[. . . ] GEM-C Combination Burglary/Access/ Fire System; UL 864, 9th Edition Isolated commercial Burg. /Access and Fire buses and option for separate burg/access battery backups-- easy calcs. , ideal for AHJs. Uses familiar Quickloader Up/downloading and Gemini style keypads in burglary or fire models. More zones ­ 255, 128 or 32 points More power ­ 7 amps More NAC's ­ Up to 4 on board Built in strobe/horn synch More standby power 32 Amp hour battery capacity Regulated 24V output Regulated Auxiliary Power Supplies Commercial burglary or fire, 12V regulated 2A models (fire shown); or 1. 75A version with plug-in transformer. [. . . ] Report is generated in 3 ways- either remotely (uploaded) or locally through notebook PC or use optional onsite printer. · Isolated backup battery circuits for Burglary and Fire for EZ backup calculation and AHJ compliance; allows dealer to accommodate separate backup times for burg and fire. This allows burg system to drop out after burg battery depletion, while fire system is maintained and extremely stable for extended period. · Full line of UL Commercial Devices for more flexibility & labor-savings Example, Use Gemini Commercial Wireless 2-input module (GEMCWL-WD2) to convert any UL listed device into a UL wireless device, ideal for sprinkler supervisories or for use with pull stations (mounts on top of wall/conduit or in deep sngle-gang box (plastic). Firewolf Fire-Only 24V Intelligent Addressable Fire Configuration, NFPA72 · Main Control board - supports (1) Addressable Fire SLC controller · Fire 4-wire bus for keypads and conventional devices · Power Supply 7A and 4A · RS-232 Printer Module · Fire Keypad with Gemini-style Menu-functionality · Dual Phone Line built in; Synch module built in (System Sensor & Wheelock protocols) NAC Extender - Powerful flexibility · Nearly 7Amps power · 4 onboard NACs with up to 2A ea. , expandable for up to 24 per system · Up to 16Ah total battery capacity · Regulated 24V Aux. power · Distributes synched bell and strobe outputs with built-in module · Monitors AC, battery trouble, tamper and ground fault on Napco bus -or- provides universal FACP support. Gemini-C Intrusion-Only Configuration, Commercial Conventional/ Addressable 255-Zone Burglary System · Supports full line of new GEMC Commercial-rated addressable conventional, or wireless devices simultaneously · 8 to 255 fully-configurable zones, with up to 8 partitions · Familiar Napco Quickloader up/downloading and keypad operation · 32Ah, max. battery capacity Agencies NFPA 72, UL Commercial Fire, UL864 9th Ed. , SIA CP01, UL985. UL household & commercial burg. : UL1610, UL609, UL365, UL1023 (CSFM, FM, MEA listings pending. ) GEMC & FIREWOLF SYSTEM COMPONENTS GEMINI C-SERIES COMMERCIAL COMBINATION CONTROL PANEL Platform supports commercial analog, addressable, wireless or conventional fire or burglary devices. B U R G L AR Y B U S D E V I C E S GEMC-BM or GEMC-BM/PS 4 OR 7 AMP MAIN POWER SUPPLY (GEMC-PS24V7A-R or GEMC-PS24V4A-R) FIRE BUS DEVICES GEMC-F8ZCPIM 8 Fire Zone Expander GEMC-EZM8 ACCESS CONTROL DEVI CES GEMC-RS232 BURGLARY MODULE GEMC-EZM8 SERIAL OUTPUT CONVERTER 2-WIRE 2-WIRE 2-WIRE 2-WIRE 2-WIRE 2-WIRE 2-WIRE GEM-ACM1D GEMC-RECV GEMINI C-SERIES MOTHERBOARD 8 ZONE CONVENTIONAL ZONE EXPANSION MODULE GEMC-RECV WIRELESS RECEIVER WIRELESS RECEIVER 8 ZONE CONVENTIONAL ZONE EXPANSION MODULE (4, MAX. ) 2-WIRE ACCESS CONTROL MODULE (4, MAX. ) + + + SMOKE 2-WIRE (4, MAX. ) (31, MAX. ) GEMC-OUT8 S ­ ­ + SMOKE 2-WIRE ­ + + S ­ ­ SMOKE 2-WIRE ­ + S S ­ ­ SMOKE ­ + S S ­ ­ ­ + + S SMOKE 2-WIRE ­ ­ + + S SMOKE 2-WIRE ­ ­ + + S SMOKE 2-WIRE ­ ­ + + S SMOKE 2-WIRE ­ ­ SMOKE 2-WIRE MUST BE ALL WHEELOCK OR ALL SYSTEM SENSOR + + SMOKE SMOKE MUST BE ALL WHEELOCK OR ALL SYSTEM SENSOR 8 ZONE OUTPUT REMOTE RELAY MODULE + + + + SMOKE GEMC-WL-PIR HORN EOLR 2. 2K GEMC-OUT8 HORN STROBE STROBE HORN HORN HORN STROBE HORN HORN STROBE EOLR 2. 2K 2-WIRE BURG SLC ADDRESSABLE LOOP INTERNET REPORTING MODULE 2-WIRE FIRE SLC ADDRESSABLE LOOP S ­ + ­ + ­ + S ­ + S SMOKE ­ ­ + + S SMOKE ­ ­ + + S SMOKE ­ ­ + + S SMOKE ­ ­ GEMC-WL-SMK 8 ZONE OUTPUT REMOTE RELAY MODULE STROBE EOLR 2. 2K EOLR 2. 2K EOLR 2. 2K EOLR 2. 2K EOLR 2. 2K EOLR 2. 2K } (11, MAX. ) GEMC-BSLC-1PT HORN HORN HORN STROBE STROBE FWC-FSLC-SMK GEMC-RM3008 OUTPUT MODULE SMOKE DETECTOR PIR GEM-2D SINGLE POINT CONVENTIONAL ZONE EXPANDER ADDRESSABLE SMOKE DETECTOR STROBE STROBE HORN HORN HORN 8 ZONES OF CONVENTIONAL 2-WIRE SMOKES PULL STATIONS AND/OR HEAT DETECTORS GEMC-WL-HEAT SECOND DOOR ACCESS CONTROL ACCESSORY GEMC-WL-DT HEAT DETECTOR (ONE FOR EACH GEM-ACM1D) GEMC-RM3008 GEMC-BSLC-DT STROBE STROBE OUTPUT MODULE FWC-FSLC-HEAT STROBE HORN GEMC-FPRINT PRINTER MODULE GEMC-WL-WD2 · 4 ON-BOARD NAC CIRCUITS (CLASS B) (SHOWN) -- or -· 2 ON-BOARD NAC CIRCUITS (CLASS A) Single Fire initiating N/O device DUAL TECH PIR (11, MAX. ) DUAL TECH PIR GEMC-BSLC Burg SLC Mod. devices, 4 on board NACs, 8 partitions (No Loop Isolator/Extender required) 32 Point GEM-C Commercial Combo. Fire/Burg System Kit Similar to above, but with ·24V Panel, 32 Points via commercial addressable, wireless or conventional fire or burg. devices, 2 on board NACs, 8 partitions (No Loop Isolator/Extender required) ·Locking, Medium Red Enclosure, 16 x 17" door, with 14. 25" x 16" base. [. . . ] Application examples: elevator recall, HVAC shutdown, add'l NAC output with power supply Addressable SLC Fire Pull Station Tool for address-programming SLC devices ** Smoke/Heat 6" Base, required for FWC-FSLC- SMK and ­HEAT devices 12VDC Power Supply for Fire Bus, remote supervised. Red 14 x 16" can, connects to 120VAC, supports 32Ah standby batts. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE NAPCO GEMC




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual NAPCO GEMC will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.