User manual SPYKER 50

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual SPYKER 50. We hope that this SPYKER 50 user guide will be useful to you.


SPYKER 50 : Download the complete user guide (2264 Ko)

Manual abstract: user guide SPYKER 50

Detailed instructions for use are in the User's Guide.

[. . . ] This warranty gives you specific legal rights, and you may also have other rights which vary from state to state. THIS EXPRESS WARRANTY, WHICH IS APPLICABLE ONLY TO THE ORIGINAL PURCHASE, IS IN LIEU OF AND EXCLUDES ALL OTHER WARRANTIES, WHETHER EXPRESSED OR IMPLIED BY OPERATION OF LAW OR OTHERWISE, INCLUDING ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR PARTICULAR PURPOSE. SPYKER SPREADERS LLC P. O. Broadcast Spreading Handle Assembly 1. In 1988 a new dimension was added to broadcast spreading SPREAD PATTERN CONTROL - a dead center spread pattern equalizer. Spyker's Accuway® spread pattern equalizer solves a complicated problem with a fundamental patented solution. Connect T-handle [46] to center section [45] using (1) bolt [51] & nut [53]. Broadcast spreading is as old as early man. [. . . ] NOTE: Model 58-22 has a black plastic hopper Fine Pellets Mixed Fine Pellets Small Pellets Nitrogen Pellets Med. Secure the handle braces [43] to inside of frame using (2) bolts [51] & nuts [53]. Med. Pellets & Granules Check for proper alignment & then tighten all nuts and bolts at this time. Large Heavy Pellets Read Before Using New Linkage Adjustment Procedure Set regulator dial to 1. Set lever completely to off position. 4 Attach cable clamp (59) to ground prop with 11/ " bolt and nut and finger tighten. The Accuway has two ramps. The front side ramp The back side ramp 2 4 is used to shift the spread pattern to the right. is used to shift the spread pattern to the left. Route cable through clamp, then through swivel and then tighten the cable clamp bolt just enough to allow the cable to slide back and forth easily. Adjust sheath on cable so there is a 1/8" inch of control wire that is visible between the sheath and the edge of the rate gate linkage. Tighten the screw on the cable fastener to anchor the wire, making sure that the rate gate linkage is pushed up against the dial. Trim excess wire behind cable fastener connector when finished (if necessary). 5. 8. NEVER, NEVER, NEVER USE ACCUWAY FRONT AND REAR RAMPS TO SPLIT THE PRODUCT FLOW. With proper adjustment you should be able to achieve a balanced spread pattern. Now you are ready to balance the spread pattern. 2 1 Dial Setting Information The RATE DIAL has 9 numbers with 10 stops between each number, for accurate control of the spreading rate. LINE UP THE DIAL NUMBER WITH THE DIAL INDICATOR. A Note the relationship of the rate gate opening to the front side of the ramp. 12 B 3 Note the relationship of the rate gate opening to the back side of the ramp. 3 Read Before Using Accuway - What It Does Accuway Spread Pattern Equalizer Balances the spread pattern - Bulls Eye - Dead to the Center of the Spreader. Does not change the spread width. CAUTION: Never, never, never use the Accuway to split the product flow from the hopper to the spreading spinner. Exploded View Hopper & Frame Assembly Drive Pin Hole 47 61 38 42 45 49 51 51 43 53 53 54 53 53 56 VARIABLES in product, weather, spreading equipment, spreader operator, etc. , and combinations of variable elements produce VARIABLES in the spread pattern. · VARIABLES include product size, weight, shape, surface finish, hygroscopic or non hygroscopic composition, condition of product (exposure to humidity, temperature, etc. ) VARIABLES include spreading rate (light, medium, heavy). VARIABLES include condition of the spreader end the spreading spinner (product build up on the casting vanes, etc. ) VARIABLES include operator habits, fast or slow walking, tilting spreader forward or backward or operating spreader in a level attitude. 46 50 47 53 53 53 51 · · · · · 45 43 51 62 54 54 48 52 44 63 53 51 39 51 53 40 41 42 37 60 Accuway - How It Works A turn of the spread pattern shifter dial factors the variables. This in turn balances the spread pattern heavier to right or heavier to left as required. Adjustment is very sensitive. (Note the very fine threads on the Equalizer adjustment stem. ) Viewed from the operators position To spread heavier left - move the ramp out. To spread heavier right - move the ramp in. NOTE: hole in hub for drive pin. 50 Series 66 34­22 Tire 34­22 Tire 53 71 55 55 55 71 53 39 58 11 59 4 Exploded View 12 18 13 Read Before Using Now You are Ready to Spread · Spread header strips at the ends of the area OPPOSITE the direction of spreading. This will provide a "turn-around" area, an area to re-align the spreader for the return spread. [. . . ] As insurance against spill damage and spill loss, put material in the hopper with the spreader on a walk, driveway, paper, plastic, etc. Or for added capacity, the inverted bag in the hopper can serve as a capacity extension. Also, an extension hopper, complete with filtering and pulverizing screen, is available from the manufacturer. 72­Screen & Extension Hopper Assembly 73 84 Border Patrol Round Rain Cover 71 9 6 Parts List Item # 1 2 2 3 4 5 6 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 28 29 30 31 32 33 34 35 36 37 38 39 39 40 41 42 42 43 43 44 44 45 45 46 46 47 48 49 50 51 52 Part # SS-94-0006 05-94-0069 05-94-0099 05-94-0068 05-24-1101 05-90-0044 05-94-0042 05-94-0097 05-94-0047 05 94-0045 05-94-0046 05-94-0043 SS-94-0010 SS-96-0003 05-94-0049 SS-94-0012-1 05-97-0019 SS-90-0002 SS-90-0001 SS-92-0002 SS-94-0009 SS-94-0007 05-34-2210 05-34-2204 SS-90-0010 SS-94-0018 SL-HP-1045 SS-94-0014 05-94-0053 05-97-0009 05-54-0004 05-90-0014 05-94-0033 05-94-0035 05-94-0034 05-90-0013-R 05-98-0094 05-98-0095 05-94-0036 05-92-0004 05-44-2205 05-24-1030 05-28-3030 05-24-1050 99-50-1081 05-94-0028 05-94-0053 05-24-1040 05-28-3040 05-24-1120 05-28-3220 SL-HP-1015 05-28-3015 05-24-1010 05-28-3011 SS-94-0013 05-98-0048-1 05-90-0042 05-91-0008 SS-90-0012 05-90-0054 Quantity 1 1 1 1 1 1 2 2 1 1 1 1 1 1 1 1 1 2 1 2 1 1 1 1 1 2 1 4 2 1 1 1 1 1 1 1 1 2 2 1 1 1 1 1 2 2 2 2 2 1 1 1 1 1 1 2 1 2 2 6 1 Description Dial Dial Mount (Stainless Hopper) Dial Mount (Plastic Hopper) Rate Gate Rate Gate Linkage Cable Fastener Double Track Rate Gate Guides (Stainless Hopper) Double Track Rate Gate Guides (Plastic Hopper) Jamb Nut AccuwayTM Adjustment Screw AccuwayTM Adjustment Nut Diffuser Bevel Gear (Model 34-22) Nylon Rotary Agitator Wire Spinner Cam Extension Spreading Spinner Spinner Shaft (Model 34-22) Roll Pin Roll Pin Felt Washer Pinion Gear (Model 34-22) Nylon Hopper Bottom Bearing Axle (Model 34-22) Axle, Gear, Spinner, Shaft Assy (Model 34-22) Roll Pin Drive Wheel (Model 34-22) Hub Cap (Model 34-22) Gear Box Covers W/Retainer (Model 34-22) Gear Box Clamp Rings (Model 34-22) Axle Bushing (Model 34-22) Spinner Shaft (Stainless) Spinner Shaft (Plastic) Cotter Pin/Bevel Gear Bevel Gear (Metal) Gear Support Pinion Gear (Metal) Shaft Collar 1/8 x 9/6 O Ring 1/8 x 13/16 O Ring Gear Box Covers 5/8" Washer at Wheel Hopper-S. S. Axle Cotter Pin (Idle Wheel) Axle Bushing (All Models Except 34-22) Axle Bushing/34-22 Only Handle Brace Painted Handle Brace S. S. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE SPYKER 50




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual SPYKER 50 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.