User manual NAPCO F64 CODED DATASHEET

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual NAPCO F64 CODED. We hope that this NAPCO F64 CODED user guide will be useful to you.


NAPCO F64 CODED DATASHEET: Download the complete user guide (480 Ko)

Manual abstract: user guide NAPCO F64 CODEDDATASHEET

Detailed instructions for use are in the User's Guide.

[. . . ] Introducing F64 Coded: 8 to 64 zone, 4 area hybrid system with multifunction touchpad ­ up to 64 user codes The F64 Coded smart system from Napco, traditional installs, traditional codes, unconventionally convenient · Talking voice prompts with adjustable volume · Backlit custom alphanumeric LCD with auto sensing dim mode · Built in 4 zone expander, pet PIR and smart 88 db burg/fire siren · 8 to 64 zone partitionable hybrid control panel, supports Gemini Wireless F64 Coded: Intelligent technology made easy to install, easy to use The new, F64 coded touchpads feature traditional digital user codes, smart custom alpha displays & user-friendly talking voice prompts. Deluxe K1VPS model also includes built-in siren and petimmune PIR as well as an on-board 4-zone expansion module to save on equipment, install time & wiring homeruns. The F64 control supports up to 7 touchpads making it ideal F64 Coded Touchpad supports 64 3- to 6-digit user code and offers menu-driven for any installation application. [. . . ] · Pager capability · SIA CP-01 features F64 System Specifications: Input Power: 16. 5-18. 0 VAC via Class 2 Plug-In 20VA, 40VA or 50VA Transformer Loop Current: 3mA; 5mA for 2-wire smoke-detector zones Loop Resistance: 300 Ohm max. ; 50 Ohm for 2-wire smokedetector zones Alarm Voltage Output: 1; Programmable Negative Outputs: 2 Auxiliary Power Output: 11. 7-12. 5 VDC Remote Power Output: 12 VDC regulated Combined Standby Current - See WI1501 UL Listings & Compliances: Household Burglar Alarm System Units: UL1023 Household Fire Warning System Units: UL985 Security Industry Association (SIA) False Alarm Reduction Standard CP-01 F64 Coded Kit & Accessories Ordering information: F-64CODEKIT1 Complete F64 Coded Kit: Coded talking touchpad w/built-in siren, PIR, downloadable 8 to 64 zone hybrid control, plug-in transformer. F-64CODE-K1VPS Additional coded multifunction talking touchpad with built-in siren & PIR and smart display, for use with KIT1 or 2. F-64CODEKIT2, Kit as above, where talking touchpad does not include built in Siren and PIR/occupany sensor. F-64CODE-K1VS Additional coded talking touchpad (NO builtin siren & NO PIR, for use with KIT2 or 1. F-64 System options: PCD-WINDOWS (v5. 6. 1 or higher) Quickloader Downloader Software with PC Preset. F-64TP/TAB Freedom Codefree Multifunction Touchpad w/ PIR & Siren plus deadbolt lock interface. (May be intermixed with F64CODED Touchpads in F64 System (see WI1640B). GEM-TEMP64 Indoor or outdoor temperature sensor displays temperature on touchpad display GEM-EZM4/8 4 to 8 zone EZM multiplex expansion module WI1501 Control Panel Installation Instructions WI1502 Control Panel Programming Instructions WI1629B Installation Addendum WI1640B F64 Touchpad Applications & Configuration Instruction OI318 Freedom System Users Guide TRF11 Transformer, 16. 5Vac/40VA, Class 2 TRF14 Transformer, 16. 5Vac/50VA, Class 2 RBAT4 4Ah 12VA Battery ALL GEMINI WIRELESS DEVICES See back F64 panel flexibility: Gemini Wireless ready and model options Also: Code-free Freedom Touchpads Gemini crystal controlled wireless, proven to outperform the competition New!Low-profile window door transmitter virtually disappears in slim windows GEM-TRANSLP · Ultra compact design 2. 5 H x1W x 0. 5"D; virtually disappears even in new slimline window frames. · Long 5-year life replaceable lithium PL2032 coin cell · Includes internal and external lead (24" mini connector pigtail) · Tamper supervised Wireless window/door transmitters GEM-TRANS2 2-Points · Soft white, compact and low profile · Reversible mounting position for left or right handed operation · Low battery clearly displayed at keypad by zone and transmitter number · Both models include built-in reed switch, magnet, lithium battery, tamper and terminals Recessed wireless window/door transmitter GEM-RTRANS · For recessed use in both windows and doors · Powerful wireless transmitter · White housing, magnet & hole cover · Field-replaceable 5 year battery. Wireless acoustic glass break detector GEM-GB · Superior-immunity to false alarms and excellent detection, even through blinds & light drapes. · Pattern recognition technology - recognizes the actual pattern of glass breaking across the full audio band. · 25' coverage radius with automatic test for easy installation · Enduser hand clap sensor verification · Includes lithium battery, tamper & mounting kit Gemini Wireless Adaptive® dual microwave/PIR GEM-DT · Broad 40' x 40' range · Exclusive Adaptive dual technology for superior false alarm resilience­even from animal/pet activity and optimized catch. · Active self-test of both sensors · 5 interchangeable lens patterns · One button walk-test w auto shut-off · 3 distinct transmissions for tamper alarm and self-test failure · EMI/RFI protected with fully-shielded SMD circuitry · Includes batteries, tamper and mounting screws Wireless pet PIR GEM-PIRPET · Broad 50' x 50' coverage · 40 lb. pet/animal immunity · Signal selective processing · Auto-temperature compensation · EMI/RFI protected with fullyshielded SMD circuitry · Battery-saver feature · Includes lithium batteries & mounting screws. [. . . ] Zero exit/entry countdowns for stress-free, false alarm-free entry/exits combining lock status sensing, motion detection and person-present intelligent technologies (patented). Lock status sensor is direct through-wired from hole to transmitter that communicates with built in receiver in touchpad. Uses any standard deadbolt & deadbolt hole ­ Nothing to touch on the door, either. For complete Code-free F64 system info. see brochure A520 * For intermixing Codefree & Coded Touchpads see configurations - WI640B. ) 1-800-645-9445 · 631-842-9400 · www. napcosecurity. com · email: hotline@napcosecurity. com NASDAQ: NSSC © NAPCO, 2/08. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE NAPCO F64 CODED




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual NAPCO F64 CODED will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.