[. . . ] MAC 600/E
user manual
© 1997 - 2002 Martin Professional A/S, Denmark. No part of this manual may be reproduced, in any form or by any means, without permission in writing from Martin Professional A/S, Denmark. H
section 1
INTRODUCTION
About this manual . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Safety precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ] Most of these functions may be performed remotely via the serial link with a Martin MPBB1 or MP-2 uploader. The display can be flipped for easy reading by pressing the [] and [] keys simultaneously. The intensity is adjustable and the display can be set to go out 2 minutes after the last key-press. The DMX or Martin address, depending on the protocol setting, and any error messages are displayed when the MAC 600/E is turned on. Address/ Messages
PSET
dAdr
MAdr
TIME Po H RPoH LA H RLAH LSTR RLST
AdJ
RST L ON LoFF HEAd
ALL dIM CYAN MAG YEL COL BS1 BS2 SHUT
CAL
P OF T OF d OF C OF M OF Y OF
PATI
SWAP PINV TINV
MAN
RST L ON LoFF SHUT dIM CYAN MAG YEL COL BS1
dMXL
STCO CH 0 . . . . CH13
TSEQ
PTSP
EFSP
MOdE
VER
CPU FEbA dISP
SPEC
dISP dINT dLoF dRES ALON FEbA dFSE
FACT CUS1 CUS2 CUS3
PATI
dFOF BS2 AUTO PAN UPLd TILT ASHT TEMP
bASE HEAd
FAN PCbT SCUT FTST EFFb TRAC
MOdE CAL
ETYP
Address and protocol selection
Protocol selection (PSET): Switch between MART, DMX1, DMX2, DMX3, or DMX4 to enable Martin mode or DMX mode 1, 2, 3, or 4. Martin address (MAdr): Set the Martin address between channel 1 and 31.
User Manual
11
Personality settings
Personality Pan/tilt speed Path Options Effect (Default settings shaded. ) Optimize movement for speed. * Optimize movement for smoothness. * Map DMX pan control to tilt channel and vice versa. Reverse DMX pan control, right Normal pan control, left
FA ST PTSP NORM ON
Pan/tilt swap
PATI/SWAP OFF ON
Pan inverse
PATI/PINV
OFF ON
Tilt inverse PATI/TINV
OFF MOd1
Tracking algorithm Tracking samples Effects speed SPEC/TRAC/MOdE
Æ right. Normal tilt control, up Æ down
Real delta value algorithm
Æ left.
Absolute delta value algorithm (for most controllers)
MOd2
SPEC/TRAC/CAL EFSP
1-10 FAST SAFE ON
Tracking samples. Disable DMX reset command. * Lamp strikes automatically within 90 seconds of power on. Effect wheels turn the shortest direction. * Effect wheels always turn same direction. * Shutter "helps" dimmer black out. Optimize effects for speed. * Optimize effects for silence. * Enable pan/tilt position correction system. Select Schiederwerk ballast (MAC 600 E's after S/N 4020700000) Select Mitronic ballast (MAC 600 E's with date-based S/N or before S/N 4020700000) * Setting may be overridden via DMX. See the protocol for details.
Display on/off Display intensity DMX lamp off
SPEC/dISP
OFF
SPEC/dINT SPEC/dLOF
10-100 ON OFF ON
DMX reset
SPEC/dRES
OFF ON
Automatic lamp on Automatic protocol detection Shortcuts SPEC/ALON
OFF ON
SPEC/AUTO
OFF ON
SPEC/SCUT
OFF ON
Automatic shutter SPEC/ASHT
OFF NORM
Studio mode MOdE
STUd ON
Pan/tilt feedback SPEC/FEbA
OFF ON
Effects feedback SPEC/EFFb
OFF REG
Fan speed SPEC/FAN
FULL
Electronic ballast type
SCHI
SPEC/ETYP
MITR
12
MAC 600/E
Readouts
U s a g e r e a d o u t s ( TIME)
Read the total number of power-on hours (Po H), power-on hours since last reset (RPoH), total lamp hours (LA H), lamp hours since last reset (RLAH), total number of lamp strikes (LSTR), and the number of lamp strikes since last reset (RLST). The resettable counters may be used to track overall usage and lamp life. To reset to zero, display the readout and then press [] for 5 seconds.
D M X v a l u e r e a d o u t s ( dMXL)
Read the DMX start code (STCO) and DMX values received for each channel. This is an easy way to check that the start code is 0 and that the fixture is receiving the expected commands. If the fixture is set to a DMX mode where some or all of the channels between 10 and 13 are not used, the readout on these channels will be N/A. Note: the channel number is 1 less in the readout than it is in the DMX protocol.
S o f t w a r e v e r s i o n r e a d o u t s ( VER)
Read the version number of the CPU software (CPU), pan/tilt feedback circuit (FEbA), and display module software (dISP). The CPU software version is also displayed for a moment at power up.
T e m p e r a t u r e r e a d o u t s ( SPEC/ TEMP)
Read temperature in the base (bASE) and head (HEAd) in Celsius. Temperatures below 25° C are shown as -25; temperatures above 100° C are shown as +100. The temperature sensors are calibrated at the factory and adjustment should not be necessary. [. . . ] 750W, 3. 9A @ 230V/50Hz; 750W, 4. 2A @ 208V/60Hz Power factor (PF) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0. 85
Electrical, electronic ballast version
· · · Transformer taps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 100/110/120/200/210/220/230/240 @ 50 - 60 Hz Power and current . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 690 W, 3. 2 A @ 230 V / 50 Hz Power factor (PF) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ]