User manual TEXAS INSTRUMENTS TUSB8040 DATA MANUAL 09-2010

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual TEXAS INSTRUMENTS TUSB8040. We hope that this TEXAS INSTRUMENTS TUSB8040 user guide will be useful to you.


TEXAS INSTRUMENTS TUSB8040 DATA MANUAL 09-2010: Download the complete user guide (174 Ko)

You may also download the following manuals related to this product:

   TEXAS INSTRUMENTS TUSB8040 DATA MANUAL (236 ko)
   TEXAS INSTRUMENTS TUSB8040 DATA MANUAL REV 01-2011 (176 ko)
   TEXAS INSTRUMENTS TUSB8040 USB 3.0 FOUR PORT HUB DATA MANUAL 09-2010 (225 ko)

Manual abstract: user guide TEXAS INSTRUMENTS TUSB8040DATA MANUAL 09-2010

Detailed instructions for use are in the User's Guide.

[. . . ] TUSB8040 USB 3. 0 Four Port Hub Data Manual PRODUCTION DATA information is current as of publication date. Products conform to specifications per the terms of the Texas Instruments standard warranty. Production processing does not necessarily include testing of all parameters. Literature Number: SLLSE42 September 2010 TUSB8040 SLLSE42 ­ SEPTEMBER 2010 www. ti. com Contents 1 2 3 4 5 6 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 1. 1 Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ] 0 = SuperSpeed upstream port not suspended 1= SuperSpeed upstream port suspended Can be left unconnected. The terminal is to indicate the connection status of the upstream port as documented below: 0 = Hub in low/full speed mode 1 = Hub in high-speed mode Can be left unconnected. The terminal is to indicate the connection status of the upstream port as documented below: 0 = Hub not in SuperSpeed mode 1 = Hub in SuperSpeed mode Can be left unconnected. The value of the terminal is sampled at the de-assertion of reset to set the power switch control follows: 0 = Full power management supported 1 = Full Power management not supported When SMBus mode is enabled using SMBUSz, this terminal sets the value of the SMBus slave address bit 1. This terminal should be pulled up or down using an external resistor and should not be left unconnected. SS_SUSPEND O 25 HS O 22 SS O 23 FULLPWRMGMTz_ SMBA1 I, PU 41 Copyright © 2010, Texas Instruments Incorporated PIN DESCRIPTIONS Submit Documentation Feedback Product Folder Link(s): TUSB8040 11 TUSB8040 SLLSE42 ­ SEPTEMBER 2010 www. ti. com 2. 6 Power Signals Table 2-6. 4, 19, 21, 38, 43, 58 68, 80, 77, 72 1, 5, 10, 11, 16, 20, 26, 32, 37, 42, 46, 51, 52, 57, 61, 62, 67, 71 81 3. 3-V power rail DESCRIPTION VDD11 P 1. 1-V power rail VSS G Ground, Power Pad 12 PIN DESCRIPTIONS Submit Documentation Feedback Product Folder Link(s): TUSB8040 Copyright © 2010, Texas Instruments Incorporated TUSB8040 www. ti. com SLLSE42 ­ SEPTEMBER 2010 3 FUNCTIONAL DESCRIPTION Table 3-1. TUSB8040 Register Map BYTE ADDRESS 00h 01h 02h 03h 04h 05h 06h 07h 08h 09h-0Fh 10h-1Fh 20h-21h 22h 23h 24h 25h-2Fh 30h-4Fh 50h-8Fh 90h-CFh D0-F7h F8h F9-FFh CONTENTS ROM Signature (55h) Vendor ID LSB Vendor ID MSB Product ID LSB Product ID MSB Device Configuration Register Battery Charging Support Register Device Removable Configuration Register Port Used Configuration Register Reserved UUID Byte [0:15] LangID Byte [1:0] Serial Number String Length Manufacturer String Length Product String Length Reserved Serial Number String Byte [31:0] Manufacturer String Byte [63:0] Product String Byte [63:0] Reserved Device Status and Command Register Reserved 3. 1 I2C EEPROM Operation The TUSB8040 supports a single-master, standard mode (100 Kbit/s) connection to a dedicated I2C EEPROM when the I2C interface mode is enabled. In I2C mode, the TUSB8040 reads the contents of the EEPROM at bus address 1010000b using 7-bit addressing starting at address 0. If the value of the EEPROM contents at byte 00h equals 55h, the TUSB8040 loads the configuration registers according to the EEPROM map. If the first byte is not 55h, the TUSB8040 exits the I2C mode and continues execution with the default values in the configuration registers. The hub will not connect on the upstream port until the configuration is completed. The requirement for data in those addresses is dependent on the options configured in the Device Configuration and Phy Custom Configuration registers. For details on I2C operation refer to the UM10204 I2C-bus Specification and User Manual. 3. 2 SMBus Slave Operation When the SMBus interface mode is enabled, the TUSB8040 supports read block and write block protocols as a slave-only SMBus device with a slave address of 1000 11xy, where · x is the state of FULLPWRMGMTz_SMBA1 at reset, and · y indicates read (logic 1) or write (logic 0) access. If the TUSB8040 is addressed by a host using an unsupported protocol it does not respond. The TUSB8040 waits indefinitely for configuration by the SMBus host and does not connect on the upstream port until the SMBus host indicates configuration is complete by clearing the CFG_ACTIVE bit. For details on SMBus requirements refer to the System Management Bus Specification. Copyright © 2010, Texas Instruments Incorporated FUNCTIONAL DESCRIPTION Submit Documentation Feedback Product Folder Link(s): TUSB8040 13 TUSB8040 SLLSE42 ­ SEPTEMBER 2010 www. ti. com 3. 3 Configuration Registers The internal configuration registers are accessed on byte boundaries. The configuration register values are loaded with defaults but can be over-written when the TUSB8040 is in I2C or SMBus mode. 3. 3. 1 ROM Signature Register Table 3-2. RESET STATE 7 0 6 0 5 0 4 0 3 0 2 0 1 0 0 0 Table 3-3. Bit Descriptions ­ ROM Signature Register BIT 7:0 FIELD NAME romSignature ACCESS RW DESCRIPTION ROM Signature Register. This register is used by the TUSB8040 in I2C mode to validate the attached EEPROM has been programmed. The first byte of the EEPROM is compared to the mask 55h and if not a match, the TUSB8040 aborts the EEPROM load and executes with the register defaults. 3. 3. 2 Vendor ID LSB Register Table 3-4. RESET STATE 7 0 6 1 5 0 4 1 3 0 2 0 1 0 0 1 Table 3-5. [. . . ] Expose to absolute-maximum-rated conditions for extended periods may affect device reliability 6. 2 RECOMMENDED OPERATING CONDITIONS MIN NOM 3. 3 1. 100 25 25 MAX 3. 6 1. 155 85 105 UNIT V °C °C over operating free-air temperature range (unless otherwise noted) VDD33 VDD11 TA TJ 3 1. 045 -40 -40 Supply voltage Operating free-air temperature range Operating junction temperature range 6. 3 HUB INPUT SUPPLY CURRENT PARAMETER CONDITION Normal Operation: US: SuperSpeed and high-speed, DS: 4 ports actively transmitting data at SuperSpeed (1) Normal Operation: US: SuperSpeed and High-speed, DS: no DS connections (1) VDD11 (1) Normal Operation: US: High-Speed, DS: 4 ports actively transmit-ting data at high-speed Normal Operation: US: High-Speed, 4 ports connected at high-speed and idle Normal Operation: US: High-Speed, DS: no DS connections Normal Operation: US: SuperSpeed and high-speed, DS: 4 ports actively transmitting data at SuperSpeed Normal Operation: US: SuperSpeed and High-speed, DS: no DS connections VDD33 Normal Operation: US: High-Speed, DS: 4 ports actively transmit-ting data at high-speed Normal Operation: US: High-Speed, 4 ports connected at high-speed and idle Normal Operation: US: High-Speed, DS: no DS connections MIN 760 480 360 TBD 335 105 105 105 TBD 105 TYP 830 540 400 TBD 375 120 120 120 TBD 120 MAX 900 600 440 TBD 415 135 135 135 TBD 135 mA mA UNIT over operating free-air temperature range (unless otherwise noted) IDD Supply current (1) Current consumption was measured at VDD11 = 1. 2 V since preliminary devices (marked as PTUSB8040) require a core voltage of 1. 2 V. Copyright © 2010, Texas Instruments Incorporated ELECTRICAL SPECIFICATIONS (PRELIMINARY DATA) Submit Documentation Feedback Product Folder Link(s): TUSB8040 23 IMPORTANT NOTICE Texas Instruments Incorporated and its subsidiaries (TI) reserve the right to make corrections, modifications, enhancements, improvements, and other changes to its products and services at any time and to discontinue any product or service without notice. Customers should obtain the latest relevant information before placing orders and should verify that such information is current and complete. All products are sold subject to TI's terms and conditions of sale supplied at the time of order acknowledgment. TI warrants performance of its hardware products to the specifications applicable at the time of sale in accordance with TI's standard warranty. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE TEXAS INSTRUMENTS TUSB8040




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual TEXAS INSTRUMENTS TUSB8040 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.