User manual NAPCO CICP1300 DATASHEET
DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual NAPCO CICP1300. We hope that this NAPCO CICP1300 user guide will be useful to you.
You may also download the following manuals related to this product:
NAPCO CICP1300 DATASHEET (1347 ko)
Manual abstract: user guide NAPCO CICP1300DATASHEET
Detailed instructions for use are in the User's Guide.
[. . . ] Multiple communication networks (ports) can be connected to the CardAccess® server (or to multiple CardAccess® communication servers) for maximum system expansion and faster communications between the controllers and the server(s). Controller communication choices include: hardwire (repeat or multi-drop mode), LAN/WAN, dial-up or fiber optics for maximum flexibility. Continental Instruments supports RS-232 and RS-422 communication formats for optimal system configuration. [. . . ] The controller's Flash EPROM firmware is easily upgraded when additional features or system enhancements are required. All Continental Instruments' controllers feature extensive multi-stage lightning/transient protection on-board for maximum reliability, even in harsh environments. The Super-Two accepts industry standard Weigand output devices and supports virtually all card/reader technologies. Proximity, Smart, Biometric, Magnetic Stripe, Barcode, Weigand and Keypad readers are easily connected and controlled. The Super-Two can store multiple (up to 10) card bit formats in its internal memory, making it a cost-effective retrofit panel. Supporting multiple bit formats allows existing card populations and readers to remain in place when upgrading to the Super-Two controller. To allow the Super-Two to be the most advanced and most flexible panel to date, Continental Instruments has integrated a Network Interface (optional) to allow the Super-Two to be directly connected to a localarea-network (LAN). Combine that with a total of 2. 5M of memory
Super-Two Capacities
Cards Readers Keypads Reader's w/keypad X-Y matrix keypad interface Standard Memory Memory expansion Network interface Standard Inputs Expanded Inputs Standard Outputs Expanded Outputs Transaction Buffer Time Schedules Access Groups Holidays Power Input Power per reader Accessory Power Battery Backup 7AH Enclosure UL Listing;CUL Listing 20, 000 standard (expandable to 125, 000) 2 (Weigand output) Support for 2 Weigand or X-Y matrix (optional interface required) Simultaneous support for 2 Weigand readers + 2 Weigand keypads or 2 X-Y Matrix keypads Optional (required for X-Y matrix Keypads) 512KB (upgradeable) 2 MB optional (CIC P1300XYB2) plug-in 10-100 base T optional (CICE-PNETBD) 8 Supervised 48 Additional inputs (Supervised) 5 Form C rated at 2. 5A@24VDC/VAC 48 Additional Form C rated at 3A@24VDC/VAC 1000 standard (expandable to145, 000) 255 1, 000 100 120VAC/60Hz to 230VAC/50Hz 100mA@5VDC, 200mA@12VDC 1. 2A@12VDC available for powering strikes, mag-locks and other accessories 4-6 hours(included) Size 20"H x 16" Wand 3. 5" D, 23 lbs. UL 294, CSA C22. 2
Continental Instruments, Division of Napco Security Group · 355 Bayview Ave. , Amityville, NY 11701 (631) 842-9400 · FAX (631) 842-9135 www. cicaccess. com GSA GS-07F-00039H A494A
To allow the Super-Two to be the most advanced and most Superterm-8 Components flexible panel to date, Continental Instruments has integrated Mode Communications Network RS422 Repeat QTY. Description a Network Interface (optional) to allow the Super-TwoUp 4000' controllers on abetween Mode Network. be CICE1940PL-1 to CICP1300 Two (2) reader processing panel (for directly connected to a Polling Line Converter local-area-network. Combine RS422 with 1 that RS422 RS422 RS422 RS232 to RS422 use with CA3000 V 2. 0. 25 and above) Max. 4000' Required server is not located a total of 2. 5M of memory if(requires optional 2M board) and Max. 4000' within 50 512K memory standard upgradable you have a network panel capable of storing 125, 000 cardto 2. 5M total memory capacity with RS232 RS422 up to a 125, 000 card capacity, 8 EOL holders. 4000'
perterm Sup p
perterm Sup p
marterm Sm m
Miniterm i
C
CardAccess 3000 Database and Communications Server
In addition to the rechargable standby battery, each Super-two includes a on-board lithium battery for up to one year of data protection.
supervised alarm inputs, tamper, 5 Relay outputs. Support for on-board LAN adapter, 57. 6Kps, 6 Access Groups per card-holder Unit shipped complete in a lockable steel enclosure including battery standby for memory and system operation UL294 and CUL Listed. [. . . ] Exit devices are typically mounted on the egress side of door.
Required if server is not located within 50 RS232 Max. 4000'
CICE1940PL-1 Polling Line Converter RS232 to RS422
RS422 Repeat Mode Communications Network
4000' max. 4000'
CardAccess 3000 Database and Communications Server
Continental Instruments, A Napco Security Group Company · 355 Bayview Ave. , Amityville, NY 11701 (631) 842-9400 · FAX (631) 842-9135 www. cicaccess. com GSA GS-07F-00039H CardAccess® and CI SQL 3000TM are trademarks of Continental/NAPCO. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE NAPCO CICP1300