User manual ROLAND S-4000 RCS FOR MAC
DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual ROLAND S-4000 RCS. We hope that this ROLAND S-4000 RCS user guide will be useful to you.
You may also download the following manuals related to this product:
ROLAND S-4000 RCS FOR WINDOWS (691 ko)
Manual abstract: user guide ROLAND S-4000 RCSFOR MAC
Detailed instructions for use are in the User's Guide.
[. . . ] 5
Menu. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 S-4000 RCS Window. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Scene Window. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Saving all system settings (Scenes). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ] * Use RS-232C cable contained as accessory of the S-4000 Digital Snake system to connect with USB/Serial
adaptor. If it's necessary to use longer or shorter cable, please purchase RS-232C cable (D-Sub 9pins/male-female/ straight type). It is recommended to use a cable with 15meters length or shorter.
* Please refer to page 88 of the S-4000 owner's manual for pin configurations of the RS-232C REMOTE
connector on the S-4000S and S-4000H. S-4000S
USB cable
RS-232C cable
USB port
USB/Serial adapter
(USA-49W, USA-19HS, etc. ) Female Male REMOTE
or connector S-4000H
USA-28X * In case you are using a USA-28X, RS-422 (mini DIN 8pins Male)/ RS-232C (D-Sub 9pins Male) conversion cable is required.
3
S-4000 RCS User Guide
4. Starting and Shutting down the application
Starting the application 1. Double Click [S-4000 RCS] icon.
The application will be started and the S-4000 RCS window will appear on the desktop.
2. Select the serial port where the S-4000 system is connected.
You have control of the S-4000 system from the S-4000 RCS window of your computer.
In case multiple systems are connected
1. Select system "#1" "#4" in the "Controller" menu and open the S-4000 RCS window. Select a serial port in each of the S-4000 RCS windows and set which S-4000 system will
be controlled from each window.
S-4000S
Select serial port.
S-4000H
S-4000S S-4000H
S-4000S S-4000H
S-4000S S-4000H
S-4000 RCS window
S-4000 system
Shutting down the application 1. Select "Quit S-4000 RCS" from the "S-4000 RCS" menu.
The application will quit.
4
5. Names and Functions
Menu
Menu Bar File Menu New Project Open Project. . . #1#4 Clear Clip Zoom Minimize Bring All to Front Functions Create a new Project. Display all the windows in front.
* For details describing a Scene and Project, please refer to "Saving all system settings (Scenes)" on page 7.
S-4000 RCS Window
1 2 3 4 5 6 7 9 8 10
11 12 13 14 15 16
* The basic operation is the same as it is for the S-4000R Remote Controller. Please refer to the "S-4000R
Remote Controller" section on page 29 of the S-4000 system owner's manual. Display [Recall] button [Store] button [LOCK] button LOCK Indicator Serial port select box
Functions Displays the number of the currently selected memory preset. Recall the settings of the selected memory preset.
* Select the memory preset from the [Recall] pull down menu.
3 4 5 6
Save the settings of the selected memory preset.
* Select the memory preset from the [Store] pull down menu.
Turn on/off the lock function that disables all operations. Select serial port to be assigned to the window.
5
S-4000 RCS User Guide S-4000 RCS Window (continued)
No. Name Functions This shows the status of serial communication between S-4000 RCS and S-4000 system.
Ready: Communication is established REAC Down: No communication --: No signal
7
Serial Communication Indicator
8
[Clip] button Channel No. display Clip Indicator Level Meter [+48V] button [PAD] button Gain display Gain adjust slider Channel Name
Turn off the clip indicator currently lit. Display of stereo link ON: Clip indicator lights in red if audio input level reaches 0dB. Set channel name.
9
10 11 12 13 14 15 16
Scene Window
* Scene Window opens if "New Project" or other menu is selected from the "File" menu. Please refer to "Saving
all system settings (Scenes)" on page 7 regarding operations of Scenes.
1 2 4 3 5
6
No.
1 2 3 4 5
Name Project Name display Scene No. [. . . ] Select a Project to open and click the [Open] button.
The Scene window will open.
4. Click a Scene Number in the Scene List to select a Scene to open and click the [Read]
button.
Scene will be recalled. * It is also possible recall a Scene by double clicking the Scene Number.
Editing a Scene Name 1. Double click the [Name] of the Scene in the Scene Window of the Scene you want to edit. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE ROLAND S-4000 RCS
Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual ROLAND S-4000 RCS will begin.