User manual GAI-TRONICS 530-001 LED INSTALLATION

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual GAI-TRONICS 530-001 LED. We hope that this GAI-TRONICS 530-001 LED user guide will be useful to you.


GAI-TRONICS 530-001 LED INSTALLATION: Download the complete user guide (61 Ko)

Manual abstract: user guide GAI-TRONICS 530-001 LEDINSTALLATION

Detailed instructions for use are in the User's Guide.

[. . . ] The glow of the LED tower remains constant for area location and flashes on and off, 240 flashes per minute, when activated by an emergency telephone. The LED strobe is designed for top-of-pole mounting, wall mounting, or surface mounting. The unit is equipped with a ¾-inch NPT female pipe thread in the base; a pipe nipple or conduit with a corresponding thread should be used for mounting the units. For wall or surface mounting, the GAI-Tronics Model 4115A Mounting Assembly Kit is recommended. Research indicates that a small portion of the general population, (approximately 1 in 100, 000) with Photosensitive Epilepsy (PSE) may experience epileptiform seizures upon exposure to certain visual stimuli including lights flashing in excess of 3Hz (180cpm). [. . . ] Model 530-001 LED Strobe Outline telephone and test the unit by pressing the EMERGENCY button. The strobe is only activated by pressing the EMERGENCY button, not the CALL button (if so equipped). NOTE: The LED strobe provides a blue and black wire to activate auxiliary equipment such as signaling devices or camera call-up controls. These wires provide a dry contact closure rated for 2 amps @ 240 V ac, or 2 amps @ 30 V dc, for the duration of the emergency telephone/strobe activation. f:\standard ioms - current release\42004 instr. manuals\42004-395g. doc 06/10 Model 530-001 LED Strobe with Constant-On Feature Pub. 42004-395G Page: 3 of 3 Specifications Operating voltage. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 120 V ac @ 60 Hz Nominal current . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0. 44 amperes NOTE: The rated 0. 44A current at 120 V ac 60 Hz is average during operation of the steady lights or strobing LED. A short duration inrush current as high as 45 amps may be experienced when power is first applied to the strobe. Current limiting and/or current protection devices should be specified accordingly. Rated LED life . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Up to 100, 000 hours Flash rate. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 240 flashes per minute Auxiliary contact maximum rating . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 amps @ 240 V ac 2 amps @ 30 V dc Operating (environment) temperature range. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . -40° C to +66° C (-40° F to +150° F) Environmental. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . NEMA-3R (when mounted with dome upright) Terminations (ac, control, auxiliary contact) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 AWG wire Construction: Base: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Die-cast aluminum (light gray, baked enamel finish) Dome: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Polycarbonate (blue) Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7. 75 H × 8. 25 W inches (196. 85 × 209. 55 mm) Shipping weight . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Mounting. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ¾-14 NPT female Approvals. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . UL/ cUL LED Coil Data Nominal voltage. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 V dc Nominal current . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ] Provided, however, that if the defect complained of is latent and not discoverable within the above warranty periods, every claim arising on account of such latent defect shall be deemed waived unless it is made in writing within a reasonable time after such latent defect is or should have been discovered by Buyer. Limitations / Exclusions. The warranties herein shall not apply to, and GAI-Tronics shall not be responsible for, any damage to the goods or failure of the services supplied hereunder, to the extent caused by Buyer's neglect, failure to follow operational and maintenance procedures provided with the equipment, or the use of technicians not specifically authorized by GAI-Tronics to maintain or service the equipment. THE WARRANTIES AND REMEDIES CONTAINED HEREIN ARE IN LIEU OF AND EXCLUDE ALL OTHER WARRANTIES AND REMEDIES, WHETHER EXPRESS OR IMPLIED BY OPERATION OF LAW OR OTHERWISE, INCLUDING ANY WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Return Policy If the equipment requires service, contact your Regional Service Center for a return authorization number (RA#). Equipment should be shipped prepaid to GAI-Tronics with a return authorization number and a purchase order number. If the equipment is under warranty, repairs or a replacement will be made in accordance with the warranty policy set forth above. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE GAI-TRONICS 530-001 LED




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual GAI-TRONICS 530-001 LED will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.