User manual GE INTERLOGIX SIMON

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual GE INTERLOGIX SIMON. We hope that this GE INTERLOGIX SIMON user guide will be useful to you.


GE INTERLOGIX SIMON : Download the complete user guide (463 Ko)

Manual abstract: user guide GE INTERLOGIX SIMON

Detailed instructions for use are in the User's Guide.

[. . . ] ) ZZZ*(, QWHUORJL[6HFXULW\FRP 466-1871 Rev F September 2002 *( , QWHUORJL[ Part No: 60-875 Doors & Motion Windows Sensors System Status HOME SECURITY Arm 1/2 3/4 Disarm 5/6 7/8 9/0 CODE Chime Doors Motion Time Sensor On Off HOME CONTROL Bypass Lights EMERGENCY FIRE POLICE AUX Test Weekly Simon Security System User Guide FCC Notices FCC Part 15 Information to the User Changes or modifications not expressly approved by Interlogix Inc. FCC Part 15 Class B This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. [. . . ] Press twice to activate the Latchkey feature. Disarm Press Disarm button once and enter your access code using the NUMERIC buttons to turn security protection off. To subdisarm the system, enter the master access code. Subdisarm Enter your master access code using the NUMERIC buttons while the system is disarmed. The Disarm button on the panel will begin to blink. Emergency Press both EMERGENCY buttons for 3 seconds to cause the system to call a central monitoring station to report a non-medical emergency. Keychain Touchpad For any keypress on the Keychain Touchpad, hold the button until the indicator light blinks. If your installer programmed the Keychain Touchpad with no entry delay, and you armed the system with the Keychain Touchpad, you must disarm your system before entering the home to avoid causing an alarm. If your installer programmed your system for Remote Touchpad Arming, you must enter your home to start the entry delay before you can use your Keychain Touchpad to disarm the system. ! Warning To avoid causing false alarms, check with your installer on how your touchpad options are programmed ! Security system devices cannot compensate you for the loss of life 11 Simon Security System Note For any keypress on the Keychain Touchpad, hold the button until the indicator light blinks. LOCK Press once to arm doors and windows. LOCK Press 3 times to arm doors, windows, Motion Sensors, and to activate the Latchkey option. LOCK and UNLOCK Press both buttons simultaneously for 3 seconds to send a panic (intrusion, silent, or non-medical emergency) alarm to the central monitoring station. Check with the installer to find out how the keychain touchpad panic buttons will operate Note Panic alarms need to be silenced from the panel, a remote handheld touchpad or another keychain touchpad. They cannot be silenced from the same keychain that activated the alarm. UNLOCK Press to disarm your security system. STAR Can be programmed to control a device connected to a universal module. RF Thermostat Operation These guidelines must be followed for RF Thermostat operation: The panel needs to be armed to Level 4 (Doors & Windows and Motion Sensors) to enter Energy Saving Mode. If there are no Motion Sensors in the system, the Motion Sensors button must still be pressed (armed to level 4). Thermostat has to be in Auto Mode for Options 81 and 82 to work correctly. When the panel is disarmed the thermostat returns to normal operating mode. Programming Your System The programming decals are visible when you open the panel cover (see Figure 1. ). Notice the button flow diagrams following the Instruction Summary. 1. Press Down Doors & Motion Windows Sensors Status HOME SECURITY Version 3 Add START MENU Cancel Delete Test * Press for program information. System should be checked by a qualified technician at least every three years. 422-2806 Rev A Arm 1/2 3/4 Disarm 5/6 System 9/0 CODE 7/8 * Light Control * MAIN MENU Sensor/ Access Code Option # Remote * Clock Set 2. Open Cover Doors Special Motion Time Sensor On Off HOME CONTROL Unit # * 4 0 1 Entry/Exit CONTROL MENU Time Delay Sensors 2 3 Note: Hold key or press repeatedly until you hear the desired item. * * - Hours + Chime Lights EMERGENCY Instruction Summary Add Option 5 6 7 8 9 - Minutes + Delete To delete an option or access code Delete FIRE POLICE AUX Test Weekly Option #1: Panel Beeps Option #2: Panel Voice DONE Option #3: Latchkey Time Option #36: Sensor Activated Light Lockout Start Time Option #37: Sensor Activated Light Lockout Stop Time Option #41: Chime Voice Option #42: Speaker Volume Option #43: Pager Phone Number Option #55: Status Beep Volume Add Option # press and follow the voice prompting. Add Access Code Add Access Code DONE Cancel , then If you make a mistake or want to Cancel Press See Note use red numbers to enter 4-digit code. start over press Set Clock Clock Set Hours Minutes See Note Sensor or Phone Test DONE Test Press and follow voice prompts. See Note Press To select a test, press and follow the voice prompting. Figure 1. Opening the panel cover Programming Instructions Use the following instructions to access the programming buttons and programming decals. Simon Security System 12 1. System must be disarmed. Open the Panel Cover by pressing the plastic latch on the top of the panel. When you open the cover you will immediately be prompted by the panel voice to use the numbered keys to enter your ID. Version 3 START MENU Cancel Delete Add Test * Press for program information. System should be checked by a qualified technician at least every three years. 422-2806 Rev A * Light Control * Option # MAIN MENU Sensor/ Access Code Remote * Clock Set Unit # * 4 0 1 Entry/Exit CONTROL MENU Time Delay Sensors 2 3 Note: Hold key or press repeatedly until you hear the desired item. * * - Hours + Instruction Summary Add Option Option #1: Option #2: Option #3: Option #36: Option #37: Option #41: Option #42: Option #43: Option #55: 5 6 7 8 9 - Minutes + Delete To delete an option or access code Delete Panel Beeps Panel Voice DONE Latchkey Time Sensor Activated Light Lockout Start Time Sensor Activated Light Lockout Stop Time Chime Voice Speaker Volume Pager Phone Number Status Beep Volume Add Option # press and follow the voice prompting. Add Access Code Add Access Code DONE Cancel , then If you make a mistake or want to Cancel Press See Note use red numbers to enter 4-digit code. start over press Set Clock Clock Set Hours Minutes See Note Sensor or Phone Test DONE Test Press and follow voice prompts. See Note Press To select a test, press and follow the voice prompting. Note The Master access code is 1-2-3-4 when the panel is shipped. You should change your Master Access Code after your system is installed (see "Access Code"). 2. After pressing the appropriate button on the START MENU, the system voice will prompt you to use the MAIN MENU. The MAIN MENU includes the following buttons: Light Control Option # Sensor/Remote Access Code Press the appropriate button. [. . . ] All alarm systems are subject to possible compromise or failure-to-warn for a variety of reasons. Simon Security System 24 If sirens are not placed within hearing range of persons sleeping, in remote parts of the premises, or if they are placed behind doors or other obstacles. If intruders gain access through unprotected points of entry or areas where sensors have been bypassed. If intruders have the technical means of bypassing, jamming, or disconnecting all or part of the system. If freeze or any environmental sensors are not located in areas where the appropriate condition can be detected. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE GE INTERLOGIX SIMON




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual GE INTERLOGIX SIMON will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.