User manual NAPCO C 1000 STE DATASHEET

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual NAPCO C 1000 STE. We hope that this NAPCO C 1000 STE user guide will be useful to you.


NAPCO C 1000 STE DATASHEET: Download the complete user guide (226 Ko)

You may also download the following manuals related to this product:

   NAPCO C 1000 STE DATASHEET (470 ko)

Manual abstract: user guide NAPCO C 1000 STEDATASHEET

Detailed instructions for use are in the User's Guide.

[. . . ] C100STE SERIES NAPCO's Adaptive® Dual Microwave/PIR Detectors automatically adjust to their environment, minute by minute, for the ultimate false alarm immunity & reliability Upon installation, a NAPCO Adaptive Microwave/PIR Detector powers up, initialized in the first of its 12 senstivity modes, i. e. , the most sensitive, enabling it to sample prevailing environmental conditions. Faced with hostility or tranquility, the Adaptive detector automatically selects the most appropriate detection mode accordingly, optimizing both intruder catch and stability. Each time the sensors detect a stimulus stong enough to generate a signal, but insufficient in strength to indicate an alarm, the detector will automatically change sensitivity modes, effectively widening the gap between the detected signal and its alarm threshold. [. . . ] This ensures intruder "catch" sensitivity is optimized minute-by-minute, while "phantom" false alarm sources, such as pets/animals, fans, sunlight, HVAC, are simultaneously counteracted. The on-board A to D conversion microprocessor (Analog-to-Digital) analyzes all incoming microwave and PIR detected signals against its built in library of waveform signatures of known false alarm sources, like heaters, fans, blowing drapes/blinds and animals. The product of decades of sensor engineering and expertise, this inherent signal processing intelligence, enables Adaptive® Detectors provides unsurpassed false alarm discrimination the reliability and accuracy will save both time and money. · 12 automatically selected, dynamic Adaptive® detection modes for optimal "intruder catch" and stability. The detector combines the strengths of both heat- and motion-sensitive detection technologies to dually verify alarm conditions for ideal false alarm discrimination. · Active, automatic self-testing of all key components and circuits. The unit will internally generate both a PIR signal and a microwave signal, in intervals of 11- 16 hours, which will fully test both channels independently. Any failure or internal trouble will be reported to the system for quick remedy, avoiding any false sense of security or breach thereof. · Superior RFI-/EFI-/lightning shielded protection Key components and resilient SMD circuitry are electronically-shielded to 30V/ m. This protects the unit's proper performance from nuisance interference due to static discharge, power surges, electric spikes, etc. · Optimized field-of-view with custom-engineered aspheric optics. Napco's fresnel lenses are carefully designed to provide the ideal wide angle lens array and are easily-aimable during installation. Additional field-changeable lenses available: Pet Alley, Barrier and Long Range. Although the unit will adapt to effectively ignore activity/interference beyond the protected area, the detector enables manual, customizable range with a calibrated adjustable potentiometer to fine-tune range during walk-test, if desired. [. . . ] This includes properties of its circuitry and fresnel optics, which include integral extra white light protection, a Napcopioneered innovation. · Compliances: UL, CUL, CE, INCERT, NFA2P, NCP SPECIFICATIONS · Microprocessor: · Mounting: · Output relay: · Relay time: · Alarm Relay: · Operating temperature*: 2K ROM with A-D Converter -10 to +50 degrees C (14 º to 122º F) Wall or corner, 12' (3. 6m) max. ; For pet/animal applications 7' (2. 1m) is recommended. 3 seconds 100mA, 24Vdc with internal 10 ohm current limiting resistor 11 - 16 hrs. · Multi-mode Trouble Output (Open collector) · Self-Test Interval: · Power supply requirements: Filtered 10. 6 to 16VDC nominal with battery backup form the control panel. · Current drain: · Dimensions: · Shipping weight: 28mA (idle/alarm) at 12VDC (nominal) 3. 3"H x 2. 5"W x 1. 9"D (8. 4 x 6. 4 x 4. 8 cm) (HxWxD) 5 oz (142 gm) NAPCO SECURITY GROUP In North America 1-800-645-9445 · 631-842-9400 333 Bayview Avenue, Amityville, New York 11701 USA www. napcosecurity. com International 224 Europa Blvd, Gemini Business Park Warrington WA5 7TN England UK 44 (0) 1925242428 Publicly traded on NASDAQ NSSC NAPCO Product Availability Hotline ­ Call our Stock-Out Hotline at 1-800-645-9330 Press 1, pause then 2. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE NAPCO C 1000 STE




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual NAPCO C 1000 STE will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.