User manual RCA RP5011

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual RCA RP5011. We hope that this RCA RP5011 user guide will be useful to you.


RCA RP5011 : Download the complete user guide (130 Ko)

Manual abstract: user guide RCA RP5011

Detailed instructions for use are in the User's Guide.

[. . . ] In the space below, record the date and place of purchase: Date of Purchase: Place of Purchase: Service Information This product should be serviced only by those specially trained in appropriate servicing techniques. For instructions on how to obtain service, refer to the warranty included in this Guide. · Please respect the environment!Before throwing any batteries away, consult your distributor who may be able to take them back for specific recycling. Contents General controls--------------2-3 The display-------------------------4 Display messages----------------5 Before you begin---------------6 Setting the time-----------------7 Basic operation-------------------8 Recording mode------------------9 Recording quality / condition -----------------------------------------10 Other functions-----------------11 Erasing file / folder-------------12 Troubleshooting tips----------13 More information--------------14 Warranty-----------------------15-17 EN RISK OF ELECTRIC SHOCK DO NOT OPEN THE LIGHTNING FLASH AND ARROWHEAD WITHIN THE TRIANGLE IS A WA R N I N G S I G N ALERTING YOU OF "DANGEROUS VOLTAGE" INSIDE THE PRODUCT. CAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK, D O N OT R E M OV E C OV E R ( O R BAC K ) . [. . . ] Repeat step 2 and select AVR OFF for de-selection. SP AVR EN 1. AVR (Automatic Voice Recording) This feature allows the unit to sense sound and to record only when you are speaking into the microphone. When dictation stops for about 3 seconds, recording will stop and then start again automatically when you resume dictation. Press RECORD to enter AVR mode. Tip: The first syllable or two may be lost when you start recording because this `sound' is used to turn on the AVR feature. It is a good pratice to make some `sounds' or say a short word to activate the AVR before you begin actual dictation. AVR AVR 9 Recording quality / condition EN Setting Recording Quality You can select between three recording qualities. Definition · SP (Standard Play) - allows about 160 min recording on RP5011. · HQ (High Quality) - allows about 60 min recording on RP5011. Setting Recording Condition You can select between two recording conditions. Definition · CONF (Conference) - in a more open area and recording source is far from the unit. · DICT (Dictation) - in a more enclosed area and recording source is close to the unit. (You may press STOP to exit from further selection. ) Tip: For conferences, to obtain optimum recording quality, place the recorder with the microphone freely exposed to the sound source as close as convenient. A built-in automatic recording level control will set record level for optimum recordings during manual recording. Avoid recording near unwanted noise sources, such as air conditioners or fans. 1. Confirm selection by pressing MENU or STOP. DICT CONF 10 Other functions IntroScan This feature allows playback of the beginning 3 seconds of each file in a folder. Press PLAY to start introductory playback, "SCAn" shows on display. Press STOP to exit Intro Scan sooner. Select folder You can select a specific folder (A/B) for recording. Press STOP to exit to stop mode in the desired folder. EN A A DICT DIC HQ B A DICT DIC HQ Note: You can record up to 99 files in one folder, not exceeding 198 files in total. Play one / play all You can choose to play a specific file or all files in a folder. Cannot erase recorded file(s) · Make sure you follow each step under section "Erasing Selected File" carefully. EN 13 More information EN Precautions for the Unit · Do not use the unit immediately after transportation from a cold place to a warm place; condensation problem may be resulted. Do not store the unit near fire, places with high temperature or places with direct sunlight. Do not operate or store unit in places with frequent static electricity or electrical noise (e. g. Do not expose this appliance to rain or moisture. Precautions for Batteries · If you do not use the unit for more than one month, be sure to remove the batteries to avoid leakage. · When installing batteries, be sure that the polarities are correct. Reversing polarity may cause personal injury and damage to the batteries. [. . . ] This warranty does not include damage to the product resulting from accidents, misuse or leaking batteries. Should your product not perform properly during the warranty period, either: 1. Return it to the selling dealer with proof of purchase for replacement, OR 2. Remove the batteries (where applicable), and pack product complete with accessories in the original carton (or equivalent). [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE RCA RP5011




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual RCA RP5011 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.