If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual GAI-TRONICS IDR1000A DC. We hope that this GAI-TRONICS IDR1000A DC user guide will be useful to you.
Manual abstract: user guide GAI-TRONICS IDR1000A DC
Detailed instructions for use are in the User's Guide.
[. . . ] 43004-005B
GAI-TRONICS® CORPORATION
A HUBBELL COMPANY
IDR1000A DC Remote Desk Set User and Installation Manual
GAI-Tronics Corporation 400 E. Mohnton, PA 19540 USA 610-777-1374 800-492-1212 Fax: 610-796-5954 VISIT WWW. GAI-TRONICS. COM FOR PRODUCT LITERATURE AND MANUALS
CONFIDENTIALITY NOTICE This manual is provided solely as an operational, installation, and maintenance guide and contains sensitive business and technical information which is confidential and proprietary to GAI-Tronics. GAI-Tronics retains all intellectual property and other rights in or to the information contained herein, and such information may only be used in connection with the operation of your GAI-Tronics product or system. This manual may not be disclosed in any form, in whole or in part, directly or indirectly, to any third party. [. . . ] For more information, see the switch setting table on page 7.
Initiating Calls
Before initiating a call, press the MONITOR button to verify that the radio channel is clear. To initiate a call, press the TRANSMIT button or the handset push-to-talk (PTT) pressbar. Always allow a short delay before speaking to allow time for the radio channel to be established. The
TRANSMIT button or handset PTT bar must be held down while talking to the radio user and released to listen. When the transmission is completed, the TRANSMIT LED extinguishes and the desk set returns to
the receive mode.
Receiving Calls
When power is first applied, the desk set is in the receive mode, allowing receive audio to be heard through the speaker or handset. The desk set is always in receive mode unless the user presses the TRANSMIT or IC buttons. The desk set contains an internal or local speaker and a handset speaker, which operate as follows: · · When the handset is in the cradle, or on-hook, receive audio is heard on the local internal speaker. When the handset is off-hook, receive audio is routed to the handset.
Handset Transmit
Using the handset is recommended when the desk set is located in noisy surroundings. Press the handset PTT bar or TRANSMIT button and speak into the handset microphone.
Transmit From Internal Microphone
Use the internal microphone only in low noise environments. Press the TRANSMIT button and speak in the direction of the internal microphone. For the best transmit audio quality, maintain a distance of about 12 to 18 inches from the microphone.
11/10
10
Installation
Planning the Installation
Sample IDR1000A Installation Diagram
Mounting
The desk set can be placed on a desk or mounted vertically on a wall. To wall mount the desk set, remove the four bottom screws from the base and then rotate the base 180°. Reinstall the four screws to the base and rotate the handset hook located on the front of the unit.
FCC Interference Warnings
The FCC requires that manuals pertaining to Class A and Class B computing devices contain warnings about possible interference with local and residential radio and TV reception. Please read these warnings and all safety information in the Foreword section of this manual.
11
11/10
Installation
IDR1000A DC Remote Desk Set Use and Installation Manual
Equipment Required
Test Equipment
· · · ·
RF service monitor AC voltmeter with dB ranges for measuring audio levels #1 Phillips screwdriver 1/8-inch flat blade screwdriver
Documentation
· ·
base station's tone remote adapter manual these installation instructions
Cable Installation Safety Considerations
Interconnecting, communications, and Class 2 dc power cables should be separated from electrical light or other Class I circuits by at least 2 inches. The exception is where Class I wiring or power circuits are run in a raceway, or are metal-sheathed or metal-clad, or are permanently separately from the conductors of the other circuitry by a continuous and firmly fixed nonconductor such as porcelain tubes or flexible tubing in addition to the insulation on the wire. Communications cables and in-building wiring should be listed and marked for the purpose according to NEC Article 800.
Telephone Line Lightning and Over-voltage Protection
For maximum surge and lightning protection, building primary (over-voltage) protectors should be installed at the point where the telephone lines enter the radio equipment building. Primary protectors are usually required by local codes and should be provided by your leased line provider. The IDR1000A DC Remote Desk Set has an over-current phone line fuse (F2) which protects against occasional extreme fault conditions that may get past the primary protectors. If the fuse requires replacement, replace F2 with the same type Bussmann C515S-1. 25 A fuse.
11/10
12
IDR1000A DC Remote Desk Set User and Installation Manual
Installation
Power Connections
Power is supplied to the desk set from a listed ac adapter. Make connections to the main circuit board according to the following table:
TS1 Pin # Function
1 2 3 4 5 6
N/C N/C Line Signal Connection () Line Signal Connection (+) Ground and dc minus or () Power (+)10. 5 to 16 V dc (lead with white dashed line)
Line Connections
To make the required line connections, a cable with a tinned bare leads stripped to about 3/8-inch or pin terminal is necessary. With the housing opened, route the lines through the slot in the housing bottom. Using a small slotted screwdriver, connect the 2-wire line to the terminal block position on the main circuit board labeled LINE 1. [. . . ] The divided output sample (through R178, R179, and R180) is compared to the reference at Q14 which serves as the control element for the series pass transistor Q13.
11/10
20
Troubleshooting
Troubleshooting the IDR1000A DC Remote Desk Set
The following is a list of potential problems you may encounter and possible solutions.
Problem Possible Solution
General problems.
Ensure that there is a valid circuit line path from the desk set to the dc remote adapter. Ensure that the private circuit is balanced by making sure neither side of the telephone line is grounded. Check for a blown fuse and ensure that the desk set is connected to a dc power source.
The desk set will not cause the dc remote adapter to key the radio.
Ensure that the proper dc current magnitude for the dc adapter to key the radio is programmed into the desk set. Ensure that the desk set's output level is set properly, and that the DCLOTL is set in a range of 5 mA to 14 mA into the telephone line.
RX audio is low or distorted.
Ensure that the dc adapter is wired correctly, including the RX audio pair. [. . . ]