[. . . ] · Otherwise it will cause fire and electric shock accident.
Do not use the socket if it is loose or damaged. · It may cause fire and electric shock.
Do not operate with wet hands or in damp environment. · It may cause electr ic shock.
4 Room Air Conditioner
Safety Precautions
Close all doors, windows and other outside openings to the room. · The air conditioner must be operated in a enclosed area to be most effective.
Ventilate before operating air conditioner when gas goes out.
ENGLISH
· It may cause explosion, fire, and burn.
If water enters the product, turn off the power switch of the main body of appliance. [. . . ] Set the thermostat control as needed.
12 Room Air Conditioner
Disassembly
Disassembly
Mechanical Parts
1. Pull the top of the front grille away from the cabinet as the top tabs lift out of their slots. Replace the grille by placing the tabs in the slots and push the grille until it snaps into place.
Figure 13
2. Remove 10 screws that secure the cabinet to the base pan and condenser. Remove 2 screws that secure the control panel to control box and base pan. Pull the control board toward yourself.
NOTICE
Figure 15
Controls, wires, and capacitor are now accessible for servicing. Disconnect one housing terminal and 3 wires for the fan motor and compressor. (Refer to wiring diagram on page 19 in this manual or on control box. )
Figure 16
Figure 17
Service Manual 13
Disassembly
Air Handling Parts
4. Remove the clamp springs which are clamped to the boss of fan and turbo fan by hand plier. Re-install by referring to the procedures above.
Figure 20 Figure 19
Figure 21
14 Room Air Conditioner
Disassembly
6. Re-install the components by referring to the removal procedure above. After discharging the unit completely, unbrace the suction and discharge pipes at the compressor connections. (See Figure 25)
Figure 23
Figure 24
Figure 25
Service Manual 15
Disassembly
10. Discharge the capacitor by placing a 20 K resistor across the capacitor terminals. Re-install the components by referring to the removal procedure above. Re-install the components by referring to the removal procedure above.
Figure 27
12. Re-install the components by referring to the removal procedure above.
Figure 28
13. Re-install by referring to procedures above.
Figure 29
Refrigerating Cycle
14. After discharging the refrigerant completely, unbraze the interconnecting tube at the condenser connections. Re-install by referring to the procedures above.
Figure 30
16 Room Air Conditioner
Disassembly
15. After discharging the refrigerant completely, unbraze the interconnecting tube at the evaporator connections. After discharging the refrigerant completely, unbraze the interconnecting tube of the capillary tube. [. . . ] Replace if not within ±10% of manufacturer's rating, replace if shorted, open, or damaged. (If the compressor temperature is high, remove the overload, cool, and retest. ) Check the voltage. (If the compressor temperature is high, remove the overload, cool, and retest. )
Axial Fan
Loose set screw Worn bearings
Compressor will not run, fan motor runs.
Voltage
Wiring
Rocker Switch
Thermostat
Overload
Compressor cycles on overload.
Voltage
Overload
24 Room Air Conditioner
Troubleshooting Guide
COMPLAINT Compressor cycles on overload. If restricted, clean carefully with a vacuum cleaner (do not damage fins) or brush. [. . . ]