If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual TJERNLUND VH1-3,4 VENT HOODS 8504027 REV 3 1098. We hope that this TJERNLUND VH1-3,4 VENT HOODS 8504027 REV 3 1098 user guide will be useful to you.
Manual abstract: user guide TJERNLUND VH1-3,4 VENT HOODS 8504027 REV 3 1098
Detailed instructions for use are in the User's Guide.
[. . . ] A vent system incorporating a Tjernlund VH1 Series vent hood should not exceed 550o F. Termination of a sidewall vent system with a device other than the Tjernlund VH1 vent hood could affect system performance and result in a possible safety hazard. Plan the vent system layout to avoid the possibility of accidental contact with concealed wiring or plumbing inside walls. [. . . ] Slide the Vent Hood through the opening and fasten to exterior wall using provided screws. Once Power Venter is completely installed and secured, apply a bead of exterior rated caulk between Vent Hood flange and exterior of building.
MAINTENANCE The vent system must be inspected regularly. Screened opening of the vent hood should be free from foreign material and cleaned as necessary. Structural integrity of the vent hood should be maintained so as not to reduce vent discharge opening. Check all vent system connections for leakage and re-seal where needed. If any vent pipe shows signs of deterioration, replace immediately and check new connections for possible leaks. Re-seal with high-temperature silicone sealant or metal tape to prevent flue gas leakage.
TJERNLUND LIMITED ONE YEAR WARRANTY Tjernlund Products, Inc. warrants to the original purchaser of this product that the product will be free from defects due to faulty material or workmanship for a period of (1) year from the date of original purchase or delivery to the original purchaser, whichever is earlier. Remedies under this warranty are limited to repairing or replacing, at our option, any product which shall, within the above stated warranty period, be returned to Tjernlund Products, Inc. THERE ARE NO WARRANTIES WHICH EXTEND BEYOND THE DESCRIPTION ON THE FACE HEREOF, AND TJERNLUND PRODUCTS, INC. EXPRESSLY DISCLAIMS LIABILITY FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES ARISING FROM THE USE OF THIS PRODUCT. THIS WARRANTY IS IN LIEU OF ALL OTHER EXPRESS WARRANTIES AND NO AGENT IS AUTHORIZED TO ASSUME FOR US ANY LIABILITY ADDITIONAL TO THOSE SET FORTH IN THIS LIMITED WARRANTY. IMPLIED WARRANTIES ARE LIMITED TO THE STATED DURATION OF THIS LIMITED WARRANTY. Some states do not allow limitation on how long an implied warranty lasts, so that limitation may may not apply to you. [. . . ] The drill bit must be long enough to penetrate to the building exterior. Attach the template to the building exterior aligning the pilot holes on the template with the pilot holes drilled in step 3. Using a reciprocating saw, cut an opening through the building siding, wall board, etc. , following the appropriate lines of the template. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE TJERNLUND VH1-3,4 VENT HOODS 8504027 REV 3 1098