-2011-01-14 Pressure-controlled regulation of EXHAUSTO CDT chimney fan 2. 4 Sample wiring diagrams As a constant pressure regulator for EXHAUSTO CDT chimney fans, the EBC20 can be connected to a range of different signals. The following pages are sample wiring diagrams, and show the following: · 2. 4. 1 Single- or two boiler application, page 17 · 2. 4. 2 Single boiler application with potential free contact in boiler, page 18 · 2. 4. 3 Single boiler application with extra fail-safe protection using PDS, page 19 · 2. 4. 4 Single boiler application with a frequency converter, page 20 · 2. 4. 5 2 boiler application with continuous operation of chimney fan, page 21 ! EXHAUSTO CDT recommends that you contact the boiler manufacturer for details of correct connection of the boiler control system. 16 / 40 3002878-2011-01-14 Pressure-controlled regulation of EXHAUSTO CDT chimney fan 2. 4. 1 Single- or two boiler application This example shows how to connect a voltage signal (18­230 V AC/DC) for the EBC20 to start/stop the fan from one or two independent boilers: ·Connect the supply voltage to terminals 1­3 ·Connecting the boilers: - Connect the burner start signal (L) to terminal 11 & 15 - Connect the neutral wire to terminal 12 & 16 - The start signal for the burner is sent from terminal 14 & 18 ·Loop terminals 11 and 13 ·Loop terminals 15 and 17 ·Connect the chimney fan to terminals 4­6 ·Connect the pressure transducer (XTP) to terminals 23­25 17 / 40 3002878-2011-01-14 Pressure-controlled regulation of EXHAUSTO CDT chimney fan 2. 4. 2 Single boiler application with potential free contact in boiler This example shows how to connect a potential free contact to the EBC20 to start/stop the fan: ·Connect the supply voltage to terminals 1­3 ·Connection to the boiler: - Connect the potential free contact to terminals 11 & 19 - Loop terminals 12 & 20 - Connect the burner start signal to terminals 13 & 14 ·Connect the chimney fan to terminals 4­6 ·Connect the pressure transducer (XTP) to terminals 23­25 18 / 40 3002878-2011-01-14 Pressure-controlled regulation of EXHAUSTO CDT chimney fan 2. 4. 3 Single boiler application with extra fail-safe protection using PDS This example shows how to connect a PDS to the EBC20. The PDS carries out extra fail-safe protection. ·Connecting a PDS: - Removethefactoryfittedloopbetweenterminals26and28 - Connect the PDS between terminals 26 and 28 ·Connect the supply voltage to terminals 1­3 ·Connect the burner startsignal (-) to terminal 12 ·The start signal to the burner comes back on terminal 14 ·Connect the burner start signal (+) to terminal 11 ·Loop terminals 12 and 13 ·Connect the chimney fan to terminals 4­6 ·Connect the pressure transducer (XTP) to terminals 23­25 ·Set the value in menu 31 to 1 (PDS connected). ·NB: If 19 / 40 3002878-2011-01-14 Pressure-controlled regulation of EXHAUSTO CDT chimney fan 2. 4. 4 Single boiler application with a frequency converter This example shows which inputs/outputs on the EBC20 need to be connected to a frequency converter if the chimney fan is to be controlled by such a unit: ·Connect the supply voltage to terminals 1­3 ·Frequency converter: - Connect terminals 7 & 8 to the start/stop input on the frequency converter - Connect terminals 21 & 22 to the frequency converter input for external speed regulation - Terminals 26 and 28 can be connected to the frequency converter alarm output ·Connect the pressure transducer (XTP) to terminals 23­25 ·Connecting the boiler: - Connect the burner start signal (L) to terminal 11 - Connect the neutral wire to terminal 12 - Loop terminals 11 and 13 - The start signal for the burner is sent from terminal 14 20 / 40 3002878-2011-01-14 Pressure-controlled regulation of EXHAUSTO CDT chimney fan 2. 4. 5 2 boiler application with continuous operation of chimney fan This example shows how to connect the EBC20 if you require continuous operation of the chimney fan from one or two boilers: ·Connect the supply voltage to terminals 1­3 ·Loop terminals 11 & 15 & 19 ·Loop terminals 12 & 16 & 20 ·Connection to boiler (example with 2 boilers): - Connect the boiler 1 start signal to terminals 13 & 14 - Connect the boiler 2 start signal to terminals 17 & 18 ·Connect the chimney fan to terminals 4­6 ·Connect the pressure transducer (XTP) to terminals 23­25 21 / 40 3002878-2011-01-14 Pressure-controlled regulation of EXHAUSTO CDT chimney fan 2. 5 User menu 2. 5. 1 Layout of the user menu The user menu consists of a single level and provides access to 4 parameters: Menu Function 1 2 3 4 Setting the required pressure Setting pre-purge period Setting post-purge period Displaying current alarm (see alarm overview page 35) Range Depending on the XTP-range set in menus 151 and 152 0-999 s 0-60 min - When the instructions refer to the menu numbers 1, 2, 3 and 4 it is understood that these numbers refer to the user menus. 2. 5. 2 Operating the user menu Adjust the set point for user menu items 1­4 in the same way as shown in the example in page 11 To operate menu items 1­4, use the buttons as follows: Step 1 2 3 4 5 6 Press. . . Activate the user menu Go to the menu item you wish to edit Edit the menu item selected Adjust the required set point Confirmandsavetherequiredsetpoint Return to operation screen. NB: If you do not press RESET the EBC20 will automatically return to the operation screen after 30 seconds OK and OK and OK RESET You can alwaysundoanaction(thatyouhavenotconfirmedbypressing OK ) and return to the operation screen by pressing Alarms RESET . For alarm handling (menu 4), see page 34. 2. 6 Set-up For setting up the EBC20, see section 1. 6 Set-up, page 11. 22 / 40 3002878-2011-01-14 Pressure-controlled regulation of EXHAUSTO CDT chimney fan 2. 7 Commissioning Commissioning on the EBC20 must be carried out to ensure a correct draft from the system. ! Step 1 Commissioning should be carried out by staff with the appropriate training, and with the authorisation to do so according to local legislation. Do as follows: Action. . . Provisional draft setting (negative pressure): ·Press ·Press OK to go to Menu 1. [. . . ] Automatic reset If menu 25 is set to automatic reset (1), the EBC20 will attempt to reset an alarm every 10 seconds. Manual reset If menu 25 is set to manual reset (2), alarms must be manually reset. In the event of an alarm, undertake the following procedure: Step 1 2 3 4 Action. . . ·Press ) to display the current Check the alarm overview (next page) to identify the alarm number. RESET to reset the alarm* will disappear ·The alarm diode will switch off, and the alarm symbol from the display. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE EXHAUSTO EBC20




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual EXHAUSTO EBC20 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.