[. . . ] GEM-P1664 Series:
8 to 64 Zone Hybrid Hardwire/Wireless Controls
Suitable for EN50131-1 Installations
The GEM-P1664 Series hardwire/ wireless control panel with partitioning ideal to standardize on for both residential & commercial applications!
Features: · 8 to 64 hardwire/wireless zones (including two 2-wire fire zones) · Programmable partitioning for up to four areas · Up to 64 users · Supports full range of reliable NAPCO Wireless crystalcontrol transmitters proven to outperform leading competitive brands in independent tests! [. . . ] FEATURES · 8 Hardwire/Wireless Zones on board · Up to 64 zones with multiplex expansion including 2 two 2-wire fire zones · With multiplexing, can accommodate up to 64 EOL zones (from custom alpha keypads or multiplex modules) · EZ Programming2 More comprehensive, menu-driven programming for all zones plus test timer. · Up to 64 user codes · Up to 4 areas · 3 on-board outputs, up to16 external relay outputs (RM3008s). · Up to 2 NAPCO helically-filtered, crystalcontrol RF receivers · Interior bypass group with programmable automatic interior bypass · 600 event log · Auto Arm · Uses up to 7 of any of the Classic/RP- or KSeries Stay & Away keypads · Programmable telephone line cut supervision with delay · 3 Keypad panics (F, P, A) · Supports all major communicator formats, including: 4/2, SIA, 4+2 and Point ID, plus pager · Backup/double/split reporting; three 20-digit telephone numbers · Dynamic battery test · Reports alarms, restores and troubles by zone. · 2 programmable entry delay times · Chime by zone · 8 EOL burglary zones programmable for area, E/E delay, interior, follower, day zone, chime, fire options, sensor watch, swinger shutdown, cross zoning , etc. · Supports series zone doubling and Loop supervision using double EOL resistors (feature requires use of GEM-EZM4/8 Multiplex Modules) · Multiplex Expandability with GEM EZM4/8 or GEM EZM8 zone expansion modules · Quickloader up/downloading, including unique unattended method · Choice of RF receivers · Partitioning by area · Event log with open/close suppression · Event log viewable at keypad (total log, burglar alarm log, fire alarm log, system trouble log, o/c log) · Cellphone-style keypad programming of zone descriptions ( text) · Programmable 50Hz Clock Setting · Programmable Daylight Savings Time · Programmable Security Bypass (code required for bypass) · Un-Bypassing while disarmed (code required) · Temperature Display at Keypad (-30 to 600C Celsius or -22 to 1400F Fahrenheit) with optional GEM-TEMP64 Indoor/Outdoor Temperature Sensor (Note: Keypad Temperature Display replaces Date on Display) · Programmable High/Low Temperature Alarm Reporting (requires feature enabled; zone 6) · 24 Hour day zone trouble · Programmable security blocking of keypad display messages Informational displays made visible contingent on user's assigned area(s) within system · Programmable Swinger Shutdown (2 or 3 activations selectable) · Zone Anding/Cross Zoning (Grouping of zones in which sequential zone activation is required to generate an alarm)
SPECIFICATIONS · Environmental Classification: Class I (+5C to +40C), Class II (-10C to +40C) and Class III (-25C to +50C) · Input power: 16. 5VAC via Class 2 plug-in 20VA, 40VA or 50VA transformer · Loop voltage: 10-13VDCdc · Loop current: 32. 5mA with 2. 2k ohm EOLR; 5mA for 2-wire fire · Loop resistance: 300 ohm max. ; 50 ohm max for 2-wire fire · Aux & remote power: 12VDC regulated (11. 7 to 12. 5VDC) · Maximum Combined standby current: 650mA · Maximum Alarm current: 2A · Burg. voltage output: 1 · Programmable negative outputs: 2 · Loop response 750ms, programmable 50ms to 2, 000ms POWER (With Type A Power Supply): Grades 1 and 2 Installations with 4AH battery: Maximum combined standby current: 210mA Maximum combined standby current and alarm current: 650mA Grades 1 and 2 installations with 7AHbattery: Maximum combined standby current is: 460mA Maximum combined standby current and alarm current: 500mA Grade 3 installations (requires 7AH battery): Maximum combined standby current is : 110mA Maximum combined standby current and alarm current: 500mA
GEM-TEMP64 Optional temperature sensor, for use with either of the two keypads above, programmable for celsius or fahrenheit. GEM-EZM4/8 Mulitplex Module for 4 to 8 zones expansion (supports series zone doubling and loop supervision using double EOL resistors). GEM-EZM8 8-Zone Mulitplex Module Choice of NAPCO Wireless Receivers & Full Range of NAPCO GEM or Libra Wireless Transmitters (consult manual for selection for your region's frequency): GEM-K4RF Fixed English Language Display Keypad with 32Pt. [. . . ] (Firmware Version 9A+)
333 Bayview Ave. , Amityville, NY, USA 11701 +1. 631. 842. 9400 · +1 (631) 842-2382 fax www. napcosecurity. com NASDAQ: NSSC email: 4-intl-sales@napcosecurity. com
A497 © NAPCO, 6/05 Preliminary specifications subject to change. [. . . ]