User manual GAI-TRONICS 12578-001 DATASHEET

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual GAI-TRONICS 12578-001. We hope that this GAI-TRONICS 12578-001 user guide will be useful to you.


GAI-TRONICS 12578-001 DATASHEET: Download the complete user guide (122 Ko)

You may also download the following manuals related to this product:

   GAI-TRONICS 12578-001 10-06 (200 ko)

Manual abstract: user guide GAI-TRONICS 12578-001DATASHEET

Detailed instructions for use are in the User's Guide.

[. . . ] DS12578-001 GAI-TRONICS® CORPORATION A HUBBELL COMPANY Model 12578-001 Monitored Input Module (MIM) General Information This data sheet applies to GAI-Tronics Model 12578-001 Monitored Input Module (MIM). The MIM is used to receive inputs from field devices, monitor the integrity of eight input lines for trouble conditions or contact activation, and report these conditions to the 69254 Series or 69440 Series Master Control Unit (MCU). [. . . ] Unlimited (Mode 1) 1 (Mode 2) 1 (Mode 3) Unlimited (Mode 5) Input/output. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Power in Power out RS-485 in RS-485 out 8 field inputs Data communications. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . RS-485 RS485 termination . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . On board when P2 jumper is installed End-of-line device. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 k (Mode 1) 5. 1 k in series with 15 k across contact (Mode 2) 5. 1 k in series with 15 k across contact (Mode 3) None (Mode 5) Field Inputs Mode 1: Contact closure resistance (activated). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 k maximum Open Fault Detection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Minimum 65 k Ground Fault Detection. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Less than 200 to ground Modes 2 and 3: Contact closure resistance (Mode 2: activated/ Mode 3: de-activated) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 k maximum Open fault detection. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Minimum 65 k Ground fault detection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Less than 200 to ground Wire-to-wire short fault detection. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Less than 200 Mode 5: Contact closure resistance. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 900 maximum Limitations: Cable limitations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 100 maximum loop resistance Terminals: Minimum conductor size . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ] -30° C to 70° C (-22° F to 158° F) Humidity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 95% non-condensing relative humidity Approval CE Mark f:\standard ioms - current release\data sheets\ds12578-001. doc 11/10 [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE GAI-TRONICS 12578-001




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual GAI-TRONICS 12578-001 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.