User manual EXHAUSTO RS

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual EXHAUSTO RS. We hope that this EXHAUSTO RS user guide will be useful to you.


EXHAUSTO RS : Download the complete user guide (1177 Ko)

Manual abstract: user guide EXHAUSTO RS

Detailed instructions for use are in the User's Guide.

[. . . ] (Two wing screws are also included, to be used where conditions allow). Bad lighting habits can result in problems with soot, chimney fires, etc. All installations must be carried out by competent personnel in accordance with national laws and regulations · The chimney fan must always be operating when the fireplace is in use. [. . . ] Note that there should be a 2-4 mm gap between the brackets and the chimney so as to avoid transmitting vibrations from the fan to the chimney. 3000112-2010-12-13 Before fitting onto a steel chimney: Step 1 Action A flange (C) is used, fitted so that the spigot end sits inside the chimney (D). Place the mineral wool mat (A) on the flange (C) with aluminium foil facing upwards and cut a hole in the mineral wool mat, the hole being the same diameter as the flange hole. Cut the corners of the mineral wool mat, so there is room to fit the vibration dampers (B). If a temperature sensor is to be installed with the chimney fan, cut the aluminium foil on the mineral wool mat to make room for the sensor; this also ensures that the mat sits level on the chimney. Fit the flange to the chimney fan, with the use of vibration dampers supplied with the flange. 3000112-2010-12-13 Fitting the chimney fan onto the chimney Step 1 Action The chimney fan is now ready for mounting. Use the supplied screw and rawl-plug in brick chimney and the self-cutting screw in steel chimney. Then mount the wire through the hole in the base plate and into the wire lock. Tighten the safety wire slightly and tighten the wire lock (2), so that the chimney fan is secured when opened for service and cleaning purposes. The isolation switch should be fitted onto the side of the chimney (3), so it is easily accessible when servicing the fan. The armoured cable should be connected into the underside of the isolator and up into the switch via the coupling. Before starting up, make sure that: · The nuts in the location brackets are tightened (4) · The chimney fan is closed and the screw tightened (5) · the safety wire is clamped to the chimney (6) · The safety wire and the wire lock are tightened (7) · the grommet on the armoured cable is fastened (8) · The end-user is aware of the fact that the chimney fan must always be operating when the fireplace/boiler is in use Any lightning conductor connected to the fan must respect current applicable legislation. Varenumre Isolation switch:: In accordance with the provisions of the EU Machinery Directive* a chimney fan must always have an isolation switch fitted. The isolation switch must comply with national EXHAUSTO GRUNDFOS FAN Project: Grundfos motor wiring standards. 96780829 1250433 87104367 RS012-41 The isolation switch must be ordered seperately, as it is not part of the standard EXHAUSTO 1250102 87104368 RSV012-41 Material: CDT chimney fan delivery. [. . . ] At higher temperatures, though maximum 300°C, the mineral wool mat should be removed and replaced with optional adjusting screws (type RSD) or vibration dampers (type SVD. EXHAUSTO CDT provides a two-year factory warranty on its chimney fans, valid from invoice date. EXHAUSTO CDT reserves the right to introduce changes to these guidelines without prior notice. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE EXHAUSTO RS




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual EXHAUSTO RS will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.