User manual RAYMARINE ST 80 MAXIVIEW

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual RAYMARINE ST 80 MAXIVIEW. We hope that this RAYMARINE ST 80 MAXIVIEW user guide will be useful to you.


RAYMARINE ST 80 MAXIVIEW : Download the complete user guide (738 Ko)

Manual abstract: user guide RAYMARINE ST 80 MAXIVIEW

Detailed instructions for use are in the User's Guide.

[. . . ] Distributed by Any reference to Raytheon or RTN in this manual should be interpreted as Raymarine. The names Raytheon and RTN are owned by the Raytheon Company. ST80 Maxiview Operation & Setup Maxiview ST80 Maxiview Operation and Setup 1 Package Contents 1. Display head installation guide 2 ST80 Maxiview Operation and Setup Contents Chapter 1: Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Quick Reference Guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ] Local illumination is used to adjust the lighting of individual display heads -- adjustments will not affect other display heads. System illumination controls the lighting of all display heads in system mode. maxiview LOCAL LAMPS 3 remote Press this key for 1 second from any page to open the illumination display. In local illumination, press this key for 5 second to change to system illumination. In system illumination, press this key for 1 second to return to local illumination. Once the local or system illumination display is active, press this key momentarily to adjust the current setting. Press this key for 1 second to reset the contrast. D2540-1 · Local mode remains active until the power supply is switched off, or the mode is changed to system. · If the LCD illumination is off when adjustment mode is entered, the unit automatically defaults to level 3. · If the LCD is already illuminated the current level is displayed upon entry into adjustment mode. · The display returns to normal operation if there are no further key presses within 8 seconds. 32 ST80 Maxiview Operation and Setup Resetting the Contrast The display contrast can, during local or system illumination adjustment, be reset to the factory default by pressing the page key for 1 second. 2. 10 Data Lost If a chapter that is dependent on a given quantity, e. g. , speed, wind, depth, and this data is lost for more than 8 seconds, a warning screen is displayed until the data is restored. maxiview SPEED CHAPTER NOT AVAILABLE DATA LOST remote WARNING D2560-1 2. 11 Man Overboard and Alarms Man Overboard Man overboard displays are triggered when a man overboard condition exists on SeaTalk. These displays replace the current display until the condition no longer exists. Dead Reckoned MOB maxiview MOBDR 08:30 078 TRUE 1. 2 NM remote Press this key momentarily to display Lat/Lon information if available. D2542-1 ST80 Maxiview Operation and Setup 33 · The dead reckoned screen is displayed providing data is available. · The displayed bearing and range is to the man in the water. Lat/Lon MOB maxiview MOBPOS 08:30 078 TRUE 1. 2 NM remote Press this key momentarily to display dead reckoned information if available. D2543-1 · This screen is displayed upon entry to MOB if dead reckoned information is not available. · Time data may not be shown if the man-overboard data is not sourced from ST80. Incomplete MOB Data If there is insufficient data to provide range, bearing and elapsed time, the following screen is displayed during an MOB condition. maxiview MAN OVER BOARD remote D2544-1 34 ST80 Maxiview Operation and Setup MOB Audible Alarm During an MOB condition, an audible alarm beeps 3 times every thirty seconds. Alarms The Maxiview can be set to respond to all the alarms in the following table or, alternatively, only those identified as specific. Alarm Shallow depth Deep depth Anchor True wind high speed True wind low speed True wind high angle True wind low angle Apparent wind high speed Apparent wind low speed Apparent wind high angle Apparent wind low angle Manual off-course ST80 full watch Pop-Up Displayed SHALLOW WATER DEEP WATER ANCHOR ALARM TRUE WIND SPEED HIGH TRUE WIND SPEED LOW TRUE WIND ANGLE HIGH TRUE WIND ANGLE LOW APPARENT WIND SPEED HIGH APPARENT WIND SPEED LOW APPARENT WIND ANGLE HIGH APPARENT WIND LOW ANGLE OFF COURSE WATCH PERIOD EXPIRED Response All All All All All All All All All All All All Specific The following display is activated when an alarm is received. This display flashes continuously until silenced/turned off or the alarm description page is selected. maxiview remote Press either key momentarily to display the alarm title pop-up or the alarm description page. When the alarm title pop-up is displayed, press either of these keys to silence or turn off the alarm. D2541-1 ST80 Maxiview Operation and Setup 35 The following table lists the alarm status once a silence/turn off key- sequence is performed. Alarm Shallow depth Deep depth Anchor True wind high speed True wind low speed True wind high angle True wind low angle Apparent wind high speed Apparent wind low speed Apparent wind high angle Apparent wind low angle Manual off-course Full ST80 watch Silenced Yes No Yes No No No No No No No No Yes Yes Turned Off No Yes No Yes Yes Yes Yes Yes Yes Yes Yes No No · If an alarm is currently active and an alarm of greater importance is received, the current alarm is replaced with the new alarm. However, the alarm remains on SeaTalk and, if the condition still exists once the current alarm has cleared, will be reinstated. · Silenced alarms will repeat after 30 seconds if the condition persists. Audible Alarms There are basically two types of audible alarm: high priority and low priority. High priority alarms beep continuously while low priority alarms consist of three beeps followed by a 5 second break. · High priority alarms will always override low priority alarms. · Once a high priority alarm has cleared, the previous alarm, if it is still current, will be reactivated. 36 ST80 Maxiview Operation & Setup Chapter 3: Setup This chapter describes how to set and adjust features in the setup menu. These include display formats, response levels for controlling the frequency of screen updates and the thresholds for trend indicators. 3. 1 Entering Setup maxiview DEPTH 36. 5 Press and hold these keys together for 2 seconds to display the user set-up screen. maxiview f FEET remote PRESS " PAGE" TO CONTINUE. . . remote SET- UP Press this key momentarily to advance to user setup. D2499-1 · The Maxiview returns to normal operation after 4 seconds of keypad inactivity. · "SET-UP OFF" replaces the above screen if user setup has been turned off in dealer setup. · Setup can be entered from any normal operating display. ST80 Maxiview Operation & Setup 37 Speed Chapter The following screen is displayed for 2 seconds when entering speed setup. The key sequences shown are only available during this period. maxiview SPEED SET-UP CHAP 1S FOR INSTRUMENT CHAPTER remote Press this key to advance to the next chapter. Press this key for 1 second to return to the instrument chapter. D2500-1 Response Pages Response is used to control the speed at which screens are updated. A high number results in rapid changes of the displayed data while a low number gives a slow but smooth update. 38 ST80 Maxiview Operation & Setup There are two response pages: speed and VMG to wind. [. . . ] If you require a higher degree of security, perhaps all your instruments are mounted in exposed locations, CodeLock can demand that you enter your personal code every time the system is switched on. In this configuration, the code can be entered into any convenient master display head. ST80 Maxiview Operation & Setup 59 4. 2 Analogue Display Heads Automatic CodeLock Systems In an automatically transmitted CodeLock system, the Maxiview reads the code number and starts-up automatically without any user input. Manual CodeLock System In a manually transmitted CodeLock system, the code number is entered via the keypad of any master display head. This code is then sent to all compatible equipment on the same SeaTalk bus. Once this code has been received, the equipment operates in the normal way. 4. 3 Enabling CodeLock The CodeLock security feature can only be switched on from a Masterview display head. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE RAYMARINE ST 80 MAXIVIEW




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual RAYMARINE ST 80 MAXIVIEW will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.