User manual RAYMARINE ST30 DEPTH
DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual RAYMARINE ST30 DEPTH. We hope that this RAYMARINE ST30 DEPTH user guide will be useful to you.
Manual abstract: user guide RAYMARINE ST30 DEPTH
Detailed instructions for use are in the User's Guide.
[. . . ] 8 Chapter 2: Transducer Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 2. 1 Connection to instrument . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 2. 2 Transducer type . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 2. 3 Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ] 23 Return to normal display mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25 Chapter 7: General Specification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
4
ST30 Depth Operation and Installation Handbook
Introduction
Designed for above or below deck installation, the ST30 Depth can be used as a stand-alone master instrument or be set up to repeat information from the SeaTalk bus. The ST30 Depth will display the following information: Water depth Shallow alarm Deep alarm Keel/Waterline offset Minimum depth Illumination level
s tre Me
SH AL L OW EP
DE
UM IM MIN ET FS OF
SP DI
Y LA
DE
PT
H
TM
D625
Chapter 1: Control Head Installation
5
Chapter 1: Control Head Installation
110mm (4. 33in) 42mm (1. 65in) 24mm (1. 0in)
DEEP MINIMUM OFFSET
DISPLAY
Autohelm
DEPTH
D626
1. 1 Siting
The ST30 Depth instrument may be installed above or below deck where it is: easily readable by the helmsman (normally viewed at eye level) protected from physical damage at least 230mm (9in) from a compass at least 500mm (20in) from radio receiving equipment accessible from behind for ease of installation and cable running
Note: To prevent the build-up of moisture the instrument breathes through the back cover. The instrument must, therefore, be mounted where the back cover is protected from direct water.
The case is fitted with a foam gasket to form a water tight seal between the instrument and the installation face.
56mm (2. 20in)
88mm (3. 46in)
SHALLOW
6
ST30 Depth Operation and Installation Handbook
1. 2 Mounting procedure
3
6
5
2
4
1
D627
1 Instrument 2 Fixing studs 3 Thumb nuts 4 Sealing gasket 5 Power supply cable 6 Transducer cable
1. 2.
Make sure the surface to which the instrument (1) is to be mounted is smooth and flat. Use the template (supplied) to mark the centres for the fixing studs (2) and the instrument connector boss.
Note: To allow protective covers to be fitted, adjacent instruments should be sited not less than 6mm (0. 24in) from each other (116mm centre to centre min. ).
3. Using a 60mm (2 3/8in) diameter cutter, drill a location hole for the instrument connector boss. Connect the power supply and transducer cables to the back of the instrument (1). (See relevant installation sections) Screw the two fixing studs (2) into the back cover of the instrument (1). Install the instrument (1) and secure with the thumb nuts (3) provided.
Chapter 1: Control Head Installation
7
1. 3 Power supply (Stand-alone operation)
Caution: The ST30 Depth must only be connected to a 12V supply.
+
+
SEATALK
DE PT H
+
+
5A
+
12V Supply
Red Screen
D627a
For stand-alone operation, use the 1m cable supplied with the instrument. Connect the moulded power plug to either SeaTalk connection on the rear of the instrument. Cut the power cable to length and connect the red wire to the positive 12V terminal and the screen to 0V. Protect with a 5A circuit breaker or fuse.
2.
1. 4 Power supply (SeaTalk system)
If the ST30 Depth is to be connected to a SeaTalk system, use a Standard SeaTalk Extension or Interface cable.
Autohelm
Autohelm
Autohelm
Power Extension Cable
D628
8
ST30 Depth Operation and Installation Handbook
1. 5 Connection to adjacent ST30 instruments
The ST30 Depth is supplied with a daisy-chain cable that allows adjacent ST30 instruments to be linked together. The daisy-chain cable supplies power to adjacent instruments and allows data to be transmitted and received via the SeaTalk bus. The daisy-chain cable plugs into one of the SeaTalk ports on the back cover. Incorrect orientation is not possible as the ports and plugs are matched.
Chapter 2: Transducer Installation
9
Chapter 2: Transducer Installation
2. 1 Connection to instrument
The ST30 Depth transducer is supplied with 10m (32. 5ft) of cable. This cable plugs directly into the back of the instrument.
+ +
SEATALK
DE PT H
+
+
D629
2. 2 Transducer type
The ST30 Depth system is supplied (as standard) with a plastic through hull transducer. This is suitable for use with Glass Reinforced Plastic (GRP), Steel and Aluminium hulls. Wooden hull and transom mount installations require a different type of transducer. Please refer to the following table for details.
Hull material or location Transducer
GRP, Steel, Aluminium Standard through hull plastic Wood Bronze through hull (Z118)
GRP, Steel, Aluminium Retractable through hull (Z120) In hull In hull puck (Z117)
Caution: Plastic through hull transducers must not be used on vessels with wooden hulls.
10
ST30 Depth Operation and Installation Handbook
2. 3 Installation
All depth transducers are supplied with detailed installation and maintenance instructions. These instructions, together with the following notes, should be read thoroughly before attempting to install the transducer.
10 Max
D630
1.
The ST30 Depth transducer must be within 10 of the vertical, forward, aft and athwart ships and within the shaded clear flow areas as shown.
D587
Chapter 2: Transducer Installation
11
2.
Run the transducer cable back to the instrument. [. . . ] For securii, the calibrabon lock/unlock feature is accessed by an extended hold down of the 4 and Dfspfay keys as follows: 1. Press and hold Diiplay and %T for 14 seconds until CAL is displayed for tie second time.
2. I
-6:C
23
3.
Calibrabon lock/unlock is switched on or off usin&?normal access.
Return to normal display mode
Press and hold Display and a After 2 seconds the display returns to depth mode.
6. 5 Master/Repeater display
As It leaves the factory the ST30 Dapth is set
to operate in Master mode. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE RAYMARINE ST30 DEPTH
Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual RAYMARINE ST30 DEPTH will begin.