User manual MARTIN MAC 600

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual MARTIN MAC 600. We hope that this MARTIN MAC 600 user guide will be useful to you.


MARTIN MAC 600 : Download the complete user guide (816 Ko)

Manual abstract: user guide MARTIN MAC 600

Detailed instructions for use are in the User's Guide.

[. . . ] MAC 600/E user manual © 1997 - 2002 Martin Professional A/S, Denmark. No part of this manual may be reproduced, in any form or by any means, without permission in writing from Martin Professional A/S, Denmark. H section 1 INTRODUCTION About this manual . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Safety precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ] Most of these functions may be performed remotely via the serial link with a Martin MPBB1 or MP-2 uploader. The display can be flipped for easy reading by pressing the [] and [] keys simultaneously. The intensity is adjustable and the display can be set to go out 2 minutes after the last key-press. The DMX or Martin address, depending on the protocol setting, and any error messages are displayed when the MAC 600/E is turned on. Address/ Messages PSET dAdr MAdr TIME Po H RPoH LA H RLAH LSTR RLST AdJ RST L ON LoFF HEAd ALL dIM CYAN MAG YEL COL BS1 BS2 SHUT CAL P OF T OF d OF C OF M OF Y OF PATI SWAP PINV TINV MAN RST L ON LoFF SHUT dIM CYAN MAG YEL COL BS1 dMXL STCO CH 0 . . . . CH13 TSEQ PTSP EFSP MOdE VER CPU FEbA dISP SPEC dISP dINT dLoF dRES ALON FEbA dFSE FACT CUS1 CUS2 CUS3 PATI dFOF BS2 AUTO PAN UPLd TILT ASHT TEMP bASE HEAd FAN PCbT SCUT FTST EFFb TRAC MOdE CAL ETYP Address and protocol selection Protocol selection (PSET): Switch between MART, DMX1, DMX2, DMX3, or DMX4 to enable Martin mode or DMX mode 1, 2, 3, or 4. Martin address (MAdr): Set the Martin address between channel 1 and 31. User Manual 11 Personality settings Personality Pan/tilt speed Path Options Effect (Default settings shaded. ) Optimize movement for speed. * Optimize movement for smoothness. * Map DMX pan control to tilt channel and vice versa. Reverse DMX pan control, right Normal pan control, left FA ST PTSP NORM ON Pan/tilt swap PATI/SWAP OFF ON Pan inverse PATI/PINV OFF ON Tilt inverse PATI/TINV OFF MOd1 Tracking algorithm Tracking samples Effects speed SPEC/TRAC/MOdE Æ right. Normal tilt control, up Æ down Real delta value algorithm Æ left. Absolute delta value algorithm (for most controllers) MOd2 SPEC/TRAC/CAL EFSP 1-10 FAST SAFE ON Tracking samples. Disable DMX reset command. * Lamp strikes automatically within 90 seconds of power on. Effect wheels turn the shortest direction. * Effect wheels always turn same direction. * Shutter "helps" dimmer black out. Optimize effects for speed. * Optimize effects for silence. * Enable pan/tilt position correction system. Select Schiederwerk ballast (MAC 600 E's after S/N 4020700000) Select Mitronic ballast (MAC 600 E's with date-based S/N or before S/N 4020700000) * Setting may be overridden via DMX. See the protocol for details. Display on/off Display intensity DMX lamp off SPEC/dISP OFF SPEC/dINT SPEC/dLOF 10-100 ON OFF ON DMX reset SPEC/dRES OFF ON Automatic lamp on Automatic protocol detection Shortcuts SPEC/ALON OFF ON SPEC/AUTO OFF ON SPEC/SCUT OFF ON Automatic shutter SPEC/ASHT OFF NORM Studio mode MOdE STUd ON Pan/tilt feedback SPEC/FEbA OFF ON Effects feedback SPEC/EFFb OFF REG Fan speed SPEC/FAN FULL Electronic ballast type SCHI SPEC/ETYP MITR 12 MAC 600/E Readouts U s a g e r e a d o u t s ( TIME) Read the total number of power-on hours (Po H), power-on hours since last reset (RPoH), total lamp hours (LA H), lamp hours since last reset (RLAH), total number of lamp strikes (LSTR), and the number of lamp strikes since last reset (RLST). The resettable counters may be used to track overall usage and lamp life. To reset to zero, display the readout and then press [] for 5 seconds. D M X v a l u e r e a d o u t s ( dMXL) Read the DMX start code (STCO) and DMX values received for each channel. This is an easy way to check that the start code is 0 and that the fixture is receiving the expected commands. If the fixture is set to a DMX mode where some or all of the channels between 10 and 13 are not used, the readout on these channels will be N/A. Note: the channel number is 1 less in the readout than it is in the DMX protocol. S o f t w a r e v e r s i o n r e a d o u t s ( VER) Read the version number of the CPU software (CPU), pan/tilt feedback circuit (FEbA), and display module software (dISP). The CPU software version is also displayed for a moment at power up. T e m p e r a t u r e r e a d o u t s ( SPEC/ TEMP) Read temperature in the base (bASE) and head (HEAd) in Celsius. Temperatures below 25° C are shown as -25; temperatures above 100° C are shown as +100. The temperature sensors are calibrated at the factory and adjustment should not be necessary. [. . . ] 750W, 3. 9A @ 230V/50Hz; 750W, 4. 2A @ 208V/60Hz Power factor (PF) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0. 85 Electrical, electronic ballast version · · · Transformer taps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 100/110/120/200/210/220/230/240 @ 50 - 60 Hz Power and current . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 690 W, 3. 2 A @ 230 V / 50 Hz Power factor (PF) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE MARTIN MAC 600




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual MARTIN MAC 600 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.