User manual OASE FILTOMATIC CWS

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual OASE FILTOMATIC CWS. We hope that this OASE FILTOMATIC CWS user guide will be useful to you.


OASE FILTOMATIC CWS : Download the complete user guide (5066 Ko)

Manual abstract: user guide OASE FILTOMATIC CWS

Detailed instructions for use are in the User's Guide.

[. . . ] Prior to commissioning the unit, please read the instructions of use carefully and fully familiarise yourself with the unit. Ensure that all work with this unit is only carried out in accordance with these instructions. Adhere to the safety information for the correct and safe use of the unit. Please also hand over the operating instructions when passing the unit on to a new owner. [. . . ] For further settings of the FiltoMatic CWS, please read the following Chapter Operation. Fill the quantity of Biokick CWS sufficient for the volume of your pond into the infill opening (20). C1 C2 C3 C4 C5 Display LED displaying the dirty water pump function LED displaying the UVC function Key for manual dirty water pump operation Key for setting a cleaning program for the dirty water pump Key for setting an operating program for the UVC clarifying unit Displays on the controller Display (C1) - Water temperature as standard - Cleaning program as selected - Saved settings - Operating hour counter (h 100) - switches automatically back to temperature display 2 seconds after the last key actuation LED for dirty water pump (C2) - LED flashes green: Partial container drainage - LED is lit green: complete container drainage - LED is lit red: Pump blocked - LED off: Pump not active LED for UVC clarifying unit (C3) - LED is lit blue: UVC clarifying unit is switched on - LED flashes blue in a 8 second interval: The UVC clarifying unit is integrated in the Automatic (AU) operating program - LED flashes in a 1 second interval: The UVC lamp was active for 7500 operating hours; remaining operating life: 500 operating hours - LED flashes twice each half second and once for one second: UVC lamp has reached 8000 operating hours - LED off: UVC clarifying unit is switched off Note: The integrated thermometer permanently measures the water temperature, thereby forming the reference value for the operating programs. The silicone cover protects the controller from soiling; it impairs neither the display reading nor the functionality of the keys. The controller is water tight and can also be operated without the silicone cover. This moisture is negligible and does not affect the controller function. Setting the dirty water pump As the water temperature, the degree of soiling of the pond water greatly depends on the fish population. The dirty water pump pumps out the dirt from the container bottom in intervals. The four different cleaning programs allow to individually adapt the interval for pumping off the dirty water to the degree of soiling. Water temperature Cleaning programs, dirty water pump - Intervals + Intervals INTERVAL 1 INTERVAL 2 INTERVAL 3 INTERVAL 4 off off off off 1 × per day every 2 days every 3 days every 3 days 2 × per day 1 × per day every 2 days every 3 days 4 × per day 2 × per day 1 × per day every 2 days 8 × per day 4 × per day 2 × per day 1 × per day OF off off off off off The pump can then only be actuated manually. Release the INTERVAL (C5) key when the desired cleaning program is displayed. - The setting is saved when the water temperature appears in the display (C1) after a period of approx. Manual pumping out of the dirty water The dirty water can also be removed by pumping manually. Complete container emptying starts when you keep the PUMP (C4) key pressed for longer than 10 seconds. With its UV light, the UVC clarifying unit operating under water removes green algae, as such forming a significant component for pond water cleaning. Depending on the water temperature, the UVC lamp of the UVC clarifying unit is switched on and off in intervals with the AU operating program. In this manner it can be individually adapted to the degree of soiling. The following table shows the operating program AU (Automatic) of the UVC clarifying unit as well as the operating statuses ON and OFF. Water temperature AU < 8 °C 8 °C - 14 °C 15 °C - 21 °C 22 °C UVC lamp is switched on 8h 48 h 72 h 96 h UVC clarifying unit operating programs ON UVC lamp is UVC lamp is switched permanently switched off on 16 h 24 h 24 h 24 h OFF UVC lamp is permanently switched off With Power ON, the operating program AU starts with the OFF interval. The use of Biokick CWS during start-up protects the bacteria cultures in the Biokick CWS. The UVC clarifying unit starts with the ON interval when the AU operating program is manually selected. Release the UVC (C6) key when the desired operating program is displayed. [. . . ] Lift the cleaning components of the dirty water pump (14) and of the UVC clarifying unit (16) out of the inner cover (47)(Figure K). Release the blue engagement hooks (19) on both sides, then remove the inner cover (47) including the foam holders (13) out of the container (Figure S). Slightly lift the foam holder (13) by pulling, press in the blue engagement hooks (48) at the foam holders (13), then take out the foam holders (13) downward (Figure T). Pull the used foam filters (49) over the handle of the foam holder (12) by pulling and insert new foam filters (49) in the opposite order (Figure U). [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE OASE FILTOMATIC CWS




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual OASE FILTOMATIC CWS will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.