User manual NAPCO CARDACCESS 3000 ARCHITECTURAL AND ENGINEERING SPECIFICATION V2.7

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual NAPCO CARDACCESS 3000. We hope that this NAPCO CARDACCESS 3000 user guide will be useful to you.


NAPCO CARDACCESS 3000 ARCHITECTURAL AND ENGINEERING SPECIFICATION V2.7: Download the complete user guide (714 Ko)

You may also download the following manuals related to this product:

   NAPCO CARDACCESS 3000 DATASHEET (628 ko)

Manual abstract: user guide NAPCO CARDACCESS 3000ARCHITECTURAL AND ENGINEERING SPECIFICATION V2.7

Detailed instructions for use are in the User's Guide.

[. . . ] CardAccess® 3000 Architectural & Engineering Specification Version 2. 7 Continental Access A Division of the Napco Security Group 355 Bayview Avenue Amityville, New York 11701 Phone (631) 842-9400 Fax (631) 842-9135 www. continentalaccess. net ARCHITECTURAL AND ENGINEERING SPECIFICATION, v 2. 7 1 PREFACE The Continental Access CardAccess 3000 Architectural & Engineering Specification is designed to serve as a guide for specifying a Continental Access state of the art integrated Access control, alarm, security, video management system. This document is available free of charge in both printed form and electronic media. CardAccess 3000 CardAccess 3000 will be a full-featured enterprise class access control solution, providing a scalable solution from stand-alone entry level through networked world class enterprise systems. This multi-tiered systems approach will provide for modular expansion and growth as required, and is designed to provide cost-effective system with expansion and functional enhancements. Key Features · A seamless integrated interface for Access Control, Alarm Monitoring, DVR/NVR Interface, Visitor Management Control, Time and Attendance/Payroll Functions, Photo Badging, Import/Export Utilities, Email/SMS Notification, Threat Level Management, Napco Security/Fire Interface and Open API support. 26 to 200 bit card formats plus FIPS 201-1 and NIST 800-116 compliancy. [. . . ] Alerts not requiring operator intervention will be placed directly in the `Events Grid'. The Events grid allows the operator to view the current and past events. The system administrator will be able to force the operators to enter a response for each event the operator processes. The administrator may predefine response messages which the operator may choose from, or the operator can enter his/her own response. The Events grid will contain button controls for sorting and viewing of events. (This can be set per user). ARCHITECTURAL AND ENGINEERING SPECIFICATION, v 2. 7 28 b. Browse Mode: Once the user has logged in, the system shall automatically put the Events grid in Browse. Previous/Next: When sorting on a header there will be two buttons (PREVIOUS) and (NEXT). The Previous button will display the previous day's transactions. Photo/Map: If the Photo/Maps option is enabled, the system should automatically display each user's photo and/or map. Class, Description, Location, Date, Priority, Operator that acknowledged the alert and the time it was acknowledged either through the ACS software or the ACS stand alone map software directly on the Map. Alarm Description: Each alarm point may be defined with a plain text description of up to 40 characters. Alarm Enabling: Alarm points will be enabled during user-definable time schedules and they can be manually silenced from any workstation. Additional Alarms: The system shall also generate alarms for the following: a. Enclosure tampering Access Control Panel communication loss/restore Alarm tampering (supervised) Alarms shall be capable of utilizing events generated by the ACS software. 11. Alarm supervision: When using supervised alarm points, the system shall monitor for "OPEN", SHORT", and "GROUND FAULT" in addition to NORMAL/ABNORMAL conditions. Alarm points will have the capability to output an ASCII text command for CCTV switched interface. This command/output will be user-definable and transmitted on alarm points going into abnormal state, returning to a normal state, or both, and for specified reader events as well. The system operator will be able to choose to assign a floor plan to each alert/ event. The system shall be capable of displaying these floor plans automatically or manually by the operator. If the event is a badge event, in addition to the floor plan, the system will be able to automatically or manually display an image of the badge holder both from the database and live from the CCTV interface. ARCHITECTURAL AND ENGINEERING SPECIFICATION, v 2. 7 29 The system operator will be able to choose to disable the floor plans function in case it is not being used. The maps shall be capable of running without the ACS software running. [. . . ] The contractor shall furnish audiovisual equipment and other training materials and supplies as necessary. Where the contractor presents portions of the course by audiovisual material, copies of the audiovisual material shall be delivered to the owner on the same media as that used during the training session. Up to ____ hours of training shall be provided for in the base contract. 3. 3. General: The contractor shall perform pre-delivery testing, site testing, and adjustment of the completed ACS. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE NAPCO CARDACCESS 3000




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual NAPCO CARDACCESS 3000 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.