If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual LEXICON MC-12 ROOM EQ V5.0. We hope that this LEXICON MC-12 ROOM EQ V5.0 user guide will be useful to you.
Manual abstract: user guide LEXICON MC-12 ROOM EQ V5.0SERIAL COMMUNICATIONS PROTOCOL DEFINITION REV 1-6
Detailed instructions for use are in the User's Guide.
[. . . ] Lexicon MC-12 Serial Communications Protocol
Printed on: 07/13/05
Serial Communications Protocol Definition Project: Lexicon MC-12/MC-12B/MC-12 Room EQ
Updated: July 13, 2005 Software Version 5. 0 Protocol Version: Major rev 1 Minor rev 6
© 2005 Harman Specialty Group All rights reserved.
1 of 106
Lexicon MC-12 Serial Communications Protocol
Printed on: 07/13/05
© 2005 Harman Specialty Group All rights reserved.
2 of 106
Lexicon MC-12 Serial Communications Protocol
Printed on: 07/13/05
Manufactured under license from Dolby Laboratories. "Dolby", "Pro Logic", and the double-D symbol are trademarks of Dolby laboratories.
THX and the THX logo are trademarks of THX Ltd. All rights reserved.
Manufactured under license from Digital Theater Systems, Inc. 5, 451, 942; 5, 956, 674; 5, 974, 380; 5, 978, 762 and other world-wide patents issued and pending. [. . . ] MC-12 users should be using the command described in 7. 3. 47 (MC12_Set_System_Volume).
7. 3. 18. 1 Command Packet Description
Application Header: Command DC_CMD_SET_SYS_VOLUME Data Count 1 Application Data: Data[0] Value 0x21 0x01 nn
7. 3. 18. 2 Data Description
Value: Data Type: Max: Conversion: Unsigned 8 bit integer. 92 0 = -80 dB 92 = +12 dB
7. 3. 18. 3 MC-12 Response
The MC-12 will assign the value from the packet to the system volume.
7. 3. 18. 4 Data Validation
If a value is passed that exceeds the maximum value of that parameter the MC-12 will ignore the command and transmit a DC_NAK command with an error code DC_INVALID_DATA.
7. 3. 19 Set Main Balance (MC-12, MC-1)
Commands MC-12 to set the system balance to the value in this packet. This command has been maintained for backward compatibility with MC-1. In order to maintain backward compatibility, the MC-12 Parameters have been mapped to the MC-1 parameters as described in each Data Description. MC-12 users should be using the command described in 7. 3. 48 (MC12_Set_Main_Balance).
© 2005 Harman Specialty Group All rights reserved.
26 of 106
Lexicon MC-12 Serial Communications Protocol
Printed on: 07/13/05
7. 3. 19. 1 Command Packet Description
Application Header: Command DC_CMD_SET_SYS_BALANCE Data Count 1 Application Data: Data[0] Value
0x22 0x01 nn
7. 3. 19. 2 Data Description
Value: Data Type: Maximum Value: 32 Conversion: Unsigned 8 bit integer. 0 = Left 16 = Center 32 = Right
7. 3. 19. 3 MC-12 Response
The MC-12 will assign the value from the packet to the system balance.
7. 3. 19. 4 Data Validation
If a value is passed that exceeds the maximum value of that parameter the MC-12 will ignore the command and transmit a DC_NAK command with an error code DC_INVALID_DATA.
7. 3. 20 Set Front/Back Balance (MC-12, MC-1)
Commands MC-12 to set the front/back balance to the value in this packet. This command has been maintained for backward compatibility with MC-1. In order to maintain backward compatibility, the MC-12 Parameters have been mapped to the MC-1 parameters as described in each Data Description. MC-12 users should be using the command described in 7. 3. 49 (MC12_Set_Front_Back_Balance).
7. 3. 20. 1 Packet Description
Application Header: Command DC_CMD_SET_FRONT_BACK_BALANCE Data Count 1 Application Data: Data[0] Value 0x23 0x01 nn
7. 3. 20. 2 Data Description
Value: Data Type: Max: Conversion: Unsigned 8 bit integer. 32 0 = Front 16 = Center 32 = Back
7. 3. 20. 3 MC-12 Response
© 2005 Harman Specialty Group All rights reserved.
27 of 106
Lexicon MC-12 Serial Communications Protocol The MC-12 will assign the value from the packet to the front/back balance.
Printed on: 07/13/05
7. 3. 20. 4 Data Validation
If a value is passed that exceeds the maximum value of that parameter the MC-12 will ignore the command and transmit a NAK command with an error code DC_INVALID_DATA.
7. 3. 21 Set Active Effect by Id (MC-12, MC-1)
This command requests the MC-12 to set the active effect to the value in this packet. This command has been maintained for backward compatibility with MC-1. In order to maintain backward compatibility, the MC-12 Parameters have been mapped to the MC-1 parameters as described in each Data Description. MC-12 users should be using the command described in 7. 3. 50 (MC12_Set_Active_Effect_By_Id).
7. 3. 21. 1 Command Packet Description
Application Header: Command DC_CMD_SET_EFFECT Data Count 1 Application Data: Data[0] EffectId 0x24 0x01 nn
7. 3. 21. 2 Data Description
EffectId: Data Type: Unsigned 8 bit integer Definition/Conversion: Appendix I MC-1 to MC-12 Effect ID Map.
7. 3. 21. 3 MC-12 Response
The MC-12 will load the desired effect.
7. 3. 21. 4 Data Validation
If a value is passed that exceeds the maximum value of that parameter the MC-12 will ignore the command and transmit a NAK command with an error code DC_INVALID_DATA.
7. 3. 22 Set Record Input (MC-12, MC-1)
Sets the Record input. This command has been maintained for backward compatibility with MC-1. In order to maintain backward compatibility, the MC-12 Parameters have been mapped to the MC-1 parameters as described in each Data Description. MC-12 users should be using the command described in 7. 3. 51 (MC12_Set_Record_Input).
7. 3. 22. 1 Command Packet Description
© 2005 Harman Specialty Group All rights reserved.
28 of 106
Lexicon MC-12 Serial Communications Protocol Application Header: Command DC_CMD_SET_REC_INPUT Data Count 1 Application Data: Data[0] InputId
Printed on: 07/13/05
0x25 0x01 nn
7. 3. 22. 2 Data Description
InputId: Data Type: Unsigned 8 bit Integer Description/Conversion: Appendix F MC-12 Input Ids
7. 3. 22. 3 MC-12 Response:
If the Input Id is a valid MC-12 input then the MC-12 will make the request Input the active record input.
7. 3. 22. 4 Data Validation:
The InputId must be a valid Input Id. If it is not the MC-12 will respond with a NAK packet and error code DC_INVALID_INPUT. If the input is assigned the MC-12 will respond with an ACK Packet.
7. 3. 23 Clear Record Input (MC-12, MC-1)
Clears or unassigns the Record input. If Record is active, this command will set the Record Input to OFF
7. 3. 23. 1 Packet Description
Application Header: Command DC_CMD_CLEAR_REC_INPUT Data Count 1 Application Data: Data[0] InputId 0x26 0x01 nn
7. 3. 23. 2 Data Description
InputId: This value is not used by MC-12. Data Type: Unsigned 8 bit Integer
7. 3. 23. 3 MC-12 Response
The MC-12 will set the active record input to OFF.
7. 3. 23. 4 Data Validation
The InputId is not used.
7. 3. 24 Set Zone2 Volume (MC-12, MC-1)
Commands MC-12 to set the Zone 2 volume with the value in this packet. This command has been maintained for backward compatibility with MC-1. In order to maintain backward compatibility, the MC-12 Parameters have been mapped to the MC-1 parameters as described in each Data Description. [. . . ] 0x00
Data Count Application Data: Data[0] InputId Data[1]- Data[DataCount-1] InputName
7. 3. 54. 5 Data Description
InputId: Data Type: Definition/Conversion: InputName: Data Type: Max Length: Unsigned 8 bit Integer Appendix F MC-12 Input Ids
Null (0x00) terminated ASCII character string. INPUT_NAME_LENGTH defined in Appendix G Protocol Constants.
© 2005 Harman Specialty Group All rights reserved.
53 of 106
Lexicon MC-12 Serial Communications Protocol
Printed on: 07/13/05
7. 3. 55 MC-12 Set Input Name by Id (MC-12)
Sets an Input Name to the transmitted value for a given input.
7. 3. 55. 1 Command Packet Description
Application Header: Command Data Count Application Data: Data[0] Data[1]-Data[DataCount-1] MC_CMD_SET_INPUT_NAME 0x48 Number of characters in nn InputName + 2 InputId InputName 0 to 7 ch ch ch . . . 0x00
7. 3. 55. 2 Data Description
InputId: Data Type: Unsigned 8 bit Integer Description/Conversion: Appendix F MC-12 Input Ids InputName: Data Type: Max Length:
Null (0x00) terminated ASCII character string. INPUT_NAME_LENGTH defined in Appendix G Protocol Constants.
7. 3. 55. 3 MC-12 Response
MC-12 will copy the InputName to the given input.
7. 3. 55. 4 Data Validation:
The InputId must be a valid Input Id. [. . . ]