User manual GAI-TRONICS ICS HAZARDOUS AREA PAGE-PARTY STATION

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual GAI-TRONICS ICS HAZARDOUS AREA PAGE-PARTY STATION. We hope that this GAI-TRONICS ICS HAZARDOUS AREA PAGE-PARTY STATION user guide will be useful to you.


GAI-TRONICS ICS HAZARDOUS AREA PAGE-PARTY STATION : Download the complete user guide (596 Ko)

Manual abstract: user guide GAI-TRONICS ICS HAZARDOUS AREA PAGE-PARTY STATION

Detailed instructions for use are in the User's Guide.

[. . . ] Pub. : 42004-723L2C GAI-TRONICS ® CORPORATION A HUBBELL COMPANY Industrial Communications System Hazardous Area Page/Party® Station TABLE OF CONTENTS General Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Product Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Features. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Options. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Important Safety Instructions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ] Apply a light coat of Killark "LUBG" lubricant to flange surfaces and close the cover. It may become necessary to re-terminate some or all of the enclosures in a system. If so, strip the wires back to clean copper and connect only one wire to each connector to allow for easier future troubleshooting. NOTE: Refer to the Killark Installation, Operation, and Maintenance Data Sheet enclosed with the unit for additional information. f:\standard ioms - current release\42004 instr. manuals\42004-723l2c. doc 11/10 ICS Hazardous Area Page/Party Station Operation Paging with ADVANCE Head End ® Pub. 42004-723L2C Page: 14 of 28 Paging and party line operation with the ICS SmartSeries option is similar to standard station operation. The main differences are that when the handset pressbar or the headset page switch is pressed, a steady "wait" tone will be heard in the handset/headset earpiece. When the "wait" tone ends, a preannouncement tone, if programmed, will sound, and the operator may place their page. If the system is busy and the page is denied, the user will hear a busy tone in the handset/headset earpiece. Paging without ADVANCE Head End Paging and party line operation will be similar to standard station operation with the addition of an optional pre-announcement tone being generated by the station at the beginning of each page. Station Time-out Features The ICS SmartSeries option supports a page duration limit that sets the maximum duration of each page. If the page is still active when the page duration limit is reached, the page will be terminated. When used without an ADVANCE head end, the page duration limit is fixed at 2 minutes. The ICS SmartSeries option supports an off-hook limit that sets the maximum duration that the station may be kept off hook. If the off-hook limit is reached, the station will be placed electrically on hook. To reset the timeout condition, the handset must be physically placed on hook momentarily. When used without an ADVANCE head end, the off-hook limit is fixed at 8 minutes. f:\standard ioms - current release\42004 instr. manuals\42004-723l2c. doc 11/10 ICS Hazardous Area Page/Party Station ® Pub. 42004-723L2C Page: 15 of 28 VLC General The 69553 Volume Level Control (VLC) PCBA adds the capability of remotely controlling the local speaker volume level. When VLC is activated, a remote device transmits a 50 kHz signal over the page line. The station detects the 50 kHz signal and switches to an alternate speaker volume setting. VLC and SmartSeries options cannot be used in the same station. Features · · · · · Provides an "alternate" speaker volume setting that is activated by receiving a 50 kHz signal on the page line. Allows office or crew quarters speakers to be muted until a high priority message or alarm is broadcast. Adds the ability to provide a relay output (requires RTU option) Figure 10. [. . . ] Normally open (N. O. ) or normally closed (N. C. ) dry contacts End-of-line termination. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 kilohms, or 15 kilohms + 5. 1 kilohms Cable resistance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 100 ohms maximum loop resistance Contact closure resistance. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 kilohm maximum Open fault detection. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE GAI-TRONICS ICS HAZARDOUS AREA PAGE-PARTY STATION




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual GAI-TRONICS ICS HAZARDOUS AREA PAGE-PARTY STATION will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.