Detailed instructions for use are in the User's Guide.
[. . . ] These figures, when used in conjunction with the station installation information and cable layout guide, should provide all the information necessary to install additional Page/Party stations. Mohnton, PA 19540 USA 610-777-1374 800-492-1212 Fax: 610-796-5954 VISIT WWW. GAI-TRONICS. COM FOR PRODUCT LITERATURE AND MANUALS
Model 702-002, 732-102, and 733-002 24 V DC Single-Party Amplifier Enclosures
Pub. 42004-147G Page: 2 of 12
In 24-volt systems, plan on several branch lines from the dc source with no more than six stations per branch. Where two or more stations are listed, the assumption is that they are evenly spaced along the cable. [. . . ] Under no circumstances should cable entries be made in the side of the enclosure as this may interfere with the installation of the plug-in amplifier. For specific details including mounting hole dimensions, refer to Figure 1 for the Model 702-002 Indoor Enclosure, Figure 2 for Model 733-002 Weatherproof Non-metallic Enclosure, and Figure 3 for the Model 732-102 Weatherproof Metallic Enclosure. When mounting the enclosure, use caution to avoid damaging the terminal blocks inside. The suggested mounting height for all station enclosures is 54 inches (137 cm) up to the centerline of the enclosure.
Figure 1. Model 702-002 Indoor Enclosure Mounting Details
f:\standard ioms - current release\42004 instr. manuals\42004-147g. doc 11/10
Model 702-002, 732-102, and 733-002 24 V DC Single-Party Amplifier Enclosures
Pub. Model 733-002 Outdoor Non-metallic Enclosure Mounting Details
f:\standard ioms - current release\42004 instr. manuals\42004-147g. doc 11/10
Model 702-002, 732-102, and 733-002 24 V DC Single-Party Amplifier Enclosures
Pub. Model 732-102 Outdoor Enclosure Mounting Details
f:\standard ioms - current release\42004 instr. manuals\42004-147g. doc 11/10
Model 702-002, 732-102, and 733-002 24 V DC Single-Party Amplifier Enclosures
Pub. Follow the wire colors carefully, because the colors correspond to GAI-Tronics 60038 Series cable. The wires must be spade-lugged and connected carefully and completely to the terminal block. An improper termination may diminish station performance.
Local Muting
Figure 7 illustrates local speaker muting when stations are completely assembled and paging operation occurs. Normally, when the station push-to-page button is pressed, the paging speaker connected to that station is silenced (muted) to prevent acoustic feedback to the handset microphone. However, while the handset is in use for party line conversations, the paging speaker is "live" to enable paging calls from other stations. Locate the lugged violet wire attached to terminal point 7 (mute) on the terminal block within the enclosure. After any muting changes are made, unpack the station amplifier and install.
Mutual Muting
In the event that feedback occurs within an area and repositioning of the system speakers does not help, mutual muting may be used to correct this problem. The following steps mutually mutes adjacent amplifiers/handsets within a zone. Connect terminal TB1-7 of the handset station to TB1-7 of the station within the zone that is causing feedback. This is done by using the spare system wire (orange conductor) from within the system cable that runs between the stations.
f:\standard ioms - current release\42004 instr. manuals\42004-147g. doc 11/10
Model 702-002, 732-102, and 733-002 24 V DC Single-Party Amplifier Enclosures
Pub. Wiring Diagram for Model 702-002, 732-102, and 733-002 Enclosures
f:\standard ioms - current release\42004 instr. [. . . ] The applicability of any such third-party warranty will be determined by GAI-Tronics.
Services.
Any services GAI-Tronics provides hereunder, whether directly or through subcontractors, shall be performed in accordance with the standard of care with which such services are normally provided in the industry. If the services fail to meet the applicable industry standard, GAI-Tronics will re-perform such services at no cost to buyer to correct said deficiency to Company's satisfaction provided any and all issues are identified prior to the demobilization of the Contractor's personnel from the work site. Re-performance of services shall be Buyer's sole and exclusive remedy, and in no event shall GAITronics warranty obligations with respect to services exceed 100% of the total cost of the services provided hereunder.
Warranty Periods.
Every claim by Buyer alleging a defect in the goods and/or services provided hereunder shall be deemed waived unless such claim is made in writing within the applicable warranty periods as set forth above. Provided, however, that if the defect complained of is latent and not discoverable within the above warranty periods, every claim arising on account of such latent defect shall be deemed waived unless it is made in writing within a reasonable time after such latent defect is or should have been discovered by Buyer.
Limitations / Exclusions.
The warranties herein shall not apply to, and GAI-Tronics shall not be responsible for, any damage to the goods or failure of the services supplied hereunder, to the extent caused by Buyer's neglect, failure to follow operational and maintenance procedures provided with the equipment, or the use of technicians not specifically authorized by GAI-Tronics to maintain or service the equipment. [. . . ]